Increased cyclic guanosine monophosphate levels and continuous-flow left-ventricular assist devices: Implications for gastrointestinal bleeding

被引:16
|
作者
Grosman-Rimon, Liza [1 ,2 ]
Tumiati, Laura C. [1 ]
Fuks, Avi [1 ]
Jacobs, Ira [2 ]
Lalonde, Spencer D. [1 ]
Cherney, David Z. I. [3 ]
Rao, Vivek [1 ]
机构
[1] Univ Hlth Network, Peter Munk Cardiac Ctr, Div Cardiovasc Surg, Toronto, ON, Canada
[2] Univ Toronto, Fac Kinesiol & Phys Educ, Dept Exercise Sci, Toronto, ON M5G 2C4, Canada
[3] Univ Hlth Network, Div Nephrol, Toronto, ON, Canada
关键词
continuous-flow left ventricular assist device; gastrointestinal bleeding; cyclic guanosine monophosphate; NITRIC-OXIDE SYNTHASE; VON-WILLEBRAND SYNDROME; PDGF-AB RELEASE; HEART-FAILURE; RISK-FACTORS; EXPRESSION; IMPLANTATION; RECIPIENTS; SYSTEM;
D O I
10.1016/j.jtcvs.2015.09.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We examine the hypothesis that cyclic guanosine monophosphate (cGMP) levels are elevated in recipients of continuous-flow left ventricular assist devices (CF-LVADs) and that elevated cGMP levels are associated with a risk of gastrointestinal (GI) bleeding events. Methods: The levels of cGMP, nitric oxide, platelet activation markers, platelet-derived growth factors (PDGF) AB/BB and AA, and the inflammatory mediator C-reactive protein (CRP) were examined in 19 CF-LVAD recipients, 21 patients who had heart failure, and 19 healthy control-group participants. Results: The median level of cGMP was significantly higher in CF-LVAD recipients, compared with healthy participants (6.6 vs 2.1 pmol/mL, u = 62.5; P = .001; r = -0.55). Median cGMP levels in the heart failure group (12.5 pmol/L) were higher, compared with both CF-LVAD recipients (u = 75.0; P = .001; r = -0.53) and healthy participants (u = 4.0; P < .001; r = -0.83). Compared with the healthy group, median CRP levels were significantly higher in CF-LVAD recipients (2.9 vs 8.0 mg/L; u = 58.0; P < .001; r = -0.63) and heart failure patients (2.9 vs 7.0 mg/L; u = 59.0; P < .001; r = -0.65). In the subgroup of patients supported with the HeartMate II (Thoratec Corporation, Pleasanton, Calif), pulsatility index was significantly negatively correlated with cGMP levels (r = -0.73; P < .05), indicating that low pulsatility index is associated with higher cGMP levels. High cGMP levels were significantly associated with GI bleeding events, but not with bleeding events in general. Conclusions: The primary finding of this study is that GI bleeding in CF-LVAD recipients is associated with significantly elevated cGMP levels, despite high levels of CRP, which interfere with cGMP production. Further studies are required to determine whether elevated cGMP levels can be used as a clinical marker for increased risk of GI bleeding in CF-LVAD recipients.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [1] Gastrointestinal bleeding with continuous-flow left ventricular assist devices
    Amer S.
    Shah P.
    Hassan S.
    Clinical Journal of Gastroenterology, 2015, 8 (2) : 63 - 67
  • [2] Characteristics and outcomes of gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A systematic review
    Carlson, Laura A.
    Maynes, Elizabeth J.
    Choi, Jae Hwan
    Hallett, Andrew M.
    Horan, Dylan P.
    Weber, Matthew P.
    Deb, Avijit K.
    Patel, Sinal
    Samuels, Louis E.
    Morris, Rohinton J.
    Entwistle, John W.
    Massey, H. Todd
    Tchantchaleishvili, Vakhtang
    ARTIFICIAL ORGANS, 2020, 44 (11) : 1150 - 1161
  • [3] Pharmacotherapeutic Management of Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices
    Sieg, Adam C.
    Moretz, Jeremy D.
    Horn, Edward
    Jennings, Douglas L.
    PHARMACOTHERAPY, 2017, 37 (11): : 1432 - 1448
  • [4] Gastrointestinal bleeding on continuous-flow left ventricular assist device therapy
    Hammer, Yoav
    Bitar, Abbas
    Aaronson, Keith D.
    ESC HEART FAILURE, 2023, 10 (04): : 2214 - 2224
  • [5] Continuous-Flow Left Ventricular Assist Device-Related Gastrointestinal Bleeding
    Kim, Ju H.
    Brophy, Donald F.
    Shah, Keyur B.
    CARDIOLOGY CLINICS, 2018, 36 (04) : 519 - +
  • [6] Gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices: A comprehensive review
    Del Rio-Pertuz, Gaspar
    Nair, Nandini
    ARTIFICIAL ORGANS, 2023, 47 (01) : 12 - 23
  • [7] Limited usefulness of endoscopic evaluation in patients with continuous-flow left ventricular assist devices and gastrointestinal bleeding
    Axelrad, Jordan E.
    Pinsino, Alberto
    Trinh, Pauline N.
    Thanataveerat, Anusorn
    Brooks, Christian
    Demmer, Ryan T.
    Effner, Lisa
    Parkis, Grant
    Cagliostro, Barbara
    Han, Jiho
    Garan, A. Reshad
    Topkara, Veli
    Takeda, Koji
    Takayama, Hiroo
    Naka, Yoshifumi
    Ramirez, Ivonne
    Garcia-Carrasquillo, Reuben
    Colombo, Paolo C.
    Gonda, Tamas
    Yuzefpolskaya, Melana
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (06) : 723 - 732
  • [8] Increased incidence of angiodysplasia of the gastrointestinal tract and bleeding in patients with continuous flow left ventricular assist devices (LVADs)
    Muthiah, Kavitha
    Robson, Desiree
    Macdonald, Peter S.
    Keogh, Anne M.
    Kotlyar, Eugene
    Granger, Emily
    Dhital, Kumud
    Spratt, Phillip
    Jansz, Paul
    Hayward, Christopher S.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2013, 36 (07) : 449 - 454
  • [9] Pre-Operative Right Ventricular Dysfunction Is Associated With Gastrointestinal Bleeding in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Sparrow, Christopher T.
    Nassif, Michael E.
    Raymer, David S.
    Novak, Eric
    LaRue, Shane J.
    Schilling, Joel D.
    JACC-HEART FAILURE, 2015, 3 (12) : 956 - 964
  • [10] Resource utilization and hospital readmission associated with gastrointestinal bleeding in patients with continuous-flow left ventricular assist devices
    Carnicelli, Anthony P.
    Thakkar, Anjali
    Deicicchi, David J.
    Storm, Andrew C.
    Rimsans, Jessica
    Connors, Jean M.
    Mehra, Mandeep R.
    Groarke, John D.
    Givertz, Michael M.
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2019, 47 (03) : 375 - 383