Transplant renal artery stenosis - Evaluation of diagnosis with magnetic resonance angiography compared with color duplex sonography and arteriography

被引:36
|
作者
Loubeyre, P [1 ]
Cahen, R [1 ]
Grozel, F [1 ]
Trolliet, P [1 ]
PouteilNoble, C [1 ]
Labeeuw, M [1 ]
Minh, VT [1 ]
机构
[1] CTR HOSP LYON SUD,DEPT NEPHROL,F-69495 PIERRE BENITE,FRANCE
关键词
D O I
10.1097/00007890-199608270-00004
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The goal of this study was to assess the value of a three-dimensional phase contrast magnetic resonance angiography (3D PC MRA) for diagnosing transplant renal artery stenosis (TRAS). Twelve consecutive patients clinically suspected of having TRAS were prospectively enrolled during a period of 18 months. Delays hom transplantation varied from 3 months to 4 years (mean: 18.3 months). Patients first had color Doppler sonography, then MRA-and, on the following day, intraarterial digital subtraction angiography (IADSA), The site of the maximum peak systolic velocity was noted when doing the report of each color Doppler sonogram, On MRA images, any signal cutoff or any vascular narrowing of more than 50% of the diameter of the vessel was considered to be a significant stenosis. Eight patients were considered to have TRAS on MRA, but only two stenoses were noted oil IADSA. The six false-positive results of MRA (due to major intravoxel phase dispersion) were observed when elevated peak systolic velocities were noted on doppler sonograms (mean: 214 cm/sec). These elevated peak systolic velocities were noted in the proximal part of the renal artery when there was a tortuous vessel or a sharp angle between the renal artery and the parent vessel. It: is our opinion that 3D PC MRA is of limited value for the diagnosis of renal transplant artery stenosis because of a high number of false-positive results.
引用
收藏
页码:446 / 450
页数:5
相关论文
共 50 条
  • [31] Respective value of renal scintigraphy, intrarenal Doppler sonography and magnetic resonance angiography for the detection of renal artery stenosis
    Soulez, GP
    Oliva, VL
    Nicolet, V
    Froment, D
    Courteau, M
    Therasse, E
    RADIOLOGY, 1999, 213P : 271 - 271
  • [32] Overestimation of the degree of stenosis in the intracranial internal carotid artery determined by magnetic resonance angiography compared to conventional arteriography
    Durán-Ferreras, E
    Schoeck, AP
    Barest, GD
    Viereck, JC
    Babikian, VL
    Kase, CS
    REVISTA DE NEUROLOGIA, 2003, 37 (08) : 730 - 732
  • [33] Evaluation of severe transplant renal artery stenosis with Doppler sonography
    Li, JC
    Ji, ZG
    Cai, S
    Jiang, YX
    Dai, Q
    Zhang, JX
    JOURNAL OF CLINICAL ULTRASOUND, 2005, 33 (06) : 261 - 269
  • [34] RENAL ARTERY STENOSIS: THE COMPARISON OF THE DOPPLER USG, CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY AND SELECTIVE RENAL ARTERIOGRAPHY
    Turgutalp, Kenan
    Kiykim, Ahmet
    Helvaci, Ilter
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 356 - 356
  • [35] Multiple renal arteries and non-contrast magnetic resonance angiography in transplant renal artery stenosis
    Mendoza, Jair Munoz
    Melcher, Marc L.
    Daniel, Bruce
    Tan, Jane C.
    CLINICAL KIDNEY JOURNAL, 2012, 5 (03): : 272 - 275
  • [36] DETECTION OF INTERNAL CAROTID-ARTERY STENOSIS - COMPARISON OF MR ANGIOGRAPHY, COLOR DOPPLER SONOGRAPHY, AND ARTERIOGRAPHY
    POLAK, JF
    BAJAKIAN, RL
    OLEARY, DH
    ANDERSON, MR
    DONALDSON, MC
    JOLESZ, FA
    RADIOLOGY, 1992, 182 (01) : 35 - 40
  • [37] Misleading Diagnosis of Renal Artery Stenosis by Magnetic Resonance Angiography in a Patient with Primary Aldosteronism
    Ippersiel, V.
    Rosiere, A.
    Michel, L.
    Donckier, J.
    ACTA CHIRURGICA BELGICA, 2012, 112 (04) : 302 - 306
  • [38] The Performance of Noncontrast Magnetic Resonance Angiography in Detecting Renal Artery Stenosis as Compared With Contrast Enhanced Magnetic Resonance Angiography Using Conventional Angiography as a Reference
    Liang, Keng-Wei
    Chen, Jhih-Wei
    Huang, Hsin-Hui
    Su, Chun-Hung
    Tyan, Yeu-Sheng
    Tsao, Teng-Fu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 619 - 627
  • [39] Accuracy of Transcranial Doppler Ultrasound Compared with Magnetic Resonance Angiography in the Diagnosis of Intracranial Artery Stenosis
    Jaiswal, Sandip Kumar
    Yan Fu-ling
    Gu, Lihua
    Lico, Renardo
    Fu Changyong
    Paula, Angela
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2019, 10 (03) : 400 - 404
  • [40] Utility of color doppler ultrasound in the evaluation of renal artery stenosis in comparison with contrast-enhanced magnetic resonance angiography
    Abuagla, Elnasri M.
    Pei, Tan Sook