Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone

被引:19
|
作者
Wang, Tim [1 ]
Boone, Christopher [1 ]
Behn, Anthony W. [1 ]
Ledesma, Justin B. [1 ]
Bishop, Julius A. [1 ]
机构
[1] Stanford Univ, Med Ctr, 450 Broadway St,Pavil C,4th Fl, Palo Alto, CA 94063 USA
关键词
PULLOUT STRENGTH; HOLDING POWER; TORQUE; FIXATION; MODELS;
D O I
10.3928/01477447-20160509-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cancellous screws are designed to optimize fixation in metaphyseal bone environments; however, certain clinical situations may require the substitution of cortical screws for use in cancellous bone, such as anatomic constraints, fragment size, or available instrumentation. This study compares the biomechanical properties of commercially available cortical and cancellous screw designs in a synthetic model representing various bone densities. Commercially available, fully threaded, 4.0-mm outer-diameter cortical and cancellous screws were tested in terms of pullout strength and maximum insertion torque in standard-density and osteoporotic cancellous bone models. Pullout strength and maximum insertion torque were both found to be greater for cancellous screws than cortical screws in all synthetic densities tested. The magnitude of difference in pullout strength between cortical and cancellous screws increased with decreasing synthetic bone density. Screw displacement prior to failure and total energy absorbed during pullout strength testing were also significantly greater for cancellous screws in osteoporotic models. Stiffness was greater for cancellous screws in standard and osteoporotic models. Cancellous screws have biomechanical advantages over cortical screws when used in metaphyseal bone, implying the ability to both achieve greater compression and resist displacement at the screw-plate interface. Surgeons should preferentially use cancellous over cortical screws in metaphyseal environments where cortical bone is insufficient for fixation.
引用
收藏
页码:E828 / E832
页数:5
相关论文
共 50 条
  • [21] Should we use cortical bone screws for cortical bone trajectory?
    Ueno, Masaki
    Sakai, Rina
    Tanaka, Kensei
    Inoue, Gen
    Uchida, Kentaro
    Imura, Takayuki
    Saito, Wataru
    Nakazawa, Toshiyuki
    Takahira, Naonobu
    Mabuchi, Kiyoshi
    Takaso, Masashi
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (04) : 416 - 421
  • [22] Cortical bone trajectory for lumbar pedicle screws
    Santoni, B. G.
    Hynes, R. A.
    McGilvray, K. C.
    Rodriguez-Canessa, G.
    Lyons, A. S.
    Henson, M. A. W.
    Womack, W. J.
    Puttlitz, C. M.
    SPINE JOURNAL, 2009, 9 (05): : 366 - 373
  • [23] THE PREDICTION OF POSTOPERATIVE COMPRESSION IN CORTICAL BONE SCREWS
    CORDEY, J
    PERREN, SM
    JOURNAL OF BIOMECHANICS, 1980, 13 (09) : 799 - 799
  • [24] In vitro evaluation of screws and suture anchors in metaphyseal bone of the canine tibia
    Robb, JL
    Cook, JL
    Carson, W
    VETERINARY SURGERY, 2005, 34 (05) : 499 - 508
  • [25] Axial compression generated by cortical and cancellous lag screws in the equine distal phalanx
    Johnson, KA
    Smith, FW
    VETERINARY JOURNAL, 2003, 166 (02): : 159 - 163
  • [26] A biomechanical study comparing a raft of 3.5 mm cortical screws with 6.5 mm cancellous screws in depressed tibial plateau fractures
    Patil, Sunit
    Mahon, Andrew
    Green, Sarah
    McMurtry, Ian
    Port, Andrew
    KNEE, 2006, 13 (03): : 231 - 235
  • [27] Mechanical performance of standard and cannulated 4.0 mm cancellous bone screws
    Brown, Greg A.
    McCarthy, Tracey
    Bourgeault, Craig A.
    Callahan, Dennis J.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 581 - 582
  • [28] Ankle Arthrodesis with Three Cancellous Screws
    Khominets, V. V.
    Mikhailov, S., V
    Shakun, D. A.
    Shumagaziev, S. E.
    Komarov, A., V
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2018, 24 (02): : 117 - 126
  • [29] Torque Control during Bone Insertion of Cortical Screws
    Moldovan, Flaviu
    Bataga, Tiberiu
    13TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2019), 2020, 46 : 484 - 490
  • [30] THE USE OF POWER TOOLS IN THE INSERTION OF CORTICAL BONE SCREWS
    ELLIOTT, D