Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings

被引:49
|
作者
MacNaughton, Piers [1 ]
Pegues, James [2 ]
Satish, Usha [3 ]
Santanam, Suresh [4 ]
Spengler, John [1 ]
Allen, Joseph [1 ]
机构
[1] Harvard Univ, TH Chan Sch Publ Hlth, Dept Environm Hlth, Landmark 409 West,401 Pk Dr, Boston, MA 02115 USA
[2] United Technol Climate Controls & Secur, Syracuse, NY 13221 USA
[3] SUNY Upstate Med Sch, Psychiat & Behav Sci, Syracuse, NY 13210 USA
[4] Syracuse Univ, Biomed & Chem Engn Dept, Ind Assessment Ctr, Syracuse, NY 13210 USA
关键词
green buildings; energy and environmental costs; health; productivity; AIR SUPPLY RATE; CLIMATE-CHANGE; SYNDROME SBS; RISK; QUALITY;
D O I
10.3390/ijerph121114709
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoptionEconomic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.
引用
收藏
页码:14709 / 14722
页数:14
相关论文
共 50 条
  • [1] Hybrid ventilation of office buildings
    Heikkinen, Jorma
    Heinonen, Jarkko
    Vuolle, Mika
    Laine, Tuomas
    Liljeström, Kimmo
    VTT Tiedotteita - Valtion Teknillinen Tutkimuskeskus, 2002, (2179): : 3 - 113
  • [2] Energy and economic analysis of environmental upgrading of existing office buildings
    Dinh Manh Nguyen
    Ding, Grace
    Runeson, Goran
    CONSTRUCTION ECONOMICS AND BUILDING, 2020, 20 (04): : 82 - 102
  • [3] COMPARISON OF HEALTH-PROBLEMS RELATED TO WORK AND ENVIRONMENTAL MEASUREMENTS IN 2 OFFICE BUILDINGS WITH DIFFERENT VENTILATION SYSTEMS
    ROBERTSON, AS
    BURGE, PS
    HEDGE, A
    SIMS, J
    GILL, FS
    FINNEGAN, M
    PICKERING, CAC
    DALTON, G
    BRITISH MEDICAL JOURNAL, 1985, 291 (6492): : 373 - 376
  • [4] VENTILATION MEASUREMENTS IN LARGE OFFICE BUILDINGS
    PERSILY, AK
    GROT, RA
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1984, 26 (05): : 55 - 55
  • [5] Survey of ventilation rates in office buildings
    Persily, Andrew K.
    Gorfain, Josh
    Brunner, Greg
    BUILDING RESEARCH AND INFORMATION, 2006, 34 (05): : 459 - 466
  • [6] Economic and environmental analysis of energy renovation packages for European office buildings
    Gustafsson, Marcus
    Dipasquale, Chiara
    Poppi, Stefano
    Bellini, Alessandro
    Fedrizzi, Roberto
    Bales, Chris
    Ochs, Fabian
    Sie, Marion
    Holmberg, Sture
    ENERGY AND BUILDINGS, 2017, 148 : 155 - 165
  • [7] BUILDING SICKNESS A COMPARISON OF WORK RELATED HEALTH-PROBLEMS AND ENVIRONMENTAL MEASUREMENTS IN 2 OFFICE BUILDINGS WITH DIFFERENT VENTILATION SYSTEMS
    ROBERTSON, AS
    BURGE, PS
    FINNEGAN, M
    PICKERING, CAC
    HEDGE, A
    SIMMS, J
    GILL, F
    DALTON, G
    THORAX, 1985, 40 (03) : 211 - 211
  • [8] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [9] Night ventilation control strategies in office buildings
    Wang, Zhaojun
    Yi, Lingli
    Gao, Fusheng
    SOLAR ENERGY, 2009, 83 (10) : 1902 - 1913
  • [10] THE VENTILATION AND HEATING EQUIPMENT IN OFFICE AND INDUSTRIAL BUILDINGS
    不详
    KALTE UND KLIMATECHNIK, 1982, 35 (05): : 188 - 188