Sensitive and cost effective disposable composite electrode based on graphite, nano-smectite and multiwall carbon nanotubes for the simultaneous trace level detection of ascorbic acid and acetylsalicylic acid in pharmaceuticals

被引:26
作者
Bayraktepe, Dilek Eskikoy [1 ]
Yazan, Zehra [1 ]
Onal, Muserref [1 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06560 Ankara, Turkey
关键词
Pencil graphite electrode; Nano-smectite; Multiwall carbon nanotubes; Voltammetry ascorbic acid; Acetyl salicylic acid; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL SENSOR; BEHAVIOR; ASPIRIN; SAMPLES; ACETAMINOPHEN; PARACETAMOL; DOPAMINE; TABLETS;
D O I
10.1016/j.talanta.2019.05.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we used nano-smectite (SMT) and multiwall carbon nanotube (MWCNT) as a recognition surface over the disposable pencil graphite electrode for the low-level detection of ascorbic acid (AA) and acetyl salicylic acid (ACA). Firstly, nano-semectit was obtained by the purification of natural bentonite clay. XRD patterns and Scanning electron microscopy (SEM) were employed to ensure the purity of the bentonite samples. Pencil graphite rodes were immersed into suspensions of SMT, MWCNT or the both.The surface morphology of the sensor was investigated by cyclic voltammery (CV), electrochemical impedance spectroscopy (EIS) and SEM techniques. The effect of pH, percentage composition of modifiers, immobilization time, accumulation time and accumulation potential was optimized for reaching the best electroanalytical response for AA and ACA. The sensor developed proved to give good recovery, notable electro-catalytic activity and appropriately distant signals for the simultaneous determination of the analytes. Common contaminates, uric acid, L-cysteine, dopamine, glucose, Na+, Cl- and citric acid were investigated for their interference effects. Uric acid, citric acid and dopamine were found to interfere to some extent. The electrode exhibited wide working ranges and a fairly satisfactory detection limit of 0.096 and 0.241 mu M for AA and ACA, respectively. The electrode system proved to be practical for the analysis of pharmaceutical tablets and the recovery results are very satisfactory.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 43 条
[1]   An electrochemical label-free and sensitive thrombin aptasensor based on graphene oxide modified pencil graphite electrode [J].
Ahour, F. ;
Ahsani, M. K. .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :764-769
[2]  
Akay Cemal, 1999, Drug Metabolism and Drug Interactions, V15, P197
[3]   Electrocatalytic oxidation of salicylic acid at a carbon paste electrode impregnated with cerium-doped zirconium oxide nanoparticles as a new sensing approach for salicylic acid determination [J].
Alizadeh, Taher ;
Nayeri, Sahar .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (07) :2039-2048
[4]   Gold nanoparticle-modified graphite pencil electrode for the high-sensitivity detection of hydrazine [J].
Aziz, Md Abdul ;
Kawde, Abdel-Nasser .
TALANTA, 2013, 115 :214-221
[5]   Sensitive and selective voltammetric determination of anti-cancer agent shikonin on sepiolite clay/TiO2 nanoparticle/MWCNTs composite carbon paste sensor and investigation of its electro-oxidation mechanism [J].
Bayraktepe, Dilek Eskikoy ;
Yazan, Zehra ;
Polat, Kamran .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 :38-45
[6]  
Bergaya F, 2006, DEV CLAY SCI, V1, P1, DOI 10.1016/S1572-4352(05)01001-9
[7]   An improved amperometric L-lactate biosensor based on covalent immobilization of microbial lactate oxidase onto carboxylated multiwalled carbon nanotubes/copper nanoparticles/polyaniline modified pencil graphite electrode [J].
Dagar, Kusum ;
Pundir, C. S. .
ENZYME AND MICROBIAL TECHNOLOGY, 2017, 96 :177-186
[8]   The spectrophotometric multicomponent analysis of a ternary mixture of ascorbic acid, acetylsalicylic acid and paracetamol by the double divisor-ratio spectra derivative and ratio spectra-zero crossing methods [J].
Dinç, E .
TALANTA, 1999, 48 (05) :1145-1157
[9]   Comparative study of the continuous wavelet transform, derivative and partial least squares methods applied to the overlapping spectra for the simultaneous quantitative resolution of ascorbic acid and acetylsalicylic acid in effervescent tablets [J].
Dinç, E ;
Ozdemir, A ;
Baleanu, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) :569-575
[10]  
Dinc E., J PHARM BIOMED ANAL, V37, P569