Elastic Optical Fiber Fabry-Perot Interferometer for Highly Sensitive AC Magnetic Field Measurement

被引:16
作者
Chen, Xiaolu [1 ]
Wu, Shengnan [1 ,2 ]
Zeng, Yilong [1 ]
Zhou, Bin [1 ]
Wang, Liang [3 ]
Liu, Liu [1 ]
He, Sailing [1 ,2 ]
机构
[1] South China Normal Univ, South China Acad Adv Optoelect, Guangzhou 510631, Guangdong, Peoples R China
[2] Zhejiang Univ, Ctr Opt & Electromagnet Res, State Key Lab Modern Opt Instrumentat, Hangzhou 310058, Zhejiang, Peoples R China
[3] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
关键词
AC magnetic field measurement; elastic fiber Fabry-Perot interferometer; PDMS; soft splicing; sensitivity enhancement; SENSORS; LASER;
D O I
10.1109/JSEN.2018.2841370
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have proposed and demonstrated a novel elastic optical fiber Fabry-Perot interferometer (FPI)-based ac magnetic field sensor with high magnetic sensitivity and correction of temperature crosstalk. The elastic FPI is formed by soft splicing using low Young's modulus polydimethylsiloxane material at the joint point of a hollow-core fiber and single-mode fibers and is fixed on a common supermendur rod, a kind of magnetostrictive material. AC magnetic field-induced length change of the magnetostrictive rod results in the obvious change of the FPI cavity length and finally is transduced to the intensity variation of the sensor signal, which makes the sensor highly sensitive to ac magnetic field. Taking advantage of the elastic FPI structure, the magnetic sensitivity (in terms of strain) is improved to 48 ppm/mT (75.01 pm/mT in terms of wavelength), compared with the low intrinsic sensitivity of the conventional magnetostrictive rod (usually below several ppm/mT and 0.39 ppm/mT in our case). Moreover, the impact of temperature cross-sensitivity is removed by retrieving the wavelength shift of the FPI interference spectrum based on the calibrated signal voltage versus wavelength shift. All the ac magnetic fields of different frequencies and intensities have been successfully detected and measured by our FPI sensor without the impact of temperature crosstalk. We believe such a simple, compact, and cost-effective sensor would be a promising candidate for accurate monitoring of ac magnetic field.
引用
收藏
页码:5799 / 5804
页数:6
相关论文
共 21 条
  • [1] High-resolution measurements of the spatial and temporal evolution of megagauss magnetic fields created in intense short-pulse laser-plasma interactions
    Chatterjee, Gourab
    Singh, Prashant Kumar
    Adak, Amitava
    Lad, Amit D.
    Kumar, G. Ravindra
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01)
  • [2] Compensation of hysteresis in magnetic field sensors employing Fiber Bragg Grating and magneto-elastic materials
    Davino, D.
    Visone, C.
    Ambrosino, C.
    Campopiano, S.
    Cusano, A.
    Cutolo, A.
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2008, 147 (01) : 127 - 136
  • [3] MAGNETO-OPTICAL FIBER SENSORS FOR ELECTRICAL INDUSTRY - ANALYSIS OF PERFORMANCES
    DONATI, S
    ANNOVAZZILODI, V
    TAMBOSSO, T
    [J]. IEE PROCEEDINGS-J OPTOELECTRONICS, 1988, 135 (05): : 372 - 382
  • [4] Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility
    Fuard, D.
    Tzvetkova-Chevolleau, T.
    Decossas, S.
    Tracqui, P.
    Schiavone, P.
    [J]. MICROELECTRONIC ENGINEERING, 2008, 85 (5-6) : 1289 - 1293
  • [5] A review of shape memory alloy research, applications and opportunities
    Jani, Jaronie Mohd
    Leary, Martin
    Subic, Aleksandar
    Gibson, Mark A.
    [J]. MATERIALS & DESIGN, 2014, 56 : 1078 - 1113
  • [6] Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
    Johnston, I. D.
    McCluskey, D. K.
    Tan, C. K. L.
    Tracey, M. C.
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (03)
  • [7] Rail Inspection Meets Big Data: Methods and Trends
    Li, Qingyong
    Zhong, Zhangdui
    Liang, Zhengping
    Liang, Yong
    [J]. PROCEEDINGS 2015 18TH INTERNATIONAL CONFERENCE ON NETWORK-BASED INFORMATION SYSTEMS (NBIS 2015), 2015, : 302 - 308
  • [8] High sensitivity rotating alternating current field measurement for arbitrary-angle underwater cracks
    Li, Wei
    Yuan, Xin'an
    Chen, Guoming
    Ge, Jiuhao
    Yin, Xiaokang
    Li, Kongjing
    [J]. NDT & E INTERNATIONAL, 2016, 79 : 123 - 131
  • [9] Magnetostrictive composite-fiber Bragg grating (MC-FBG) magnetic field sensor
    Liu, Heliang
    Or, Siu Wing
    Tam, Hwa Yaw
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2012, 173 (01) : 122 - 126
  • [10] Magnetic Sensors Based on Amorphous Ferromagnetic Materials: A Review
    Moron, Carlos
    Cabrera, Carolina
    Moron, Alberto
    Garcia, Alfonso
    Gonzalez, Mercedes
    [J]. SENSORS, 2015, 15 (11) : 28340 - 28366