A generic approach to post-column refocusing in liquid chromatography

被引:28
作者
De Vos, Jelle [1 ]
Desmet, Gert [1 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
Detection limits; Solid-phase extraction; Heart-cut LC; Solvent switch; Modulation; MASS-SPECTROMETRY; TEMPERATURE; SYSTEM; OPTIMIZATION; ANTIBIOTICS; INJECTION; PRESSURE; COLUMNS;
D O I
10.1016/j.chroma.2014.07.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To increase detection sensitivity in liquid chromatography, a generic post-column refocusing strategy has been developed to enrich (target) analytes prior to detection. In this strategy, after separation on the analytical column, the analytes are led to a trap column preferably containing a stationary phase with strong retentive properties (e.g. silica C-30). They are then eluted using a strong solvent in a backward-elution mode. A first key element of the proposed strategy is that the trapping time should be at least equal to the time the front of the remobilization solvent needs to cover the entire length of the trap column, divided by the ratio of the flow rates used for trapping and remobilization. This condition is independent of the retention properties of the analytes in the trapping and remobilization solvent, Another essential element is the addition of a third solvent (isopropanol in the present case) to the remobilization solvent to overcome viscous-fingering effects caused by the viscosity difference between the trap and the remobilization solvents. The potential of the proposed post-column refocusing strategy is demonstrated for an isocratic separation of KI (t(0) marker), an antibiotic (sulfamethazine), and acetophenone as a case study. Using optimized remobilization conditions a maximum signal-enhancement factor of 8 was achieved. Higher enhancement factors using a remobilization solvent with slightly higher elution strength were prohibited by disturbances of the UV background signal. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 28 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P244, DOI 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO
[2]  
2-0
[3]   Influence of pressure and temperature on the physico-chemical properties of mobile phase mixtures commonly used in high-performance liquid chromatography [J].
Billen, Jeroen ;
Broeckhoven, Ken ;
Liekens, Anuschka ;
Choikhet, Konstantin ;
Rozing, Gerard ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1210 (01) :30-44
[4]   Visualization of viscous fingering in chromatographic columns [J].
Broyles, BS ;
Shalliker', RA ;
Cherrak, DE ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) :173-187
[5]   Visualising the onset of viscous fingering in chromatography columns [J].
Catchpoole, Heather J. ;
Shalliker, R. Andrew ;
Dennis, Gary R. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) :137-145
[6]   A COMPARATIVE-STUDY OF LARGE VOLUME INJECTION TECHNIQUES FOR MICROBORE COLUMNS IN HPLC [J].
CLAESSENS, HA ;
KUYKEN, MAJ .
CHROMATOGRAPHIA, 1987, 23 (05) :331-336
[7]   Visualization and quantification of the onset and the extent of viscous fingering in micro-pillar array columns [J].
De Malsche, Wim ;
De Beeck, Jeff Op ;
Gardeniers, Han ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) :5511-5517
[8]   Viscous fingering of miscible slices [J].
De Wit, A ;
Bertho, Y ;
Martin, M .
PHYSICS OF FLUIDS, 2005, 17 (05) :1-9
[9]  
Dolan JW, 2014, LC GC EUR, V27, P304
[10]   Exploring the Possibilities of Cryogenic Cooling in Liquid Chromatography for Biological Applications: A Proof of Principle [J].
Eghbali, Hamed ;
Sandra, Koen ;
Tienpont, Bart ;
Eeltink, Sebastiaan ;
Sandra, Pat ;
Desmet, Gert .
ANALYTICAL CHEMISTRY, 2012, 84 (04) :2031-2037