Computed tomography lung iodine contrast mapping by image registration and subtraction

被引:5
|
作者
Goatman, Keith [1 ]
Plakas, Costas [1 ]
Schuijf, Joanne [2 ]
Beveridge, Erin [1 ]
Prokop, Mathias [3 ]
机构
[1] Toshiba Med Visualizat Syst, Edinburgh, Midlothian, Scotland
[2] Toshiba Med Syst Europe, Zoetermeer, Netherlands
[3] UMC, Dept Radiol, Nijmegen, Netherlands
来源
MEDICAL IMAGING 2014: IMAGE PROCESSING | 2014年 / 9034卷
关键词
Medical imaging; Registration; Subtraction; Lung; CT; NONRIGID REGISTRATION; PULMONARY-EMBOLISM; DIAGNOSIS;
D O I
10.1117/12.2043551
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aqui lion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57 mm (range 1.43-4 34 mm), and following registration the mean error was 0.54 mm (range 0.44-0.64 mm) The mean surface error distance was 1.89 mm before registration and 0.47 mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction iodine mapping.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Using Z-Axis Shifting Alignment Co-Registration with Computed Tomography and Positron Emission Tomography Brain Image
    Lo, Rong-Chin
    Cheng, Wen-Yao
    Huang, Wen-Lin
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1813 - 1817
  • [22] Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration
    Ellis, R
    ToksvigLarsen, S
    Marcacci, M
    Caramella, D
    Fadda, M
    INVESTIGATIVE RADIOLOGY, 1996, 31 (10) : 658 - 667
  • [23] Computed tomography numbers obtained for varying iodine contrast concentrations by different-generation dual-energy computed tomography scanners
    Tsukamoto, Tomokatsu
    Masuda, Takanori
    Takahata, Takashi
    Kawamoto, Yoshinori
    Uenaka, Osamu
    Mori, Hiroki
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (14) : 1358 - 1364
  • [24] Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration
    Cunliffe, Alexandra R.
    Al-Hallaq, Hania A.
    Labby, Zacariah E.
    Pelizzari, Charles A.
    Straus, Christopher
    Sensakovic, William F.
    Ludwig, Michelle
    Armato, Samuel G., III
    MEDICAL PHYSICS, 2012, 39 (08) : 4679 - 4690
  • [25] Image Fusion in Dual Energy Computed Tomography Effect on Contrast Enhancement, Signal-to-Noise Ratio and Image Quality in Computed Tomography Angiography
    Behrendt, Florian F.
    Schmidt, Bernhard
    Plumhans, Cedric
    Keil, Sebastian
    Woodruff, Seth G.
    Ackermann, Diana
    Muehlenbruch, Georg
    Flohr, Thomas
    Guenther, Rolf W.
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 1 - 6
  • [26] Morphology of the Aging Lung on Computed Tomography
    Copley, Susan J.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (03) : 140 - 150
  • [27] Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms and metrics
    Yamamoto, Tokihiro
    Kabus, Sven
    Klinder, Tobias
    von Berg, Jens
    Lorenz, Cristian
    Loo, Billy W., Jr.
    Keall, Paul J.
    MEDICAL PHYSICS, 2011, 38 (03) : 1348 - 1358
  • [28] Imaging Regional Lung Structure and Function in Small Animals Using Synchrotron Radiation Phase-Contrast and K-Edge Subtraction Computed Tomography
    Bayat, Sam
    Fardin, Luca
    Cercos-Pita, Jose Luis
    Perchiazzi, Gaetano
    Bravin, Alberto
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [29] Lung tumor reproducibility with active breath control (ABC) in image-guided radiotherapy based on cone-beam computed tomography with two registration methods
    Wang, Xin
    Zhong, Renming
    Bai, Sen
    Xu, Qingfeng
    Zhao, Yaqin
    Wang, Jin
    Jiang, Xiaoqin
    Shen, Yali
    Xu, Feng
    Wei, Yuquan
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 148 - 154
  • [30] Image registration by normalized mapping
    Wang, Qi
    Zou, Cuiming
    Yuan, Yuan
    Lu, Hongbing
    Yan, Pingkun
    NEUROCOMPUTING, 2013, 101 : 181 - 189