Bipolar ablation for deep intra-myocardial circuits: human ex vivo development and in vivo experience

被引:33
作者
Gizurarson, Sigfus [1 ]
Spears, Danna [1 ]
Sivagangabalan, Gopal [1 ]
Farid, Talha [2 ]
Ha, Andrew C. T. [1 ]
Masse, Stephane [1 ]
Kusha, Marjan [2 ]
Chauhan, Vijay S. [1 ]
Nair, Krishnakumar [1 ]
Harris, Louise [1 ]
Downar, Eugene [1 ]
Nanthakumar, Kumaraswamy [1 ,2 ]
机构
[1] Toronto Gen Hosp, Div Cardiol, Toronto, ON M5G 2C4, Canada
[2] Toronto Gen Hosp, Hull Family Cardiac Fibrillat Management Lab, Toronto, ON M5G 2C4, Canada
来源
EUROPACE | 2014年 / 16卷 / 11期
关键词
Bipolar ablation; Ventricular tachycardia; Langendorff perfusion; VENTRICULAR-TACHYCARDIA; RADIOFREQUENCY ABLATION; ATRIAL-FIBRILLATION; CATHETER ABLATION; UNIPOLAR ABLATION; EFFICACY; SAFETY; TERM;
D O I
10.1093/europace/euu001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Current conventional ablation strategies for ventricular tachycardia (VT) aim to interrupt reentrant circuits by creating ablation lesions. However, the critical components of reentrant VT circuits may be located at deep intramural sites. We hypothesized that bipolar ablations would create deeper lesions than unipolar ablation in human hearts. Methods and results Ablation was performed on nine explanted human hearts at the time of transplantation. Following explant, the hearts were perfused by using a Langendorff perfusion setup. For bipolar ablation, the endocardial catheter was connected to the generator as the active electrode and the epicardial catheter as the return electrode. Unipolar ablation was performed at 50 W with irrigation of 25 mL/min, with temperature limit of 50 degrees C. Bipolar ablation was performed with the same settings. Subsequently, in a patient with an incessant septal VT, catheters were positioned on the septum from both the ventricles and radiofrequency was delivered with 40 W. In the explanted hearts, there were a total of nine unipolar ablations and four bipolar ablations. The lesion depth was greater with bipolar ablation, 14.8 vs. 6.1 mm(P < 0.01), but the width was not different (9.8 vs. 7.8 mm). All bipolar lesions achieved transmurality in contrast to the unipolar ablations. In the patient with a septal focus, bipolar ablation resulted in termination of VT with no inducible VTs. Conclusion By using a bipolar ablation technique, we have demonstrated the creation of significantly deeper lesions without increasing the lesion width, compared with standard ablation. Further clinical trials are warranted to detail the risks of this technique.
引用
收藏
页码:1684 / 1688
页数:5
相关论文
共 15 条
[1]   Long-Term Efficacy of Single Procedure Remote Magnetic Catheter Navigation for Ablation of Ischemic Ventricular Tachycardia: A Retrospective Study [J].
Dinov, Borislav ;
Schoenbauer, Robert ;
Wojdyla-Hordynska, Agnieska ;
Braunschweig, Frieder ;
Richter, Sergio ;
Altmann, David ;
Sommer, Philipp ;
Gaspar, Thomas ;
Bollmann, Andreas ;
Wetzel, Ulrike ;
Rolf, Sascha ;
Piorkowski, Christopher ;
Hindricks, Gerhard ;
Arya, Arash .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (05) :499-505
[2]   Radiofrequency catheter ablation: Different cooled and noncooled electrode systems induce specific lesion geometries and adverse effect profiles [J].
Dorwarth, U ;
Fiek, M ;
Remp, T ;
Reithmann, C ;
Dugas, M ;
Steinbeck, G ;
Hoffmann, E .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07) :1438-1445
[3]   Isolated septal substrate for ventricular tachycardia in nonischemic dilated cardiomyopathy: Incidence, characterization, and implications [J].
Haqqani, Haris M. ;
Tschabrunn, Cory M. ;
Tzou, Wendy S. ;
Dixit, Sanjay ;
Cooper, Joshua M. ;
Riley, Michael P. ;
Lin, David ;
Hutchinson, Mathew D. ;
Garcia, Fermin C. ;
Bala, Rupa ;
Verdino, Ralph J. ;
Callans, David J. ;
Gerstenfeld, Edward P. ;
Zado, Erica S. ;
Marchlinski, Francis E. .
HEART RHYTHM, 2011, 8 (08) :1169-1176
[4]   Catheter ablation of multiple ventricular tachycardias after myocardial infarction guided by combined contact and noncontact mapping [J].
Klemm, Hanno U. ;
Ventura, Rodolfo ;
Steven, Daniel ;
Johnsen, Christin ;
Rostock, Thomas ;
Lutomsky, Boris ;
Risius, Tim ;
Meinertz, Thomas ;
Willems, Stephan .
CIRCULATION, 2007, 115 (21) :2697-2704
[5]   Bipolar irrigated radiofrequency ablation: A therapeutic option for refractory intramural atrial and ventricular tachycardia circuits [J].
Koruth, Jacob S. ;
Dukkipati, Srinivas ;
Miller, Marc A. ;
Neuzil, Petr ;
d'Avila, Andre ;
Reddy, Vivek Y. .
HEART RHYTHM, 2012, 9 (12) :1932-1941
[6]   Ablation of atrial fibrillation with cryoballoon or duty-cycled radiofrequency pulmonary vein ablation catheter: a randomized controlled study comparing the clinical outcome and safety; the AF-COR study [J].
Malmborg, Helena ;
Lonnerholm, Stefan ;
Blomstrom, Per ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2013, 15 (11) :1567-1573
[7]   Epicardial Ablation With Irrigated Electrodes - Effect of Bipolar vs. Unipolar Ablation on Lesion Formation [J].
Nagashima, Koichi ;
Watanabe, Ichiro ;
Okumura, Yasuo ;
Sonoda, Kazumasa ;
Kofune, Masayoshi ;
Mano, Hiroaki ;
Ohkubo, Kimie ;
Nakai, Toshiko ;
Kunimoto, Satoshi ;
Kasamaki, Yuji ;
Hirayama, Atsushi .
CIRCULATION JOURNAL, 2012, 76 (02) :322-327
[8]  
Ramana Ravi K, 2007, J Invasive Cardiol, V19, pE142
[9]   Transcoronary ethanol ventricular tachycardia ablation in the modern electrophysiology era [J].
Sacher, Frederic ;
Sobieszczyk, Piotr ;
Tedrow, Usha ;
Eisenhauer, Andrew C. ;
Fied, MichaeL E. ;
Setwyn, Andrew ;
Raymond, Jean-Marc ;
Koplan, Bruce ;
Epstein, Laurence M. ;
Stevenson, WiLham G. .
HEART RHYTHM, 2008, 5 (01) :62-68
[10]   Large radiofrequency ablation lesions can be created with a retractable infusion-needle catheter [J].
Sapp, John L. ;
Cooper, Joshua M. ;
Zei, Paul ;
Stevenson, William G. .