Brain and Head-and-Neck MRI in Immobilization Mask: A Practical Solution for MR-Only Radiotherapy

被引:13
|
作者
Mandija, Stefano [1 ,2 ]
D'Agata, Federico [1 ,2 ,3 ]
Navest, Robin J. M. [1 ,2 ]
Sbrizzi, Alessandro [1 ,2 ]
Tijssen, Rob H. N. [2 ]
Philippens, Marielle E. P. [2 ]
Raaijmakers, Cornelis P. J. [2 ]
Seravalli, Enrica [2 ]
Verhoeff, Joost J. C. [2 ]
Lagendijk, Jan J. W. [2 ]
van den Berg, Cornelis A. T. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Computat Imaging Grp MRI Diagnost & Therapy, Ctr Image Scienoes, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[3] Univ Turin, Dept Neurosci, Turin, Italy
来源
FRONTIERS IN ONCOLOGY | 2019年 / 9卷
关键词
brain; head-and-neck; immobilization mask; MR-only; radiotherapy; COMPUTED-TOMOGRAPHY GENERATION; MAGNETIC-RESONANCE; RADIATION-THERAPY; CANCER; DELINEATION; ACCURACY; MOVEMENT; QUALITY;
D O I
10.3389/fonc.2019.00647
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In brain/head-and-neck radiotherapy (RT), thermoplastic immobilization masks guarantee reproducible patient positioning in treatment position between MRI, CT, and irradiation. Since immobilization masks do not fit in the diagnostic MR head/head-and-neck coils, flexible surface coils are used for MRI imaging in clinical practice. These coils are placed around the head/neck, in contact with the immobilization masks. However, the positioning of these flexible coils is technician dependent, thus leading to poor image reproducibility. Additionally, flexible surface coils have an inferior signal-to-noise-ratio (SNR) compared to diagnostic coils. The aim of this work was to create a new immobilization setup which fits into the diagnostic MR coils in order to enhance MR image quality and reproducibility. For this purpose, a practical immobilization setup was constructed. The performances of the standard clinical and the proposed setups were compared with four tests: SNR, image quality, motion restriction, and reproducibility of inter-fraction subject positioning. The new immobilization setup resulted in 3.4 times higher SNR values on average than the standard setup, except directly below the flexible surface coils where similar SNR was observed. Overall, the image quality was superior for brain/head-and-neck images acquired with the proposed RT setup. Comparable motion restriction in feet-head/left-right directions (maximum motion approximate to 1 mm) and comparable inter-fraction repositioning accuracy (mean inter-fraction movement 1 +/- 0.5 mm) were observed for the standard and the new setup.
引用
收藏
页数:8
相关论文
共 30 条
  • [1] Minimal mask immobilization with optical surface guidance for head and neck radiotherapy
    Zhao, Bo
    Maquilan, Genevieve
    Jiang, Steve
    Schwartz, David L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 17 - 24
  • [2] Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy
    Lauwers, Iris
    Capala, Marta
    Kaushik, Sandeep
    Rusko, Laszlo
    Cozzini, Cristina
    Kleijnen, Jean-Paul
    Wyatt, Jonathan
    McCallum, Hazel
    Verduijn, Gerda
    Wiesinger, Florian
    Hernandez-Tamames, Juan
    Petit, Steven
    RADIOTHERAPY AND ONCOLOGY, 2025, 205
  • [3] Validation of the dosimetric and geometric accuracy of MR-only treatment planning solution for prostate cancer radiotherapy
    Posiewnik, Michal
    Piotrowski, Tomasz
    WSPOLCZESNA ONKOLOGIA-CONTEMPORARY ONCOLOGY, 2021, 25 (04): : 241 - 245
  • [4] A combined automatic MR OAR contouring and synthetic CT solution for prostate MR-only radiotherapy
    Wyatt, Jonathan J.
    Kaushik, Sandeep
    Cozzini, Cristina
    Kolozsvari, Bernadett
    Deak-Karancsi, Borbala
    Pearson, Rachel A.
    Petit, Steven
    Capala, Marta
    Hernandez-Tamames, Juan A.
    Hideghety, Katalin
    Maxwell, Ross J.
    Rusko, Laszlo
    Wiesinger, Florian
    McCallum, Hazel M.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3144 - S3147
  • [5] Patch-based generative adversarial neural network models for head and neck MR-only planning
    Klages, Peter
    Benslimane, Ilyes
    Riyahi, Sadegh
    Jiang, Jue
    Hunt, Margie
    Deasy, Joseph O.
    Veeraraghavan, Harini
    Tyagi, Neelam
    MEDICAL PHYSICS, 2020, 47 (02) : 626 - 642
  • [6] Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR-only radiotherapy planning in brain tumors?
    Lui, Jeffrey C. F.
    Lee, Francis K. H.
    Law, C. C.
    Chow, James C. H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [7] Dosimetric evaluation of synthetic CT image generated using a neural network for MR-only brain radiotherapy
    Tang, Bin
    Wu, Fan
    Fu, Yuchuan
    Wang, Xianliang
    Wang, Pei
    Orlandini, Lucia Clara
    Li, Jie
    Hou, Qing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 55 - 62
  • [8] Assessment of image quality of a radiotherapy-specific hardware solution for PET/MRI in head and neck cancer patients
    Winter, Rene M.
    Leibfarth, Sara
    Schmidt, Holger
    Zwirner, Kerstin
    Moennich, David
    Welz, Stefan
    Schwenzer, Nina F.
    la Fougere, Christian
    Nikolaou, Konstantin
    Gatidis, Sergios
    Zips, Daniel
    Thorwarth, Daniela
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (03) : 485 - 491
  • [9] Head-and-Neck MRI-only radiotherapy treatment planning: From acquisition in treatment position to pseudo-CT generation
    Largent, A.
    Marage, L.
    Gicquiau, I
    Nunes, J-C
    Reynaert, N.
    Castelli, J.
    Chajon, E.
    Acosta, O.
    Gambarota, G.
    de Crevoisier, R.
    Saint-Jalmes, H.
    CANCER RADIOTHERAPIE, 2020, 24 (04): : 288 - 297
  • [10] Assessing multiple MRI sequences in deep learning-based synthetic CT generation for MR-only radiation therapy of head and neck cancers
    Antunes, Jacob
    Young, Tony
    Pittock, Dane
    Jacobs, Paul
    Nelson, Aaron
    Piper, Jon
    Deshpande, Shrikant
    RADIOTHERAPY AND ONCOLOGY, 2025, 205