Computed tomography lung iodine contrast mapping by image registration and subtraction

被引:5
|
作者
Goatman, Keith [1 ]
Plakas, Costas [1 ]
Schuijf, Joanne [2 ]
Beveridge, Erin [1 ]
Prokop, Mathias [3 ]
机构
[1] Toshiba Med Visualizat Syst, Edinburgh, Midlothian, Scotland
[2] Toshiba Med Syst Europe, Zoetermeer, Netherlands
[3] UMC, Dept Radiol, Nijmegen, Netherlands
来源
MEDICAL IMAGING 2014: IMAGE PROCESSING | 2014年 / 9034卷
关键词
Medical imaging; Registration; Subtraction; Lung; CT; NONRIGID REGISTRATION; PULMONARY-EMBOLISM; DIAGNOSIS;
D O I
10.1117/12.2043551
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aqui lion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57 mm (range 1.43-4 34 mm), and following registration the mean error was 0.54 mm (range 0.44-0.64 mm) The mean surface error distance was 1.89 mm before registration and 0.47 mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction iodine mapping.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Lung iodine mapping by subtraction with image registration allowing for tissue sliding
    Mohr, Brian
    Brink, Monique
    Oostveen, Luuk J.
    Schuijf, Joanne D.
    Prokop, Mathias
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [2] Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Kouchi, Takanori
    Fukuyama, Naoki
    Yokoi, Takahiro
    Uetani, Teruyoshi
    Yamashita, Natsumi
    Miyagawa, Masao
    Mochizuki, Teruhito
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1285 - 1292
  • [3] Radiation dose and image quality in K-edge subtraction computed tomography of lung in vivo
    Strengell, S.
    Keyrilainen, J.
    Suortti, P.
    Bayat, S.
    Sovijarvi, A. R. A.
    Porra, L.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1305 - 1313
  • [4] Differentiation of Intracerebral Tumor Entities with Quantitative Contrast Attenuation and Iodine Mapping in Dual-Layer Computed Tomography
    Borggrefe, Jan
    Gebest, Max Philipp
    Hauger, Myriam
    Ruess, Daniel
    Mpotsaris, Anastasios
    Kabbasch, Christoph
    Pennig, Lenhard
    Laukamp, Kai Roman
    Goertz, Lukas
    Kroeger, Jan Robert
    Doerner, Jonas
    DIAGNOSTICS, 2022, 12 (10)
  • [5] A Literature Survey of Ultrasound and Computed Tomography-Based Cardiac Image Registration
    Ming, Chieng Thion
    Omar, Zaid
    Mahmood, Nasrul Humaimi
    Kadiman, Suhaini
    JURNAL TEKNOLOGI, 2015, 74 (06): : 93 - 101
  • [6] Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography
    Zhang, Jin
    Yi, Byongyong
    Lasio, Giovanni
    Suntharalingam, Mohan
    Yu, Cedric
    MEDICAL PHYSICS, 2009, 36 (10) : 4433 - 4439
  • [7] Effect of Computed Tomography Scanning Parameters on Gold Nanoparticle and Iodine Contrast
    Galper, Merav Weill
    Saung, May Tun
    Fuster, Valentin
    Roessl, Ewald
    Thran, Axel
    Proksa, Roland
    Fayad, Zahi Adel
    Cormode, David Peter
    INVESTIGATIVE RADIOLOGY, 2012, 47 (08) : 475 - 481
  • [8] A Novel Image Segmentation Technique for Lung Computed Tomography Images
    Bong, Chin Wei
    Lam, Hong Yoong
    Kamarulzaman, Hamzah
    KNOWLEDGE TECHNOLOGY, 2012, 295 : 103 - +
  • [9] "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
    Yuan, Zilong
    Rong, Yi
    Benedict, Stanley H.
    Daly, Megan E.
    Qiu, Jianfeng
    Yamamoto, Tokihiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 88 - 94
  • [10] Image registration for digital subtraction angiography
    Meijering, EHW
    Zuiderveld, KJ
    Viergever, MA
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 1999, 31 (2-3) : 227 - 246