Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts

被引:24
作者
Senila, Marin [1 ]
Cadar, Oana [1 ]
Senila, Lacrimioara [1 ]
Boeringer, Sarah [2 ]
Seaudeau-Pirouley, Karine [3 ]
Ruiu, Andrea [4 ]
Lacroix-Desmazes, Patrick [4 ]
机构
[1] Natl Inst Res & Dev Optoelect Bucharest, Res Inst Analyt Instrumentat, Cluj Napoca 400293, Romania
[2] Fraunhofer Inst Chem Technol ICT, Dept Environm Engn, Grp React & Separat Tech, D-76327 Pfinztal, Germany
[3] Innovat Fluides Supercrit IFS, Batiment INEED,BP16109, F-26300 Alixan, France
[4] Univ Montpellier, CNRS, ENSCM, Inst Charles Gerhardt Montpellier ICGM, F-34095 Montpellier, France
基金
欧盟地平线“2020”;
关键词
palladium; platinum; ICP-OES; catalysts; method validation; microwave digestion; PLATINUM-GROUP METALS; ONLINE SEPARATION; PALLADIUM; PRECONCENTRATION; VALIDATION; RECOVERY; RHODIUM; DIGESTION; TRACES; FOODS;
D O I
10.3390/ma13225136
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Palladium (Pd) and platinum (Pt) are extensively used as catalysts in the petrochemical and automotive industries, and due to high demand for them on the market, their recycling from spent supported catalysts is clearly needed. To assess the content of Pd and Pt in catalysts in order to establish their commercial value or to evaluate the recovery efficiency of technologies used for recycling, reliable analytical methods for determination of these elements are required. Spectrometric methods, such as inductively coupled plasma optical emission spectrometry (ICP-OES) and graphite furnace atomic absorption spectrometry (GFAAS) are powerful tools that can be employed for the determination of Pd and Pt in various sample matrices. However, these methods allow only the injection of liquid samples. In this regard, the digestion of solid sample by microwave-assisted acid extraction procedures at high pressures and temperatures is often used. In this study, a microwave acid digestion method was optimized for the extraction of Pd and Pt from spent catalysts, using a four-step program, at a maximum 200 degrees C. The resulting solutions were analyzed using ICP-OES, at two different wavelengths for each metal (Pd at 340.458 and 363.470 nm, and Pt at 265.945 and 214.423 nm, respectively) and using GFAAS (Pd at 247.64 nm, Pt at 265.94 nm). Five types of spent catalyst were analyzed and the standard deviations of repeatability for five parallel samples were less than predicted relative standard deviations (PRSD%) calculated using Horvitz's equation for all the analyzed samples.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
[41]   Determination of Lead in Plastic Food Packaging by Graphite Furnace Atomic Absorption Spectrometry [J].
Silvaa, Tiago Varao ;
Miranda, Kelber ;
Ferreira, Edilene Cristina ;
Santos, Mirian Cristina ;
Gomes Neto, Jose Anchieta ;
Barbosa, Fernando, Jr. .
ATOMIC SPECTROSCOPY, 2015, 36 (04) :182-186
[42]   Preconcentration of Vanadium(Ⅴ) on Crosslinked Chitosan and Determination by Graphite Furnace Atomic Absorption Spectrometry [J].
Wu Wei Qian Shahua k Xiao Mei Huang Ganquan Chen Hao College of Resource and Environmental Science Wuhan University Wuhan Hubei China Department of Chemistry Huazhong Agricultural University Wuhan .
WuhanUniversityJournalofNaturalSciences, 2002, (02) :222-226
[43]   Determination of cadmium in rice by microwave digestion and graphite furnace atomic absorption spectrometry [J].
Amakawa, E ;
Ogiwara, T ;
Ohhashi, N ;
Kamata, K ;
Suzuki, S .
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2000, 41 (01) :66-69
[44]   Determination of tin and lead in sediment slurries by graphite furnace atomic absorption spectrometry [J].
Lopes, Aline Soriano ;
Zezzi Arruda, Marco Aurelio .
MICROCHIMICA ACTA, 2009, 164 (3-4) :445-451
[45]   Optimization of the operating conditions in inductively coupled plasma optical emission spectrometry [J].
Velitchkova, N. S. ;
Velichkov, S. V. ;
Karadjov, M. G. ;
Daskalova, N. N. .
BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 :152-159
[46]   ADVANCES IN INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY FOR ENVIRONMENTAL ANALYSIS [J].
Butcher, David J. .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2010, 38 (06) :458-469
[47]   Determination of metallic elements in carbon nanotubes by inductively coupled plasma-optical emission spectrometry [J].
Ishikuro, M ;
Sato, Y ;
Tohji, K ;
Wagatsuma, K .
BUNSEKI KAGAKU, 2006, 55 (02) :117-120
[48]   Simultaneous Determination of Thorium and Uranium in Mineral Fertilizers by Inductively Coupled Plasma Optical Emission Spectrometry [J].
Souza, Sidnei O. ;
Avila, Dayara V. L. ;
Monteiro, Adnivia S. C. ;
Garcia, Carlos Alexandre B. ;
Alves, Jose P. H. ;
Maranhao, Tatiane A. ;
Araujo, Rennan G. O. .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (04) :799-806
[49]   Trace Analysis of Au in Carbonaceous Gold Ores by Inductively Coupled Plasma Optical Emission Spectrometry and Mass Spectrometry [J].
Suyama, Ikumi ;
Mendoza, Diego M. ;
Kaneta, Takashi ;
Sasaki, Keiko .
MATERIALS TRANSACTIONS, 2024, 65 (06) :644-651
[50]   Determination of the Mineral Compositions of in Six Beans by Microwave Digestion with Inductively Coupled Plasma Atomic Emission Spectrometry [J].
Yan, Qinghua ;
Yang, Li ;
Chen, Shuyang ;
Liu, Xi ;
Ma, Xiaoqin .
JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (03) :767-770