Optimization of image collection for cellular electron microscopy

被引:28
作者
Mooney, Paul [1 ]
机构
[1] Gatan Inc, Pleasanton, CA 94588 USA
来源
CELLULAR ELECTRON MICROSCOPY | 2007年 / 79卷
关键词
D O I
10.1016/S0091-679X(06)79027-6
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Image collection is a key aspect of all kinds of electron microscopy (EM), including microscopy of the cell. Optimal use of existing detectors and continuing improvements to detector technology are crucial to further advancements in cellular EM. In order to pursue optimization of use and development of detectors, it is critical to understand central performance limitations and trade-offs. Spectral signal-to-noise ratio (SSNR) is presented as a means to quantify image quality and detective quantum efficiency (DQE) as a means to quantify detector performance relative to the generation of good SSNR. These quantities are used to describe a number of areas of cellular EM, and various improvements both to technique and to detector technology are described. Further work is needed to understand the SSNR implications of postacquisition processing in order to better understand the correct trade-offs to make in instrumentation development. Expected developments could help to bridge the resolution gap between cellular and molecular structural biology.
引用
收藏
页码:661 / 719
页数:59
相关论文
共 72 条
[1]  
AGARD DA, 2004, SEARL SCHOLARS PROGR
[2]  
AIKENS RS, 1989, METHOD CELL BIOL, V29, P291
[3]  
BAILEY B, 2004, MICROSC MICROANAL S2, V10, P1204
[4]   Assessing the capabilities of a 4kx4k CCD camera for electron cryo-microscopy at 300kV [J].
Booth, Christopher R. ;
Jakana, Joanita ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2006, 156 (03) :556-563
[5]   A 9 Å single particle reconstruction from CCD captured images on a 200 kV electron cryomicroscope [J].
Booth, CR ;
Jiang, W ;
Baker, ML ;
Zhou, ZH ;
Ludtke, SJ ;
Chiu, W .
JOURNAL OF STRUCTURAL BIOLOGY, 2004, 147 (02) :116-127
[6]   Automated most-probable loss tomography of thick selectively stained biological specimens with quantitative measurement of resolution improvement [J].
Bouwer, JC ;
Mackey, MR ;
Lawrence, A ;
Deerinck, TJ ;
Jones, YZ ;
Terada, M ;
Martone, ME ;
Peltier, S ;
Ellisman, MH .
JOURNAL OF STRUCTURAL BIOLOGY, 2004, 148 (03) :297-306
[7]   APPLICATIONS OF A SLOW-SCAN CCD CAMERA IN PROTEIN ELECTRON CRYSTALLOGRAPHY [J].
BRINK, J ;
CHIU, W .
JOURNAL OF STRUCTURAL BIOLOGY, 1994, 113 (01) :23-34
[8]   Endosomal compartments serve multiple hippocampal dendritic spines from a widespread rather than a local store of recycling membrane [J].
Cooney, JR ;
Hurlburt, JL ;
Selig, DK ;
Harris, KM ;
Fiala, JC .
JOURNAL OF NEUROSCIENCE, 2002, 22 (06) :2215-2224
[9]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[10]   PERFORMANCE OF ELECTRON IMAGE CONVERTERS WITH YAG SINGLE-CRYSTAL SCREEN AND CCD SENSOR [J].
DABERKOW, I ;
HERRMANN, KH ;
LIU, LB ;
RAU, WD .
ULTRAMICROSCOPY, 1991, 38 (3-4) :215-223