Changes in End-Organ Function in Patients With Prolonged Continuous-Flow Left Ventricular Assist Device Support

被引:35
|
作者
Yoshioka, Daisuke
Takayama, Hiroo
Colombo, Paolo C.
Yuzefpolskaya, Melana
Garan, Arthur R.
Topkara, Veli K.
Han, Jiho
Kurlansky, Paul
Naka, Yoshifumi
Takeda, Koji
机构
[1] Columbia Univ, Med Ctr, Div Cardiothorac Surg, New York, NY USA
[2] Columbia Univ, Med Ctr, Div Cardiol, New York, NY USA
来源
ANNALS OF THORACIC SURGERY | 2017年 / 103卷 / 03期
关键词
CENTRAL VENOUS-PRESSURE; ACUTE KIDNEY INJURY; HEART-FAILURE; RENAL-FUNCTION; HOSPITAL READMISSIONS; CIRCULATORY SUPPORT; IMPLANTATION; PULSATILE; DISEASE; SYSTEM;
D O I
10.1016/j.athoracsur.2016.12.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Few studies have evaluated the long-term effects of continuous blood flow with reduced pulsatility on end-organ function. Methods. Between May 2004 and December 2015, 469 patients underwent continuous-flow left ventricular assist device (LVAD) implantation at our center. Our study included 59 (13%) patients who were supported with an LVAD for a minimum of 3 years. We evaluated postoperative renal function and hepatic function at 1 and 6 months, and 1, 2, and 3 years after implantation in those 59 patients. Results. The patients' mean age was 63 +/- 13 years, 81% were male, 53% had an ischemic cause of heart failure, and 68% underwent LVAD implantation as destination therapy. All laboratory determinations showed significant improvements at 1 month after the procedure. Hepatic values remained in a normal range for up to 3 years, although renal function improvement was predominantly transient. One month after implantation, the mean estimated glomerular filtration rate (eGFR) was improved from 58.2 +/- 27.9 to 77.7 +/- 33.5 mL/min/1.73 m(2). However, 46 (78%) patients showed a gradual decline in eGFR to only 1.7% above the preoperative value after 3 years (p = 0.67 vs baseline). The risk factors for impaired renal function after long-term support were age 60 years or older, ischemic cause, and late right heart failure. Conclusions. Continuous-flow LVAD improves renal and hepatic functions in patients with advanced heart failure. However, in most, the initial improvement in renal function is largely transient and returns to baseline after a prolonged support period. (C) 2017 by The Society of Thoracic Surgeons
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [41] Coronary arterial function is not impaired in patients following continuous-flow left ventricular assist device implantation
    Johnson, Elizabeth
    Diakos, Nikos
    Selzman, Craig
    Reid, Bruce
    Stehlik, Josef
    Kfoury, Abdallah
    Saidi, Abdulfatah
    Wever-Pinzon, Omar
    Verma, Divya R.
    Yen, Chi-Gang
    Li, Dean
    Drakos, Stavros
    Symons, J. David
    FASEB JOURNAL, 2013, 27
  • [42] Effects of the HeartMate II Continuous-Flow Left Ventricular Assist Device on RV Function
    Lee, S.
    Kamdar, F.
    Madlon-Kay, R.
    John, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S277 - S277
  • [43] Effects of Continuous-Flow Left Ventricular Assist Device Therapy on Peripheral Vascular Function
    Kaya, Ersin
    Kocabas, Umut
    Simsek, Evrim
    Nalbantgil, Sanem
    Kahraman, Umit
    Engin, Cagatay
    Yagdi, Tahir
    Ozbaran, Mustafa
    Akilli, Azem
    ASAIO JOURNAL, 2022, 68 (02) : 214 - 219
  • [44] β-Blockers Use During Support with Continuous-Flow Left Ventricular Assist Device in Patients with and without Right Ventricular Dysfunction
    Yin, M.
    Pekarek, A.
    Wittersheim, K.
    Cole, R. T.
    Gupta, D.
    Laskar, R.
    Smith, A.
    Vega, D.
    Morris, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S171 - S171
  • [45] MYOCARDIAL AND END-ORGAN RESPONSE AFTER LONG-TERM MECHANICAL UNLOADING WITH CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICE: AXIAL-VERSUS CENTRIFUGAL-FLOW
    Al-Sarie, Mohammad
    Rauf, Asad
    Wever-Pinzon, James
    Catino, Anna
    Stehlik, Josef
    Kfoury, Abdallah
    McKellar, Stephen H.
    Pinzon, Omar Wever
    Kelkhoff, Aaron
    Alharethi, Rami
    Reid, Bruce
    Fang, James
    Selzman, Craig
    Drakos, Stavros
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1387 - 1387
  • [46] Myocardial and End-Organ Response after Long-Term Mechanical Unloading with Continuous-Flow Left Ventricular Assist Device: Axial- Versus Centrifugal-Flow
    Al-Sarie, M.
    Rauf, A.
    Wever-Pinzon, J.
    Catino, A.
    Stehlik, J.
    Kfouri, A.
    McKellar, S. H.
    Wever-Pinzon, O.
    Kelkhoff, A.
    Alharethi, R.
    Reid, B.
    Fang, J.
    Selzman, C.
    Drakos, S. G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S330 - S330
  • [47] Right Ventricular Function in Patients With Left Ventricular Assist Device Support by Pulsatile Polvad MEV and Continuous-Flow Pumps Heartware and Heartmate II
    Nadziakiewicz, P.
    Borkowski, J.
    Szygula-Jurkiewicz, B.
    Niklewski, T.
    Pacholewicz, J.
    Zakliczynski, M.
    Hrapkowic, T.
    Zennbala, M.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (05) : 1786 - 1790
  • [48] Alloantibody Desensitization Therapy in Bridge-to-Transplant Patients on Continuous-Flow Left Ventricular Assist Device Support
    Bejar, D.
    Colombo, P. C.
    Jennings, D.
    Garan, A. R.
    Yuzefpolskaya, M.
    Takeda, K.
    Takayama, H.
    Castagna, F.
    Maurer, M.
    Zorn, E.
    Latif, F.
    Restaino, S.
    Farr, M. A.
    Naka, Y.
    Mancini, D. M.
    Topkara, V. K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S282 - S283
  • [49] Gender differences in the risk of stroke during support with continuous-flow left ventricular assist device
    Morris, Alanna A.
    Pekarek, Ann
    Wittersheim, Kris
    Cole, Robert T.
    Gupta, Divya
    Duc Nguyen
    Laskar, S. Raja
    Butler, Javed
    Smith, Andrew
    Vega, J. David
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12): : 1570 - 1577
  • [50] Spontaneous Oscillatory Left Ventricular-Aortic Uncoupling Under Continuous-Flow Left Ventricular Assist Device Support
    Jain, Pankaj
    Meredith, Thomas
    Adji, Audrey
    Schnegg, Bruno
    Hayward, Christopher S.
    CIRCULATION-HEART FAILURE, 2021, 14 (02) : E007658