The value of performing dual-source dual-energy computed tomography in analysis strategy for urinary mixed stone

被引:0
|
作者
Wang, Xiao-Gang [1 ]
Fan, Bo [1 ]
Wang, Wei [1 ]
Jin, Yi-Ying [1 ]
Jin, Yan [2 ]
Yang, Zhi-Qiang [3 ]
Li, Xian-Cheng [1 ,4 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 2, Dept Urol, Zhongshan Rd 467, Dalian, Liaoning, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 1, Dept Lab Med, Dalian, Liaoning, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Dept Cardiac Imaging, Dalian, Liaoning, Peoples R China
[4] Dalian Med Univ, Affiliated Hosp 1, Dept Urol, Dalian, Liaoning, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY | 2017年 / 10卷 / 02期
关键词
Dual-source dual-energy computed tomography; urinary stone; stone composition; SHOCK-WAVE LITHOTRIPSY; INITIAL IN-VITRO; ACUTE FLANK PAIN; CALCIUM-OXALATE; PERCUTANEOUS NEPHROLITHOTOMY; KIDNEY-STONES; RENAL STONES; CT; DIFFERENTIATION; EXPERIENCE;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study was to characterize and explore the mixed urinary stones by using Dual-Source Dual-Energy Computed Tomography (DSDECT) in vitro. Study scanned 134 human pure and mixed stones that were embedded into fresh porcine kidneys. Image analysis of these stones gave us the mean attenuation values in Hounsfield units (HU) and dual-energy index (DEI) at 80 kVp and 140 kVp. The mean of attenuation values, dual-energy and DEI were statistically different between uric acid (UA) containing and other stones, including mixed stones. For mixed stone, COX/UA and COX/PH had significantly difference in DEI (P<0.05), and the HU of 80 kVp, 140 kVp, and dual-energy were significantly different among COX/PH and PH/UA groups. The 80 kVp HU, 140 kVp HU and dual energy HU were significantly higher in COX/PH group compared with PH/UA group (1316.31 vs 813.23, 717.60 vs 440.03, 951.49 vs 557.38, respectively). The value of 80 kVp HU, 140 kVp HU and dual energy HU in COX/UA was 1052.54, 704.12, 802.94 respectively. DSDECT was precise in the differentiation of UA-containing stones and gave promising results for mixed stones of different types.
引用
收藏
页码:1519 / 1528
页数:10
相关论文
共 50 条
  • [1] Characterization of Mixed Urinary Stone Compositions with Dual-Source Dual-Energy Computed Tomography in Vivo Compared to Infrared Spectroscopy
    Meng, Xianghu
    Sun, Xueying
    Cong, Rong
    Qi, Liang
    Wang, Zengjun
    Song, Rijin
    IRANIAN JOURNAL OF RADIOLOGY, 2021, 18 (03)
  • [2] In vitro analysis of urinary stone composition in dual-energy computed tomography
    Stepien, Monika
    Chrzan, Robert
    Gawlas, Wojciech
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E421 - E425
  • [3] Feasibility of Single-Source Dual-Energy Computed Tomography for Urinary Stone Characterization and Value of Iterative Reconstructions
    Morsbach, Fabian
    Wurnig, Moritz C.
    Mueller, Daniel
    Krauss, Bernhard
    Korporaal, Johannes Georg
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2014, 49 (03) : 125 - 130
  • [4] Determination of Renal Stone Composition in Phantom and Patients Using Single-Source Dual-Energy Computed Tomography
    Kulkarni, Naveen M.
    Eisner, Brian H.
    Pinho, Daniella F.
    Joshi, Mukta C.
    Kambadakone, Avinash R.
    Sahani, Dushyant V.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 37 - 45
  • [5] Gemstone Spectral Imaging Dual-energy Computed Tomography: A Novel Technique to Determine Urinary Stone Composition
    Li, Xiaohu
    Zhao, Ren
    Liu, Bin
    Yu, Yongqiang
    UROLOGY, 2013, 81 (04) : 727 - 730
  • [6] In Vivo Analysis of Urinary Stones With Dual-Energy Computed Tomography
    Erdogan, Hasan
    Temizoz, Osman
    Koplay, Mustafa
    Ozturk, Bahadir
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 214 - 219
  • [7] Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices
    Rudenko, Vadim
    Serova, Natalia
    Kapanadze, Lida
    Taratkin, Mark
    Okhunov, Zhamshid
    Leonard, Stephen P.
    Ritter, Manuel
    Kriegmair, Maximilian
    Snurnitsyna, Olesya
    Kozlov, Vasiliy
    Laukhtina, Ekaterina
    Arshiev, Magomed
    Aleksandrova, Ksenia
    Salomon, Georg
    Enikeev, Dmitry
    Glybochko, Petr
    JOURNAL OF ENDOUROLOGY, 2020, 34 (09) : 893 - 899
  • [8] Characterization of Urinary Stone Composition by Use of Third-Generation Dual-Source Dual-Energy CT With Increased Spectral Separation
    Duan, Xinhui
    Li, Zhoubo
    Yu, Lifeng
    Leng, Shuai
    Halaweish, Ahmed F.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (06) : 1203 - 1207
  • [9] Unsupervised deep learning based image outpainting for dual-source, dual-energy computed tomography
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [10] Correlation of dual-source computed tomography/dual-energy imaging with pathological grading of lung adenocarcinoma and its clinical value
    Jiang, Haifeng
    Li, Xiao
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2017, 33 (06) : 1429 - 1433