Performance Parameters of Inductively Coupled Plasma Optical Emission Spectrometry and Graphite Furnace Atomic Absorption Spectrometry Techniques for Pd and Pt Determination in Automotive Catalysts

被引:24
作者
Senila, Marin [1 ]
Cadar, Oana [1 ]
Senila, Lacrimioara [1 ]
Boeringer, Sarah [2 ]
Seaudeau-Pirouley, Karine [3 ]
Ruiu, Andrea [4 ]
Lacroix-Desmazes, Patrick [4 ]
机构
[1] Natl Inst Res & Dev Optoelect Bucharest, Res Inst Analyt Instrumentat, Cluj Napoca 400293, Romania
[2] Fraunhofer Inst Chem Technol ICT, Dept Environm Engn, Grp React & Separat Tech, D-76327 Pfinztal, Germany
[3] Innovat Fluides Supercrit IFS, Batiment INEED,BP16109, F-26300 Alixan, France
[4] Univ Montpellier, CNRS, ENSCM, Inst Charles Gerhardt Montpellier ICGM, F-34095 Montpellier, France
基金
欧盟地平线“2020”;
关键词
palladium; platinum; ICP-OES; catalysts; method validation; microwave digestion; PLATINUM-GROUP METALS; ONLINE SEPARATION; PALLADIUM; PRECONCENTRATION; VALIDATION; RECOVERY; RHODIUM; DIGESTION; TRACES; FOODS;
D O I
10.3390/ma13225136
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Palladium (Pd) and platinum (Pt) are extensively used as catalysts in the petrochemical and automotive industries, and due to high demand for them on the market, their recycling from spent supported catalysts is clearly needed. To assess the content of Pd and Pt in catalysts in order to establish their commercial value or to evaluate the recovery efficiency of technologies used for recycling, reliable analytical methods for determination of these elements are required. Spectrometric methods, such as inductively coupled plasma optical emission spectrometry (ICP-OES) and graphite furnace atomic absorption spectrometry (GFAAS) are powerful tools that can be employed for the determination of Pd and Pt in various sample matrices. However, these methods allow only the injection of liquid samples. In this regard, the digestion of solid sample by microwave-assisted acid extraction procedures at high pressures and temperatures is often used. In this study, a microwave acid digestion method was optimized for the extraction of Pd and Pt from spent catalysts, using a four-step program, at a maximum 200 degrees C. The resulting solutions were analyzed using ICP-OES, at two different wavelengths for each metal (Pd at 340.458 and 363.470 nm, and Pt at 265.945 and 214.423 nm, respectively) and using GFAAS (Pd at 247.64 nm, Pt at 265.94 nm). Five types of spent catalyst were analyzed and the standard deviations of repeatability for five parallel samples were less than predicted relative standard deviations (PRSD%) calculated using Horvitz's equation for all the analyzed samples.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
[21]   Determination of antimony in wine by hydride generation graphite furnace atomic absorption spectrometry [J].
Anne-Marie Wifladt ;
Grethe Wibetoe ;
W. Lund .
Fresenius' Journal of Analytical Chemistry, 1997, 357 :92-96
[22]   Determination of elemental impurities in poly(vinyl chloride) by inductively coupled plasma optical emission spectrometry [J].
Pereira, Leticia S. F. ;
Pedrotti, Matheus F. ;
Miceli, Tatiane M. ;
Pereira, Juliana S. F. ;
Flores, Erico M. M. .
TALANTA, 2016, 152 :371-377
[23]   Preconcentration of platinum group metals on modified silicagel and their determination by inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry in airborne particulates [J].
Vlasánkova, R ;
Otruba, V ;
Bendl, J ;
Fisera, M ;
Kanicky, V .
TALANTA, 1999, 48 (04) :839-846
[24]   Determination of gold in geological materials by carbon slurry sampling graphite furnace atomic absorption spectrometry [J].
Dobrowolski, Ryszard ;
Kurylo, Michal ;
Otto, Magdalena ;
Mroz, Agnieszka .
TALANTA, 2012, 99 :750-757
[25]   Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Zambrzycka-Szelewa, Elzbieta ;
Lulewicz, Marta ;
Godlewska-Zylkiewicz, Beata .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 :81-87
[26]   Determination of inorganic elements in geopropolis samples by inductively coupled plasma optical emission spectrometry [J].
Siqueira, Jean Sanger ;
Mescouto, Cleide Samara Tavares ;
Lemos, Michelle de Souza ;
Junior, Joao Batista Pereira ;
Venturieri, Giorgio C. ;
Dantas Filho, Heronides Adonias ;
Dantas, Kelly das Gracas Fernandes .
JOURNAL OF APICULTURAL RESEARCH, 2022, 61 (03) :400-407
[27]   Direct analysis of deodorants for determination of metals by inductively coupled plasma optical emission spectrometry [J].
Oliveira Correia da Costa, Wiviane Kassia ;
da Silva, Caroline Santos ;
Dagnone Figueiredo, Jose Fernando ;
Nobrega, Joaquim Araujo ;
Silveira Paim, Ana Paula .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 155 :247-252
[28]   Determination of Pd, Rh, Pt, Au in road dust by electrothermal vaporization inductively coupled plasma mass spectrometry with slurry sampling [J].
Hsu, Wan-Hsuan ;
Jiang, Shiuh-Jen ;
Sahayam, A. C. .
ANALYTICA CHIMICA ACTA, 2013, 794 :15-19
[29]   Determination of impurities in highly pure platinum by inductively coupled plasma-atomic emission spectrometry [J].
Zhang, XH ;
Li, HF ;
Yang, YF .
TALANTA, 1995, 42 (12) :1959-1963
[30]   Determination of Matrix Element Sodium in the Sodium Metavanadate by Inductively Coupled Plasma Atomic Emission Spectrometry [J].
Cheng Yong .
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON CHEMICAL, MATERIAL AND FOOD ENGINEERING, 2015, 22 :899-901