Computed tomography lung iodine contrast mapping by image registration and subtraction

被引:5
作者
Goatman, Keith [1 ]
Plakas, Costas [1 ]
Schuijf, Joanne [2 ]
Beveridge, Erin [1 ]
Prokop, Mathias [3 ]
机构
[1] Toshiba Med Visualizat Syst, Edinburgh, Midlothian, Scotland
[2] Toshiba Med Syst Europe, Zoetermeer, Netherlands
[3] UMC, Dept Radiol, Nijmegen, Netherlands
来源
MEDICAL IMAGING 2014: IMAGE PROCESSING | 2014年 / 9034卷
关键词
Medical imaging; Registration; Subtraction; Lung; CT; NONRIGID REGISTRATION; PULMONARY-EMBOLISM; DIAGNOSIS;
D O I
10.1117/12.2043551
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aqui lion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57 mm (range 1.43-4 34 mm), and following registration the mean error was 0.54 mm (range 0.44-0.64 mm) The mean surface error distance was 1.89 mm before registration and 0.47 mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction iodine mapping.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Enhancement pattern mapping technique for improving contrast-to-noise ratios and detectability of hepatobiliary tumors on multiphase computed tomography
    Park, Peter C.
    Choi, Gye W.
    Zaid, Mohamed M.
    Elganainy, Dalia
    Smani, Danyal A.
    Tomich, John
    Samaniego, Ray
    Ma, Jingfei
    Tamm, Eric P.
    Beddar, Sam
    Koay, Eugene J.
    MEDICAL PHYSICS, 2020, 47 (01) : 64 - 74
  • [42] Evaluation of Computed Tomography to Ultrasound 2D Image Registration for Atrial Fibrillation Treatment
    Sandoval, Zulma L.
    Dillenseger, Jean-Louis
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 245 - 248
  • [43] Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography
    Mai, Hai Yen
    Lee, Du-Hyeong
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [44] An unsupervised image registration method employing chest computed tomography images and deep neural networks
    Ho, Thao Thi
    Kim, Woo Jin
    Lee, Chang Hyun
    Jin, Gong Yong
    Chae, Kum Ju
    Choi, Sanghun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 154
  • [45] Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography
    Shirai, Ryota
    Kunii, Takuya
    Yoneyama, Akio
    Ooizumi, Takahito
    Maruyama, Hiroko
    Lwin, Thet-Thet
    Hyodo, Kazuyuki
    Takeda, Tohoru
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 795 - 800
  • [46] A Review of Ultrasound and Computed Tomography Registration Approaches
    Mazaheri, Samaneh
    Sulaiman, Puteri Suhaiza Binti
    Wirza, Rahmita
    Dimon, Mohd Zamrin
    Khalid, Fatimah
    Tayebi, Rohollah Moosavi
    2014 INTERNATIONAL CONFERENCE ON COMPUTER ASSISTED SYSTEM IN HEALTH (CASH 2014), 2014, : 6 - 11
  • [47] Deep learning image reconstruction for quality assessment of iodine concentration in computed tomography: A phantom study
    Jeon, Pil-Hyun
    Lee, Chang-Lae
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (02) : 409 - 422
  • [48] Anatomy-aware computed tomography-to-ultrasound spine registration
    Azampour, Mohammad Farid
    Tirindelli, Maria
    Lameski, Jane
    Gafencu, Miruna
    Tagliabue, Eleonora
    Fatemizadeh, Emad
    Hacihaliloglu, Ilker
    Navab, Nassir
    MEDICAL PHYSICS, 2024, 51 (03) : 2044 - 2056
  • [49] Evaluating anemia on non-contrast thoracic computed tomography
    Abbasi, Bita
    Hosseini, Maliheh Seyed
    Ghalibaf, AmirAli Moodi
    Akhavan, Reza
    Emadzadeh, Maryam
    Bolvardi, Ehsan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [50] The first patient treatment of computed tomography ventilation functional image-guided radiotherapy for lung cancer
    Yamamoto, Tokihiro
    Kabus, Sven
    Bal, Matthieu
    Keall, Paul
    Benedict, Stanley
    Daly, Megan
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (02) : 227 - 231