Computed tomography lung iodine contrast mapping by image registration and subtraction

被引:5
作者
Goatman, Keith [1 ]
Plakas, Costas [1 ]
Schuijf, Joanne [2 ]
Beveridge, Erin [1 ]
Prokop, Mathias [3 ]
机构
[1] Toshiba Med Visualizat Syst, Edinburgh, Midlothian, Scotland
[2] Toshiba Med Syst Europe, Zoetermeer, Netherlands
[3] UMC, Dept Radiol, Nijmegen, Netherlands
来源
MEDICAL IMAGING 2014: IMAGE PROCESSING | 2014年 / 9034卷
关键词
Medical imaging; Registration; Subtraction; Lung; CT; NONRIGID REGISTRATION; PULMONARY-EMBOLISM; DIAGNOSIS;
D O I
10.1117/12.2043551
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aqui lion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57 mm (range 1.43-4 34 mm), and following registration the mean error was 0.54 mm (range 0.44-0.64 mm) The mean surface error distance was 1.89 mm before registration and 0.47 mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction iodine mapping.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Deformable image registration for temporal subtraction of chest radiographs
    Li, Min
    Castillo, Edward
    Luo, Hong-Yan
    Zheng, Xiao-Lin
    Castillo, Richard
    Meshkov, Dmitriy
    Guerrero, Thomas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (04) : 513 - 522
  • [32] Weight-Adjusted Contrast Administration in the Computed Tomography Evaluation of Pulmonary Embolism
    Ratnakanthan, Prasanna J.
    Kavnoudias, Helen
    Paul, Eldho
    Clements, Warren J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (03) : 451 - 461
  • [33] An invariant approach for image registration in digital subtraction angiography
    Bentoutou, Y
    Taleb, N
    El Mezouar, MC
    Taleb, M
    Jetto, L
    PATTERN RECOGNITION, 2002, 35 (12) : 2853 - 2865
  • [34] Subtraction coronary computed tomography in patients with severe calcification
    Amanuma, Makoto
    Kondo, Takeshi
    Sano, Tomonari
    Sekine, Takako
    Takayanagi, Tomoya
    Matsutani, Hideyuki
    Arai, Takehiro
    Morita, Hitomi
    Ishizaka, Kazumasa
    Arakita, Kazumasa
    Iwasa, Akiko
    Takase, Shinichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (08) : 1635 - 1642
  • [35] Effects of Lung Injury on Regional Aeration and Expiratory Time Constants: Insights From Four-Dimensional Computed Tomography Image Registration
    Herrmann, Jacob
    Gerard, Sarah E.
    Shao, Wei
    Xin, Yi
    Cereda, Maurizio
    Reinhardt, Joseph M.
    Christensen, Gary E.
    Hoffman, Eric A.
    Kaczka, David W.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [36] Quantitative Iodine-123 single-photon emission computed tomography/computed tomography for Iodine-131 therapy of an autonomously functioning thyroid nodule
    Lee, Won Woo
    Song, Yoo Sung
    So, Young
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2023, 7 (01):
  • [37] Improving the Image Quality in Computed Tomographic Pulmonary Angiography With Dual-Energy Subtraction: A New Application of Spectral Computed Tomography
    Bai, Aiguo
    Sun, Yibo
    Qi, Lin
    Yang, Yanli
    Hua, Yanqing
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (05) : 718 - 724
  • [38] The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry
    Brouwer, Charlotte L.
    Kierkels, Roel G. J.
    van 't Veld, Aart A.
    Sijtsema, Nanna M.
    Meertens, Harm
    RADIATION ONCOLOGY, 2014, 9
  • [39] Subtraction coronary computed tomography in patients with severe calcification
    Makoto Amanuma
    Takeshi Kondo
    Tomonari Sano
    Takako Sekine
    Tomoya Takayanagi
    Hideyuki Matsutani
    Takehiro Arai
    Hitomi Morita
    Kazumasa Ishizaka
    Kazumasa Arakita
    Akiko Iwasa
    Shinichi Takase
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1635 - 1642
  • [40] Facile Hydrothermal Synthesis of an Iodine-Doped Computed Tomography Contrast Agent Using Insoluble Triiodobenzene
    Jeong, Yohan
    Shin, Heejun
    Na, Kun
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2020, 6 (12) : 6961 - 6970