摘要
In a recent short-term physiological study, we demonstrated a new continuous positive airway pressure (CPAP) system (neonatal helmet-CPAP) chat could be a feasible device for managing preterm infants needing continuous distending pressure with better tolerability than nasal-CPAP. However, its application for a long-term period has never been reported in neonates. Here, we describe the use of neonatal helmet-CPAP in a neonate with persistent pulmonary hypertension of the newborn. Twenty minutes after neonatal helmet-CPAP placement, the baseline post-ductal tcSaO(2) (66%) and alveolar-arterial gradient O-2 improved from 66% and 648 mmHg to 100% and 465 mmHg, respectively. The neonatal helmet-CPAP was applied for 48 hours and was well-tolerated by the patient without complications. Long-term use of neonatal helmet-CPAP appears feasible and well-tolerated. Comparative trials are needed.. (Minerva Stomatol 2009;75:750-3)
引用
收藏
页码:750 / 753
页数:4
相关论文
共 14 条
[1]   New treatment of acute hypoxemic respiratory failure: Noninvasive pressure support ventilation delivered by helmet - A pilot controlled trial [J].
Antonelli, M ;
Conti, G ;
Pelosi, P ;
Gregoretti, C ;
Pennisi, MA ;
Costa, R ;
Severgnini, P ;
Chiaranda, M ;
Proietti, R .
CRITICAL CARE MEDICINE, 2002, 30 (03) :602-608
[2]  
Bellani G, 2008, MINERVA ANESTESIOL, V74, P651
[3]   Continuous positive airway pressure with modified helmet for treatment of hypoxemic acute respiratory failure in infants and a preschool population: A feasibility study [J].
Codazzi, Daniela ;
Nacoti, Mirco ;
Passoni, Maurizio ;
Bonanomi, Ezio ;
Sperti, Lidia Rota ;
Fumagalli, Roberto .
PEDIATRIC CRITICAL CARE MEDICINE, 2006, 7 (05) :455-460
[4]   Non-invasive respiratory support of preterm neonates with respiratory distress: Continuous positive airway pressure and nasal intermittent positive pressure ventilation [J].
Davis, Peter G. ;
Morley, Colin J. ;
Owen, Louise S. .
SEMINARS IN FETAL & NEONATAL MEDICINE, 2009, 14 (01) :14-20
[5]   Development and initial validation of the EDIN scale, a new tool for assessing prolonged pain in preterm infants [J].
Debillon, T ;
Zupan, V ;
Ravault, N ;
Magny, JF ;
Dehan, M .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2001, 85 (01) :F36-F40
[6]  
DEPAOLI AG, DEVICES PRESSURE SOU
[7]   A pilot study of inhaled nitric oxide in preterm infants treated with nasal continuous positive airway pressure for respiratory distress syndrome [J].
Lindwall, R ;
Blennow, M ;
Svensson, M ;
Jonsson, B ;
Berggren-Boström, E ;
Flanby, M ;
Lönnqvist, PA ;
Frostell, C ;
Norman, M .
INTENSIVE CARE MEDICINE, 2005, 31 (07) :959-964
[8]   Delivery characteristics of a combined nitric oxide nasal continuous positive airway pressure system [J].
Lindwall, R ;
Frostell, CG ;
Lönnqvist, PA .
PAEDIATRIC ANAESTHESIA, 2002, 12 (06) :530-536
[9]   Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study [J].
Patroniti, N ;
Foti, G ;
Manfio, A ;
Coppo, A ;
Bellani, G ;
Pesenti, A .
INTENSIVE CARE MEDICINE, 2003, 29 (10) :1680-1687
[10]   CONTINUOUS POSITIVE AIRWAY PRESSURE MODULATES EFFECT OF INHALED NITRIC-OXIDE ON THE VENTILATION-PERFUSION DISTRIBUTIONS IN CANINE LUNG INJURY [J].
PUTENSEN, C ;
RASANEN, J ;
LOPEZ, FA ;
DOWNS, JB .
CHEST, 1994, 106 (05) :1563-1569