In field retrieval, the amplitude and phase of the generalized pupil function for an optical system are estimated from multiple defocused measurements of the system point-spread function. A baseline field reconstruction algorithm optimizing a data consistency metric is described. Additionally, two metrics specifically designed to incorporate a priori knowledge about pupil amplitude for hard-edged and uniformly illuminated aperture systems are given. Experimental results demonstrate the benefit of using these amplitude metrics in addition to the baseline metric. (C) 2009 Optical Society of America