Improving the stability of Pb2+ ion-selective electrodes by using 3D polyaniline nanowire arrays as the inner solid-contact transducer

被引:25
|
作者
Zeng, Xianghua [1 ,2 ,3 ]
Liu, Yanhua [1 ,2 ,3 ]
Jiang, Xiaohui [1 ,2 ,3 ]
Waterhouse, Geoffrey I. N. [4 ]
Zhang, Zhiming [1 ,2 ,3 ]
Yu, Liangmin [1 ,2 ,3 ]
机构
[1] Ocean Univ China, Minist Educ, Frontiers Sci Ctr Deep Ocean Multi Spheres & Eart, Qingdao 266100, Peoples R China
[2] Ocean Univ China, Minist Educ, Key Lab Marine Chem Theory & Technol, Qingdao 266100, Peoples R China
[3] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Marine Corros & Protect, Qingdao 266100, Peoples R China
[4] Univ Auckland, Sch Chem Sci, Auckland 1142, New Zealand
关键词
Ion-selective electrode; Pb2+ detection; Three-dimensional nanomaterials; Polyaniline; Solid contact; POTENTIAL STABILITY; SURFACE-AREA; POLYMER; CARBON; SENSOR; FILM; CONSTRUCTION; PERFORMANCE; NANOTUBES; SILVER;
D O I
10.1016/j.electacta.2021.138414
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Polyaniline nanowire arrays (PANI-NWA) were synthesized by electrochemical deposition, then successfully applied as the ion-to-electron transducer in ion selective electrodes (ISEs) for the detection of aqueous Pb2+ ions. When used as the solid-contact layer in Pb2+-ISEs, the PANI-NWA delivered a high capacitance and low impedance as measured by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), respectively, thus delivering efficient ion-to-electron transfer. Owing to the open structure of the nanowire arrays, Pb2+ ions can able to easily penetrate the PANI layer, further enhancing the detection efficiency. Developed GC/PANI-NWA/Pb2+-ISE showed outstanding potentiometric performance, including a low Pb2+ detection limit (2.5 x 10(-8) M), a short response time (about 1 s), high stability in N-2 (or O-2) and no light sensitivity. Further, the water layer between the solid-contact layer and the ISM was largely eliminated when three-dimensional PANI-NWA were applied as the solid contact layer, thus enhancing the stability of the ISE. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Stable Pb(II) ion-selective electrodes with a low detection limit using silver nanoparticles/polyaniline as the solid contact
    Xianghua Zeng
    Wenwen Jiang
    Geoffrey I. N. Waterhouse
    Xiaohui Jiang
    Zhiming Zhang
    Liangmin Yu
    Microchimica Acta, 2021, 188
  • [22] Solid-contact polymeric membrane ion-selective electrodes based on electrodeposited NiCo2S4 nanosheet arrays br
    Li, Yanhong
    Li, Jinghui
    Qin, Wei
    TALANTA, 2023, 251
  • [23] Solid-contact polymeric membrane ion-selective electrodes using a covalent organic framework@reduced graphene oxide composite as ion-to-electron transducer
    Zhang, Wenting
    Li, Jinghui
    Qin, Wei
    TALANTA, 2023, 258
  • [24] Influence of hydrophobization of the polyazulene ion-to-electron transducer on the potential stability of calcium-selective solid-contact electrodes
    He, Ning
    Hoefler, Lajos
    Latonen, Rose-Marie
    Lindfors, Tom
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 918 - 925
  • [25] Micro Solid-Contact Ion-Selective Electrode Using a Carbon Nanotube Tower as Ion-to-Electron Transducer and Conductive Substrate
    Guo, Xuefei
    Meyung, Timothy
    Yun, Yeoheung
    Shanov, Vesselin N.
    Halsall, H. Brian
    Heineman, William R.
    ELECTROANALYSIS, 2012, 24 (11) : 2045 - 2048
  • [26] A Solid-contact Pb2+-selective Electrode with Carbon Nanotubes by Electrodeposition as Ion-to-electron Transducer
    Song, Yuehai
    Ma, Lijie
    ELECTROCHEMISTRY, 2015, 83 (06) : 402 - 405
  • [27] TEMPO-Functionalized Carbon Nanotubes for Solid-Contact Ion-Selective Electrodes with Largely Improved Potential Reproducibility and Stability
    Kozma, Jozsef
    Tapp, Soma
    Gyurcsanyi, Robert E.
    ANALYTICAL CHEMISTRY, 2022, 94 (23) : 8249 - 8257
  • [28] Influence of inner transducer properties on EMF response and stability of solid-contact anion-selective membrane electrodes based on metalloporphyrin ionophores
    Gorski, Lukasz
    Matusevich, Alexey
    Pietrzak, Mariusz
    Wang, Lin
    Meyerhoff, Mark E.
    Malinowska, Elzbieta
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (01) : 157 - 164
  • [29] Influence of inner transducer properties on EMF response and stability of solid-contact anion-selective membrane electrodes based on metalloporphyrin ionophores
    Łukasz Górski
    Alexey Matusevich
    Mariusz Pietrzak
    Lin Wang
    Mark E. Meyerhoff
    Elżbieta Malinowska
    Journal of Solid State Electrochemistry, 2009, 13 : 157 - 164
  • [30] Thiol-functionalized reduced graphene oxide as self-assembled ion-to-electron transducer for durable solid-contact ion-selective electrodes
    Liu, Yueling
    Liu, Yunzhong
    Meng, Zhen
    Qin, Yu
    Jiang, Dechen
    Xi, Kai
    Wang, Ping
    TALANTA, 2020, 208