Spectroscopy-supported frame-based image-guided stereotactic biopsy of parenchymal brain lesions: Comparative evaluation of diagnostic yield and diagnostic accuracy

被引:26
|
作者
Chernov, Mikhail F. [1 ,2 ,4 ]
Muragaki, Yoshihiro [2 ,4 ]
Ochiai, Taku [2 ]
Taira, Takaomi [2 ]
Ono, Yuko [3 ]
Usukura, Masao [3 ]
Maruyama, Takashi [2 ,4 ]
Nakaya, Kotaro [2 ]
Nakamura, Ryoichi [4 ]
Iseki, Hiroshi [2 ,4 ]
Kubo, Osami [2 ]
Hori, Tomokatsu [2 ]
Takakura, Kintomo [2 ,4 ]
机构
[1] Tokyo Womens Med Univ, IREIIMS, Shinjuku Ku, Tokyo 1628666, Japan
[2] Tokyo Womens Med Univ, Neurol Inst, Dept Neurosurg, Tokyo 1628666, Japan
[3] Tokyo Womens Med Univ, Neurol Inst, Dept Neuroradiol, Tokyo 1628666, Japan
[4] Tokyo Womens Med Univ, Fac Adv Technosurg, Inst Adv Biomed Engn & Sci, Tokyo 1628666, Japan
关键词
Brain tumor; Stereotactic biopsy; Diagnostic yield; Diagnostic accuracy; Metabolic imaging; Proton magnetic resonance spectroscopy; MAGNETIC-RESONANCE-SPECTROSCOPY; POSITRON-EMISSION-TOMOGRAPHY; PROTON MR-SPECTROSCOPY; SPECIAL ATTENTION; CEREBRAL GLIOMAS; MASS LESIONS; TUMORS; GRADE; DIFFERENTIATION; RESECTION;
D O I
10.1016/j.clineuro.2009.03.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Comparative evaluation of diagnostic efficacy of stereotactic brain biopsy performed with and without additional use of spectroscopic imaging (H-1-MRS) for target selection was done. Methods: From 2002 to 2006, 30 patients with parenchymal brain lesions underwent H-1-MRS-supported frame-based stereotactic biopsy, whereas in 39 others MRI-guided technique was used. Comparison of diagnostic yield of the procedure in these two groups was performed. Additionally, the diagnostic accuracy was evaluated in 37 lesions, which were surgically resected within 1 month thereafter. Results: Stereotactic biopsy permitted establishment of a definitive histopathological diagnosis in 57 cases and diagnosis of low-grade glioma without specific tumor typing in 8 cases. In 4 cases tissue sampling was non-diagnostic. in 5 out of 8 cases with incomplete diagnosis and in all non-diagnostic cases target selection was performed without the use of H-1-MRS (P = 0.2073). The diagnostic yields of H-1-MRS-supported and MRI-guided procedures were 100% and 90%, respectively (P = 0.1268). Comparison of the histopathological diagnoses after stereotactic biopsy and surgical resection revealed complete diagnostic agreement in 13 cases, minor disagreement in 14 cases, and major disagreement in 10 cases. Among these last 10 cases, initial undergrading of non-enhancing WHO grade III gliomas was the most common (7 cases). The diagnostic accuracy of H-1-MRS-supported and MRI-guided procedures was 67% and 79%, respectively (P = 0.4756). Conclusion: While in the present study the diagnostic yield of H-1-MRS-supported frame-based stereotactic brain biopsy was 100%, its statistically significant diagnostic advantages over MRI-guided technique were not proved. Optimal selection of the spectroscopic target for tissue sampling remains unclear. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:527 / 535
页数:9
相关论文
共 16 条
  • [1] Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based technique
    Woodworth, GF
    McGirt, MJ
    Samdani, A
    Garonzik, I
    Olivi, A
    Weingart, JD
    JOURNAL OF NEUROSURGERY, 2006, 104 (02) : 233 - 237
  • [2] The accuracy and diagnostic yield of computerized tomography guided stereotactic biopsy in brain lesions
    Calisaneller, Tarkan
    Ozdemir, Ozgur
    Ozger, Ozkan
    Ozen, Ozlem
    Kiyic, Halil
    Caner, Hakan
    Altinoers, Nur
    TURKISH NEUROSURGERY, 2008, 18 (01) : 17 - 22
  • [3] Related factors with diagnostic yield and intracranial hemorrhagic complications in frame-based stereotactic biopsy. Review
    Lara-Almunia, Monica
    Hernandez-Vicente, Javier
    NEUROCIRUGIA, 2021, 32 (06): : 285 - 294
  • [4] Frame-based Stereotactic Biopsy: Description and Association of Anatomical, Radiologic, and Surgical Variables with Diagnostic Yield in a Series of 407 Cases
    Lara-Almunia, Monica
    Hernandez-Vicente, Javier
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2019, 80 (03) : 149 - 161
  • [5] Diagnostic impact of proton MR-spectroscopy versus image-guided stereotactic biopsy
    Setzer, M.
    Herminghaus, S.
    Marquardt, G.
    Tews, D. S.
    Pilatus, U.
    Seifert, V.
    Zanella, F.
    Lanfermann, H.
    ACTA NEUROCHIRURGICA, 2007, 149 (04) : 379 - 386
  • [6] Diagnostic yield and concordance of image-guided biopsy in musculoskeletal lesions
    Wong, Hayley
    Tarr, Gregory P.
    Anand, Rahul
    Atkinson, Nicola
    Flint, Michael
    Clarke, Andrew
    Symmans, Pennie
    Doyle, Anthony
    SKELETAL RADIOLOGY, 2024, 53 (01) : 75 - 84
  • [7] The Safety and Diagnostic Value of Frame-Based and CT-Guided Stereotactic Brain Biopsy Technique
    Ersahin, Mehmet
    Karaaslan, Numan
    Gurbuz, Mehmet Sabri
    Hakan, Tayfun
    Berkman, Mehmet Zafer
    Ekinci, Osman
    Denizli, Nazim
    Aker, Fugen Vardar
    TURKISH NEUROSURGERY, 2011, 21 (04) : 582 - 590
  • [8] Frameless image-guided stereotactic brain biopsies: emphasis on diagnostic yield
    Sodaba Khatab
    Wim Spliet
    Peter A. Woerdeman
    Acta Neurochirurgica, 2014, 156 : 1441 - 1450
  • [9] Frameless image-guided stereotactic brain biopsies: emphasis on diagnostic yield
    Khatab, Sodaba
    Spliet, Wim
    Woerdeman, Peter A.
    ACTA NEUROCHIRURGICA, 2014, 156 (08) : 1441 - 1450
  • [10] Diagnostic yield and accuracy of paediatric image-guided fine needle aspiration biopsy of deep organ tumours
    Bondera, Tichayedza
    Schubert, Pawel
    van Zyl, Anel
    Pitcher, Richard
    Bagadia, Asif
    SA JOURNAL OF RADIOLOGY, 2022, 26 (01):