Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization

被引:31
作者
Li, Xin [1 ]
Pan, Jullie W. [2 ,3 ]
Avdievich, Nikolai, I [4 ]
Hetherington, Hoby P. [2 ]
Rispoli, Joseph, V [1 ,5 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, 206 S Martin Jischke Dr, W Lafayette, IN 47907 USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
[3] Univ Pittsburgh, Dept Neurol, Pittsburgh, PA 15260 USA
[4] Max Planck Inst Biol Cybernet, High Field MR Ctr, Tubingen, Germany
[5] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
基金
美国国家卫生研究院;
关键词
co‐ simulation; EM simulation; parallel transmission; RF shimming; transformer decoupling; ultrahigh‐ field MRI;
D O I
10.1002/mrm.28672
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose With increased interest in parallel transmission in ultrahigh-field MRI, methods are needed to correctly calculate the S-parameters and complex field maps of the parallel transmission coil. We present S-parameters paired with spatial field optimization to fully simulate a double-row 16-element transceiver array for brain MRI at 7 T. Methods We implemented a closed-form equation of the coil S-parameters and overall spatial B1+ field. We minimized a cost function, consisting of coil S-parameters and the B1+ homogeneity in brain tissue, by optimizing transceiver components, including matching, decoupling circuits, and lumped capacitors. With this, we are able to compare the in silico results determined with and without B1+ homogeneity weighting. Using the known voltage range from the host console, we reconstructed the B1+ maps of the array and performed RF shimming with four realistic head models. Results As performed with B1+ homogeneity weighting, the optimized coil circuit components were highly consistent over the four heads, producing well-tuned, matched, and decoupled coils. The mean peak forward powers and B1+ statistics for the head models are consistent with in vivo human results (N = 8). There are systematic differences in the transceiver components as optimized with or without B1+ homogeneity weighting, resulting in an improvement of 28.4 +/- 7.5% in B1+ homogeneity with a small 1.9 +/- 1.5% decline in power efficiency. Conclusion This co-simulation methodology accurately simulates the transceiver, predicting consistent S-parameters, component values, and B1+ field. The RF shimming of the calculated field maps match the in vivo performance.
引用
收藏
页码:3463 / 3478
页数:16
相关论文
共 45 条
[41]   Whole-Body Imaging at 7T: Preliminary Results [J].
Vaughan, T. Thomas ;
Snyder, Carl J. ;
DelaBarre, Lance J. ;
Bolan, Patrick J. ;
Tian, Jinfeng ;
Bolinger, Lizann ;
Adriany, Gregor ;
Andersen, Peter ;
Strupp, John ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) :244-248
[42]   An eight-channel, nonoverlapping phased array coil with capacitive decoupling for parallel MRI at 3 T [J].
Von Morze, Cornelius ;
Tropp, James ;
Banerjee, Suchandrima ;
Xu, Duan ;
Karpodinis, Kostas ;
Carvajal, Lucas ;
Hess, Christopher P. ;
Mukherjee, Pratik ;
Majumdar, Sharmila ;
Vigneron, Daniel B. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2007, 31B (01) :37-43
[43]   Self-decoupled radiofrequency coils for magnetic resonance imaging [J].
Yan, Xinqiang ;
Gore, John C. ;
Grissom, William A. .
NATURE COMMUNICATIONS, 2018, 9
[44]  
Zelinka I, 2016, STUD COMPUT INTELL, V626, P3, DOI 10.1007/978-3-319-28161-2_1
[45]  
Zhang R, 2009, P INT SOC MAGN RESON, P3040