共 42 条
An ultrasensitive and highly selective determination method for quinones by high-performance liquid chromatography with photochemically initiated luminol chemiluminescence
被引:44
作者:
Ahmed, Sameh
[1
,2
]
Kishikawa, Naoya
[1
]
Ohyama, Kaname
[1
]
Maki, Toshihide
[3
]
Kurosaki, Hiromasa
[4
]
Nakashima, Kenichiro
[1
]
Kuroda, Naotaka
[1
]
机构:
[1] Nagasaki Univ, Course Pharmaceut Sci, Grad Sch Biomed Sci, Nagasaki 8528521, Japan
[2] Assiut Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Assiut 71526, Egypt
[3] Nagasaki Univ, Joint Res Ctr, Nagasaki 8528521, Japan
[4] Kumamoto Univ, Grad Sch Pharmaceut Sci, Kumamoto 8620973, Japan
关键词:
Quinones;
Photochemical reaction;
Luminol chemiluminescence;
ROS;
Enhancer;
L-012;
Semiquinone radical;
ESR;
POLYCYCLIC AROMATIC-HYDROCARBONS;
TANDEM MASS-SPECTROMETRY;
DIESEL EXHAUST PARTICLES;
PARTICULATE MATTER;
FLUORESCENCE DETECTION;
VITAMIN-K;
OXYGEN;
9,10-PHENANTHRENEQUINONE;
PHOTOSENSITIZATION;
NAPHTHOQUINONES;
D O I:
10.1016/j.chroma.2009.03.016
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Quinones are a class of compounds of substantial toxicological and pharmacological interest. An ultrasensitive and highly selective chemiluminescence (CL) method was newly developed for the determination of quinones based on the utility of photochemically initiated luminol CL The method involved ultraviolet (UV) irradiation of quinones to generate reactive oxygen species (ROS) through the unique photosensitization reaction accompanied with the photolytical generation of 3,6-dihydroxyphthalic acid (DHPA) from quinones. The photoproducts were detected by luminol CL reaction. Interestingly, it was noticed that DHPA had enhancement effect for the luminol CL. The generation of the enhancer (DHPA) in association with the oxidant (ROS) in the photochemical reaction greatly increases the sensitivity and selectivity of the proposed luminol CL method. In order to elucidate the type of ROS produced by the photosensitizaion reaction in relation to the proposed CL reaction, we investigated the quenching effect of selective ROS scavengers in the luminol CL Although several ROS were generated, superoxide anion was the most effective ROS for the generated CL Moreover, the enhancement mechanism of DHPA for luminol CL was confirmed. The enhancement was found to be through the formation of stabilized semiquinone anion radical that provided long-lived CL The generation of the semiquinone radical was confirmed by electron spin resonance technique. Furthermore, we developed an HPLC method with on-line photochemical reaction followed by the proposed CL detection for the determination of four quinones. A luminol analogue, L-012, was used for its high sensitivity. The detection limits for quinones obtained with the proposed method (S/N = 3) were in the range 1.5-24 fmol that were 10-1000 times more sensitive compared with the previous methods. Finally, the developed HPLC-CL system was successfully applied for the determination of quinones in airborne particulate samples collected at Nagasaki city. (C) 2009 Elsevier B.V. All rights reserved.