Test-retest intra-rater reliability of vaginal measurement of pelvic floor muscle strength using Myomed 932

被引:18
|
作者
Sigurdardottir, Thorgerdur [1 ]
Steingrimsdottir, Thora [2 ,3 ]
Arnason, Arni [1 ]
Bo, Kari [4 ]
机构
[1] Univ Iceland, Dept Physiotherapy, IS-101 Reykjavik, Iceland
[2] Univ Iceland, Dept Obstet & Gynecol, IS-101 Reykjavik, Iceland
[3] Reykjavik Primary Hlth Care Serv, Ctr Antenatal Hlth, Reykjavik, Iceland
[4] Norwegian Sch Sport Sci, Dept Sports Med, Oslo, Norway
关键词
Pelvic floor muscle strength; vaginal pressure measurements; intra-tester reliability; test-retest; Myomed; STRESS URINARY-INCONTINENCE; PRESSURE MEASUREMENTS; EXERCISE; WOMEN; CONTRACTION; ULTRASOUND; POSITIONS;
D O I
10.1080/00016340903093567
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives. To investigate test-retest intra-rater reliability of measurements of pelvic floor muscle (PFM) strength using Myomed 932 (R) (Enraf-Nonius, Delft, the Netherlands). Design. Test-retest intra-rater reliability test with a 2-7 day interval. Setting. Physiotherapy outpatient clinic in association with the Department of Physiotherapy, University of Iceland. Population. Twenty healthy female volunteers in Reykjavik metropolitan area, Iceland, with a mean age of 43.8 (SD 9.8) years, mean body mass index (BMI) 26.2 (SD 5.3), and mean parity 2.1 children (SD 1.0). Main outcome measures. PFM strength during two attempts of maximal voluntary contraction (MVC) measured as vaginal squeeze pressure in hectoPascals (hPa). Results. Mean MVC was 34.45 hPa (95% CI: 26.07-42.83) on Day 1 and 34.05 hPa (95% CI: 26.66-41.44) on Day 2. The measurements ranged from 5-74 hPa interindividually on Day 1 and 5-62 hPa on Day 2. Intraclass Correlation Coefficient (ICC) was 0.97; p<0.001 and coefficient of variation (CV%) was 11.09%. There was no significant difference between the first and second tests (p = 0.74). Conclusion. This test-retest intra-rater reliability study for Myomed 932 showed a very good reliability using ICC. The CV%, however, indicated some degree of intra-individual variation. We suggest that this device can be used both in practice and clinical trials for assessing female PFM strength.
引用
收藏
页码:939 / 943
页数:5
相关论文
共 27 条
  • [21] Assessing the robustness of muscle strength and physical performance measures in women older than 40 years: a test-retest reliability study
    Silva, Sebastiao Henrique Assis
    Orsatti, Fabio L.
    de Lima, Mariana L.
    de Freitas, Augusto C. Q.
    Carneiro, Marcelo A. S.
    Assumpcao, Claudio de Oliveira
    Souza, Markus Vinicius C.
    MENOPAUSE-THE JOURNAL OF THE MENOPAUSE SOCIETY, 2024, 31 (01): : 33 - 38
  • [22] Test-Retest Reliability, Validity, and Minimal Detectable Change of the Measurement of Lower Limb Muscular Strength with Handheld Dynamometry in Patients Undergoing Hemodialysis
    Perez-Dominguez, Borja
    Lopez-Brull, Aida
    Plaza-Carrasco, Maria
    Casana-Granell, Jose
    Garcia-Testal, Alicia
    Benitez-Martinez, Josep
    INTERNATIONAL JOURNAL OF NEPHROLOGY, 2022, 2022
  • [23] Test-Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
    Tuominen, Juho
    Leppanen, Mari
    Jarske, Heidi
    Pasanen, Kati
    Vasankari, Tommi
    Parkkari, Jari
    METHODS AND PROTOCOLS, 2023, 6 (02)
  • [24] Test-retest reliability of a load cell setup, Ito, and timed loaded standing tests for measuring muscle strength and endurance in older adults with and without hyperkyphosis
    Keshavarzi, Fatemeh
    Azadinia, Fatemeh
    Talebian, Saeed
    Rasouli, Omid
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2022, 58
  • [25] Test–retest and intra-observer repeatability of two-, three- and four-dimensional perineal ultrasound of pelvic floor muscle anatomy and function
    Ingeborg Hoff Brækken
    Memona Majida
    Marie Ellstrøm-Engh
    Hans Peter Dietz
    Wolfgang Umek
    Kari Bø
    International Urogynecology Journal, 2008, 19 : 227 - 235
  • [26] Novel approach for noninvasive pelvic floor muscle strength measurement using extracorporeal surface perineal pressure measurement and machine learning modeling
    Hwang, Ui-jae
    Ahn, Sun-hee
    Lee, Hyeon-ju
    Jeon, Yurin
    Jeon, Myung Jae
    DIGITAL HEALTH, 2025, 11
  • [27] Fully Automatic MRI-Based Hippocampus Volumetry Using FSL-FIRST: Intra-Scanner Test-Retest Stability, Inter-Field Strength Variability, and Performance as Enrichment Biomarker for Clinical Trials Using Prodromal Target Populations at Risk for Alzheimer's Disease
    Cavedo, Enrica
    Suppa, Per
    Lange, Catharina
    Opfer, Roland
    Lista, Simone
    Galluzzi, Samantha
    Schwarz, Adam J.
    Spies, Lothar
    Buchert, Ralph
    Hampel, Harald
    JOURNAL OF ALZHEIMERS DISEASE, 2017, 60 (01) : 151 - 164