PATENT FORAMEN OVALE: PIVOTAL ROLE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE INDICATIONS FOR CLOSURE, ASSESSMENT OF VARYING ANATOMIES AND POST-PROCEDURE FOLLOW-UP

被引:17
|
作者
Vitarelli, Antonio [1 ]
机构
[1] Sapienza Univ, Dept Cardiol, Rome, Italy
关键词
Transesophageal echocardiography; Patent foramen ovale; Device closure; ATRIAL SEPTAL-DEFECT; TO-LEFT SHUNT; TRANSCATHETER CLOSURE; INFECTIVE ENDOCARDITIS; PERCUTANEOUS CLOSURE; CRYPTOGENIC STROKE; DEVICE CLOSURE; VENA-CAVA; CONTRAST; RISK;
D O I
10.1016/j.ultrasmedbio.2019.04.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Patent foramen ovale (PFO) is present in 15%-30% of the general population and has been associated with various pathologic states, including cryptogenic stroke, platypnea-orthodeoxia syndrome, decompression sickness and migraine with auras. Transesophageal echocardiography (TEE) has a major role in the diagnostic evaluation of PFO, as well as in the post-procedural assessment after transcatheter closure. The goals of this article were to synthesize the echocardiographic transesophageal techniques required for accurate PFO diagnosis and careful anatomic assessment of its anatomic variants, to focus TEE indications for device closure as complementary to clinical indications and to assess the role of TEE in the post-procedure follow-up. (C) 2019 The Author(s). Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1882 / 1895
页数:14
相关论文
共 33 条
  • [31] Transcatheter closure of patent foramen ovale for the secondary prevention of decompression illness in professional divers: a single-centre experience with long-term follow-up
    Henzel, Jan
    Rudzinski, Piotr N.
    Klopotowski, Mariusz
    Konka, Marek
    Dzielinska, Zofia
    Demkow, Marcin
    KARDIOLOGIA POLSKA, 2018, 76 (01) : 153 - 157
  • [32] Patent foramen ovale closure in recreational divers: effect on decompression illness and ischaemic brain lesions during long-term follow-up
    Billinger, Michael
    Zbinden, Rainer
    Mordasini, Raffaela
    Windecker, Stephan
    Schwerzmann, Markus
    Meier, Bernhard
    Seiler, Christian
    HEART, 2011, 97 (23) : 1932 - 1937
  • [33] Transcatheter closure of patent foramen ovale (PFO) in patients with paradoxical embolism - Periprocedural safety and mid-term follow-up results of three different device occluder systems
    Braun, M
    Gliech, V
    Boscheri, A
    Schoen, S
    Gahn, G
    Reichmann, H
    Haass, M
    Schraeder, R
    Strasser, RH
    EUROPEAN HEART JOURNAL, 2004, 25 (05) : 424 - 430