Advantages of using a mercury coated, micro-wire, electrode in adsorptive cathodic stripping voltammetry

被引:27
作者
Gun, Jenny
Salaun, Pascal
van den Berg, Constant M. G.
机构
[1] Univ Liverpool, Dept Earth & Ocean Sci, Liverpool L69 3GP, Merseyside, England
[2] Hebrew Univ Jerusalem, Casali Inst Appl Chem, Environm Chem Lab, IL-91904 Jerusalem, Israel
基金
英国自然环境研究理事会;
关键词
cathodic stripping voltammetry; microelectrode; iron; seawater;
D O I
10.1016/j.aca.2006.04.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mercury coated, gold, micro-wire electrode is used here for the determination of iron in seawater by catalytic cathodic stripping voltammetry (CSV) with a limit of detection of 0.1 nM Fe at a 60 s adsorption time. It was found that the electrode surface is stable for extended periods of analyses (at least five days) and that it is reactivated by briefly (2 s) applying a negative potential prior to each scan. Advantages of this electrode over mercury drop electrodes are that metallic mercury use is eliminated and that it can be readily used for flow analysis. This is demonstrated here by the determination of iron in seawater by continuous flow analysis. It is likely that this method can be extended to other elements. Experiments using bismuth coated, carbon fibre, electrodes showed that the bismuth catalyses the oxidation of the important oxidants bromate and hydrogen peroxide, which makes it impossible to use bismuth based electrodes for catalytic CSV involving these oxidants. For this reason mercury coated electrodes retain a major advantage for catalytic voltammetric analyses. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 92
页数:7
相关论文
共 26 条
[1]  
Aldrich AP, 1998, ELECTROANAL, V10, P369, DOI 10.1002/(SICI)1521-4109(199805)10:6<369::AID-ELAN369>3.0.CO
[2]  
2-W
[3]   Gold and silver micro-wire electrodes for trace analysis of metals [J].
Billon, G ;
van den Berg, CMG .
ELECTROANALYSIS, 2004, 16 (19) :1583-1591
[4]   Application of a bismuth film electrode to the voltammetric determination of trace iron using a Fe(III)-TEA-BrO3- catalytic system [J].
Bobrowski, A ;
Nowak, K ;
Zarebski, J .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (07) :1691-1697
[5]   A flow cell for on-line monitoring of metals in natural waters by voltammetry with a mercury drop electrode [J].
Colombo, C ;
van den Berg, CMG ;
Daniel, A .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :101-111
[6]   THE APPLICATION OF AC POLAROGRAPHY TO THE DETERMINATION OF SURFACE-ACTIVE SUBSTANCES IN SEA-WATER [J].
COSOVIC, B ;
VOJVODIC, V .
LIMNOLOGY AND OCEANOGRAPHY, 1982, 27 (02) :361-368
[7]   Sequential flow analysis coupled with ACSV for on-line monitoring of cobalt in the marine environment [J].
Daniel, A ;
Baker, AR ;
van den Berg, CMG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (06) :703-710
[8]   DETERMINATION OF COMPLEXATION OF IRON(III) WITH NATURAL ORGANIC COMPLEXING LIGANDS IN SEAWATER USING CATHODIC STRIPPING VOLTAMMETRY [J].
GLEDHILL, M ;
VAN DEN BERG, CMG .
MARINE CHEMISTRY, 1994, 47 (01) :41-54
[9]  
HEYROVSKY J, 1966, PRINCIPLES POLAROGRA, P581
[10]   AUTOMATED-DETERMINATION OF TOTAL ARSENIC IN SEA-WATER BY FLOW CONSTANT-CURRENT STRIPPING ANALYSIS WITH GOLD FIBER ELECTRODES [J].
HUA, C ;
JAGNER, D ;
RENMAN, L .
ANALYTICA CHIMICA ACTA, 1987, 201 :263-268