Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational Fluoroscopy

被引:58
|
作者
Reinacher, P. C. [1 ]
Krueger, M. T. [2 ]
Coenen, V. A. [1 ]
Shah, M. [2 ]
Roelz, R. [2 ]
Jenkner, C. [4 ]
Egger, K. [3 ]
机构
[1] Freiburg Univ, Med Ctr, Dept Stereotact & Funct Neurosurg, Freiburg, Germany
[2] Freiburg Univ, Med Ctr, Dept Neurosurg, Freiburg, Germany
[3] Freiburg Univ, Med Ctr, Dept Neuroradiol, Freiburg, Germany
[4] Freiburg Univ, Clin Trial Unit, Med Ctr, Freiburg, Germany
关键词
RUBRO-THALAMIC TRACT; SUBTHALAMIC NUCLEUS; ASSESSING AGREEMENT; TREMOR; DBS;
D O I
10.3174/ajnr.A5153
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: New deep brain stimulation leads with electrode contacts that are split along their circumference allow steering of the electrical field in a predefined direction. However, imaging-assisted directional stimulation requires detailed knowledge of the exact orientation of the electrode array. The purpose of this study was to evaluate whether this information can be obtained by rotational 3D fluoroscopy. MATERIALS AND METHODS: Two directional leads were inserted into a 3D-printed plaster skull filled with gelatin. The torsion of the lead tip versus the lead at the burr-hole level was investigated. Then, 3 blinded raters evaluated 12 3D fluoroscopies with random lead orientations. They determined the lead orientation considering the x-ray marker only and considering the overlap of the gaps between the contact segments. Intraclass correlation coefficients and an extended version of the Bland-Altman plot were used to determine interrater reliability and agreement of the measurements of the different raters. RESULTS: Electrode torsion of up to 35 degrees could be demonstrated. Evaluation of the lead rotation considering the x-ray marker only revealed limits of agreement of 9.37 degrees and an intraclass correlation coefficient of 0.9975. In addition, taking into account the lines resulting from overlapping of the gaps between the electrode segments, the limits of agreement to the mean were +/- 2.44 degrees and an intraclass correlation coefficient of 0.9998. CONCLUSIONS: In directional deep brain stimulation systems, rotational 3D fluoroscopy combined with the described evaluation method allows for determining the exact orientation of the leads, enabling the full potential of imaging-assisted personalized programming.
引用
收藏
页码:1111 / 1116
页数:6
相关论文
共 50 条
  • [1] Regarding "Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational Fluoroscopy"
    Treuer, H.
    Hellerbach, A.
    Borggrefe, J.
    Visser-Vandewalle, V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) : E105 - E105
  • [2] Regarding "Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational Fluoroscopy" REPLY
    Reinacher, P. C.
    Krueger, M. T.
    Coenen, V. A.
    Shah, M.
    Roelz, R.
    Jenkner, C.
    Egger, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (12) : E106 - E108
  • [3] Determining the rotational orientation of directional deep brain stimulation electrodes using magnetoencephalography
    Yalaz, Mevlut
    Deuschl, Gunther
    Sohail Noor, M.
    Butz, Markus
    Schnitzler, Alfons
    Helmers, Ann-Kristin
    Hoeft, Michael
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (05)
  • [4] Determining the Rotational Orientation of Directional Deep Brain Stimulation Leads Employing Flat-Panel Computed Tomography
    Hunsche, Stefan
    Neudorfer, Clemens
    El Majdoub, Faycal
    Maarouf, Mohammad
    Sauner, Dieter
    OPERATIVE NEUROSURGERY, 2019, 16 (04) : 465 - 470
  • [5] 3D X-ray based visualization of directional deep brain stimulation lead orientation
    Egger, Karl
    Rau, Alexander
    Urbach, Horst
    Reisert, Marco
    Reinacher, Peter C.
    JOURNAL OF NEURORADIOLOGY, 2022, 49 (03) : 293 - 297
  • [6] Viability and Accuracy of Visual Estimation in Determining Directional Deep Brain Stimulation Lead Orientation
    Brandt, G. A.
    vander Linden, C.
    Schedlich-Teufer, C.
    Visser-Vandevalle, V.
    Barbe, M. T.
    Dembek, T. A.
    MOVEMENT DISORDERS, 2024, 39 : S551 - S551
  • [7] Potential for reduction of radiation dose in the assessment of the lead orientation in directional deep brain stimulation electrodes
    Schuermann, Till
    Stein, Thomas
    Urbach, Horst
    Sajonz, Bastian E. A.
    Bamberg, Fabian
    Coenen, Volker A.
    Rau, Alexander
    Reinacher, Peter C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [8] Intraoperative 3D fluoroscopy accurately predicts final electrode position in deep brain stimulation surgery
    Neto-Fernandes, Patricia
    Chamadoira, Clara
    Silva, Carolina
    Pereira, Leila
    Vaz, Rui
    Rito, Manuel
    Ferreira-Pinto, Manuel J.
    ACTA NEUROCHIRURGICA, 2024, 166 (01)
  • [9] Comparison of methodologies for modeling directional deep brain stimulation electrodes
    Frankemolle-Gilbert, Anneke M.
    Howell, Bryan
    Bower, Kelsey L.
    Veltink, Peter H.
    Heida, Tjitske
    McIntyre, Cameron C.
    PLOS ONE, 2021, 16 (12):
  • [10] Temporal Stability of Lead Orientation in Directional Deep Brain Stimulation
    Dembek, Till A.
    Asendorf, Adrian L.
    Wirths, Jochen
    Barbe, Michael T.
    Visser-Vandewalle, Veerle
    Treuer, Harald
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2021, 99 (02) : 167 - 170