Spectroscopy-supported frame-based image-guided stereotactic biopsy of parenchymal brain lesions: Comparative evaluation of diagnostic yield and diagnostic accuracy

被引:26
|
作者
Chernov, Mikhail F. [1 ,2 ,4 ]
Muragaki, Yoshihiro [2 ,4 ]
Ochiai, Taku [2 ]
Taira, Takaomi [2 ]
Ono, Yuko [3 ]
Usukura, Masao [3 ]
Maruyama, Takashi [2 ,4 ]
Nakaya, Kotaro [2 ]
Nakamura, Ryoichi [4 ]
Iseki, Hiroshi [2 ,4 ]
Kubo, Osami [2 ]
Hori, Tomokatsu [2 ]
Takakura, Kintomo [2 ,4 ]
机构
[1] Tokyo Womens Med Univ, IREIIMS, Shinjuku Ku, Tokyo 1628666, Japan
[2] Tokyo Womens Med Univ, Neurol Inst, Dept Neurosurg, Tokyo 1628666, Japan
[3] Tokyo Womens Med Univ, Neurol Inst, Dept Neuroradiol, Tokyo 1628666, Japan
[4] Tokyo Womens Med Univ, Fac Adv Technosurg, Inst Adv Biomed Engn & Sci, Tokyo 1628666, Japan
关键词
Brain tumor; Stereotactic biopsy; Diagnostic yield; Diagnostic accuracy; Metabolic imaging; Proton magnetic resonance spectroscopy; MAGNETIC-RESONANCE-SPECTROSCOPY; POSITRON-EMISSION-TOMOGRAPHY; PROTON MR-SPECTROSCOPY; SPECIAL ATTENTION; CEREBRAL GLIOMAS; MASS LESIONS; TUMORS; GRADE; DIFFERENTIATION; RESECTION;
D O I
10.1016/j.clineuro.2009.03.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Comparative evaluation of diagnostic efficacy of stereotactic brain biopsy performed with and without additional use of spectroscopic imaging (H-1-MRS) for target selection was done. Methods: From 2002 to 2006, 30 patients with parenchymal brain lesions underwent H-1-MRS-supported frame-based stereotactic biopsy, whereas in 39 others MRI-guided technique was used. Comparison of diagnostic yield of the procedure in these two groups was performed. Additionally, the diagnostic accuracy was evaluated in 37 lesions, which were surgically resected within 1 month thereafter. Results: Stereotactic biopsy permitted establishment of a definitive histopathological diagnosis in 57 cases and diagnosis of low-grade glioma without specific tumor typing in 8 cases. In 4 cases tissue sampling was non-diagnostic. in 5 out of 8 cases with incomplete diagnosis and in all non-diagnostic cases target selection was performed without the use of H-1-MRS (P = 0.2073). The diagnostic yields of H-1-MRS-supported and MRI-guided procedures were 100% and 90%, respectively (P = 0.1268). Comparison of the histopathological diagnoses after stereotactic biopsy and surgical resection revealed complete diagnostic agreement in 13 cases, minor disagreement in 14 cases, and major disagreement in 10 cases. Among these last 10 cases, initial undergrading of non-enhancing WHO grade III gliomas was the most common (7 cases). The diagnostic accuracy of H-1-MRS-supported and MRI-guided procedures was 67% and 79%, respectively (P = 0.4756). Conclusion: While in the present study the diagnostic yield of H-1-MRS-supported frame-based stereotactic brain biopsy was 100%, its statistically significant diagnostic advantages over MRI-guided technique were not proved. Optimal selection of the spectroscopic target for tissue sampling remains unclear. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 535
页数:9
相关论文
共 16 条
  • [11] Evaluation of 126 Consecutive Stereotactic Procedures: Brain Biopsy, Diagnostic Yield, Accuracy, Non-Diagnostic Results, Complications and Follow-up
    Hakan, Tayfun
    Vardar Aker, Fugen
    TURKISH NEUROSURGERY, 2016, 26 (06) : 890 - 899
  • [12] Frame-based stereotactic biopsy of deep-seated and midline structures in 511 procedures: feasibility, risk profile, and diagnostic yield
    Christina A. Hamisch
    Jana Minartz
    Tobias Blau
    Vanessa Hafkemeyer
    Daniel Rueß
    Alexandra Hellerbach
    Stefan J. Grau
    Maximilian I. Ruge
    Acta Neurochirurgica, 2019, 161 : 2065 - 2071
  • [13] Frame-based stereotactic biopsy of deep-seated and midline structures in 511 procedures: feasibility, risk profile, and diagnostic yield
    Hamisch, Christina A.
    Minartz, Jana
    Blau, Tobias
    Hafkemeyer, Vanessa
    Ruess, Daniel
    Hellerbach, Alexandra
    Grau, Stefan J.
    Ruge, Maximilian I.
    ACTA NEUROCHIRURGICA, 2019, 161 (10) : 2065 - 2071
  • [14] Percutaneous image-guided needle biopsy of clavicle lesions: a retrospective study of diagnostic yield with description of safe biopsy routes in 55 cases
    Pressney, I.
    Saifuddin, A.
    SKELETAL RADIOLOGY, 2015, 44 (04) : 497 - 503
  • [15] Diagnostic Yield of Percutaneous Image-Guided Tissue Biopsy of Focal Hepatic Lesions in Cancer Patients Ten Percent Are Not Metastases From the Primary Malignancy
    Elsayes, Khaled M.
    Ellis, James H.
    Elkhouly, Tohamy
    Ream, Justin M.
    Bowerson, Michyla
    Khan, Asra
    Caoili, Elaine M.
    CANCER, 2011, 117 (17) : 4041 - 4048
  • [16] Diagnostic accuracy of fine needle aspiration cytology and core needle biopsy in bone and soft tissue tumor: A comparative study of the image-guided and blindly performed procedure
    Ariizumi, Takashi
    Kawashima, Hiroyuki
    Yamagishi, Tetsuro
    Oike, Naoki
    Murayama, Yudai
    Umezu, Hajime
    Endo, Naoto
    Ogose, Akira
    ANNALS OF DIAGNOSTIC PATHOLOGY, 2022, 59