Experimental Investigation of Reinforced Concrete T-Beams Strengthened in Shear with Externally Bonded CFRP Sheets

被引:36
作者
Foster, Robert M. [1 ]
Brindley, Monika [2 ]
Lees, Janet M. [3 ]
Ibell, Tim J. [2 ]
Morley, Chris T. [4 ]
Darby, Antony P. [2 ]
Evernden, Mark C. [2 ]
机构
[1] Univ Cambridge, Dept Architecture, Cambridge CB2 1PX, England
[2] Univ Bath, Dept Architecture & Civil Engn, Bath BA2 7AY, Avon, England
[3] Univ Cambridge, Dept Engn, Civil Engn, Cambridge CB2 1PX, England
[4] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
基金
英国工程与自然科学研究理事会;
关键词
Reinforced concrete T-beam; Shear strengthening; Externally bonded carbon fiber-reinforced polymer fabric; Size effect; POLYMER SHEETS; BEHAVIOR; STIRRUPS; STRIPS; SIZE;
D O I
10.1061/(ASCE)CC.1943-5614.0000743
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental investigation was undertaken into the effectiveness of unanchored and anchored externally bonded (EB) U-wrapped carbon fiber-reinforced polymer (CFRP) shear strengthening for reinforced concrete T-beams at a range of realistic sizes. The T-beam sizes, geometry, and reinforcement were chosen to reflect existing slab-on-beam structures with low levels of transverse steel shear reinforcement. Geometrically similar reinforced concrete T-beams were tested across three sizes ranging from 360 to 720mm in depth and with different amounts of EB CFRP shear reinforcement. The beams were subjected to three-point bending with a span-to-depth ratio of 3.5. All the beams failed in diagonal shear. The experimental results indicate significant variability in the capacity of unstrengthened control beams, and a number of these control beams showed greater shear capacity than their EB CFRP-strengthened counterparts. Greater thicknesses of CFRP reinforcement did not lead to increased shear capacity compared with less thicknesses of unanchored or anchored EB CFRP, but anchored EB CFRP did lead to moderate increases in shear capacity compared with both control and unanchored EB CFRP-strengthened beams. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 28 条
[1]  
AASHTO, 2008, BRIDG GAP REST REB N
[2]  
[Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
[3]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[4]  
[Anonymous], D7522D7522M15 ASTM
[5]  
[Anonymous], P AUSTR 5 BRIDG C AU
[6]   Fiber-reinforced polymer composites for construction-state-of-the-art review [J].
Bakis, CE ;
Bank, LC ;
Brown, VL ;
Cosenza, E ;
Davalos, JF ;
Lesko, JJ ;
Machida, A ;
Rizkalla, SH ;
Triantafillou, TC .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (02) :73-87
[7]  
Barrera A. C., 2006, P 2 FIB INT C
[8]  
Bousselham A, 2006, ACI STRUCT J, V103, P339
[9]  
BSI, 2004, BS EN 1992-1-1:2004 Eurocode 2: Design of concrete structures: General rules and rules for buildings
[10]  
BSI, 2005, BS 4449: 2005