Quadruple hamstring anterior cruciate ligament reconstruction: A multicenter study

被引:31
作者
Scranton, PE
Bagenstose, JE
Lantz, BA
Friedman, MJ
Khalfayan, EE
Auld, MK
机构
[1] Orthoped Int, Seattle, WA USA
[2] Orthopaed Inst Ohio, Lima, OH USA
[3] So Calif Orthoped Inst, Van Nuys, CA USA
[4] Orthoped Hlth Care NW, Eugene, OR USA
关键词
anterior cruciate ligament; quadruple; multicenter study; interference fixation;
D O I
10.1053/jars.2002.35262
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The use of blunt-threaded titanium interference screws for arthroscopic-assisted fixation of a quadruple-strand hamstring anterior cruciate ligament (ACL) reconstruction has recently been reported. However, the pitfalls of the low medial portal technique, rehabilitation protocol, and long-term results have not. The purpose of this multicenter study was to prospectively evaluate this technique's application to ACL instability in symptomatic patients as well as to develop a standardized rehabilitation protocol. Type of Study: Observation cohort study. Methods: One hundred-twenty patients had quadruple hamstring ACL reconstructions, followed the study protocol, and were seen at 2 years follow-up. They were evaluated using Lysholm score, Lachman test, anterior drawer test, pivot-shift test, KT-1000, effusion assessment, and the Tegner Sports Activity Scale. Results: The average Lysholm score improved 42 points; Lachman test, effusion assessment, anterior drawer test, KT-1000, and Tegner Sports Activity Scale scores all improved. Of 120 ACL reconstructions, 5 failed. Of these, 3 failed from new late injury, 1 from technical error, and 1 from patient nonadherence to rehabilitation protocol. Some anterior knee pain was present in 30% of patients, and 22% had at some time experienced hamstring pain that did not interfere with athletic activity. Conclusions: This multicenter study reports success with quadruple hamstring ACL reconstruction using the low medial portal technique. Specific pitfalls and a rehabilitation protocol are also discussed. Low medial portal position is critical in successful surgery. Variations in screw size to accommodate the variation in graft construct size are also recommended.
引用
收藏
页码:715 / 724
页数:10
相关论文
共 50 条
  • [31] Anthropometric correlation with hamstring graft size in anterior cruciate ligament reconstruction among males
    Moghamis, Isam
    Abuodeh, Yousef
    Darwiche, Ali
    Ibrahim, Talal
    Al Dosari, Mohammad Al Ateeq
    Ahmed, Ghalib
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (03) : 577 - 584
  • [32] Pretibial cyst formation after anterior cruciate ligament reconstruction with a hamstring tendon autograft
    Tsuda, Eiichi
    Ishibashi, Yasuyuki
    Tazawa, Koji
    Sato, Hideki
    Kusumi, Tornomi
    Toh, Satoshi
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (06) : 691.e1 - 691.e6
  • [33] Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction
    Iosif Gavriilidis
    Emilios E. Pakos
    Benjamin Wipfler
    Ioannis S. Benetos
    Hans H. Paessler
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 1043 - 1047
  • [34] Endoscopic anterior cruciate ligament reconstruction using a four strand hamstring tendon construct
    Deehan, DJ
    Pinczewski, LA
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 2002, 47 (01): : 428 - 436
  • [35] The Use of Hamstring Fatigue to Reduce Quadriceps Inhibition After Anterior Cruciate Ligament Reconstruction
    Lowe, Timothy
    Dong, Xuanliang Neil
    PERCEPTUAL AND MOTOR SKILLS, 2018, 125 (01) : 81 - 92
  • [36] Hamstring tendon anterior cruciate ligament reconstruction: does gracilis tendon harvest matter?
    Björn Barenius
    Webster Kate Webster
    Jodie McClelland
    Julian Feller
    International Orthopaedics, 2013, 37 : 207 - 212
  • [37] Revision anterior cruciate ligament reconstruction with ipsi- or contralateral hamstring tendon grafts
    Legnani C.
    Peretti G.
    Borgo E.
    Zini S.
    Ventura A.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 533 - 537
  • [38] Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction
    Gavriilidis, Iosif
    Pakos, Emilios E.
    Wipfler, Benjamin
    Benetos, Ioannis S.
    Paessler, Hans H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (09) : 1043 - 1047
  • [39] The Effect of Autologous Hamstring Graft Diameter on the Likelihood for Revision of Anterior Cruciate Ligament Reconstruction
    Spragg, Lindsey
    Chen, Jason
    Mirzayan, Raffy
    Love, Rebecca
    Maletis, Gregory
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2016, 44 (06) : 1475 - 1481
  • [40] Intra- and extra-articular hamstring reconstruction of anterior cruciate ligament tears
    Buscayret, C
    Buscayret, F
    Farenq, C
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2001, 87 (03): : 276 - 280