Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone

被引:19
|
作者
Wang, Tim [1 ]
Boone, Christopher [1 ]
Behn, Anthony W. [1 ]
Ledesma, Justin B. [1 ]
Bishop, Julius A. [1 ]
机构
[1] Stanford Univ, Med Ctr, 450 Broadway St,Pavil C,4th Fl, Palo Alto, CA 94063 USA
关键词
PULLOUT STRENGTH; HOLDING POWER; TORQUE; FIXATION; MODELS;
D O I
10.3928/01477447-20160509-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Cancellous screws are designed to optimize fixation in metaphyseal bone environments; however, certain clinical situations may require the substitution of cortical screws for use in cancellous bone, such as anatomic constraints, fragment size, or available instrumentation. This study compares the biomechanical properties of commercially available cortical and cancellous screw designs in a synthetic model representing various bone densities. Commercially available, fully threaded, 4.0-mm outer-diameter cortical and cancellous screws were tested in terms of pullout strength and maximum insertion torque in standard-density and osteoporotic cancellous bone models. Pullout strength and maximum insertion torque were both found to be greater for cancellous screws than cortical screws in all synthetic densities tested. The magnitude of difference in pullout strength between cortical and cancellous screws increased with decreasing synthetic bone density. Screw displacement prior to failure and total energy absorbed during pullout strength testing were also significantly greater for cancellous screws in osteoporotic models. Stiffness was greater for cancellous screws in standard and osteoporotic models. Cancellous screws have biomechanical advantages over cortical screws when used in metaphyseal bone, implying the ability to both achieve greater compression and resist displacement at the screw-plate interface. Surgeons should preferentially use cancellous over cortical screws in metaphyseal environments where cortical bone is insufficient for fixation.
引用
收藏
页码:E828 / E832
页数:5
相关论文
共 50 条
  • [1] THE HOLDING STRENGTH OF CANNULATED SCREWS COMPARED WITH SOLID CORE SCREWS IN CORTICAL AND CANCELLOUS BONE
    LEGGON, R
    LINDSEY, RW
    DOHERTY, BJ
    ALEXANDER, J
    NOBLE, P
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (05) : 450 - 457
  • [2] Pullout strength of 2.0 mm cancellous and cortical screws in synthetic bone
    Moser, John E.
    Kunkel, Kevin A. R.
    Gerard, Patrick D.
    VETERINARY SURGERY, 2017, 46 (08) : 1110 - 1115
  • [3] CORTICAL BONE SCREWS
    MARSTON, RA
    WILLIAMS, RL
    MOYES, ST
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (03): : 206 - 206
  • [4] COMPARISON OF CORTICAL AND CANCELLOUS SCREWS FOR STERNAL FIXATION
    Christakis, Alexander
    Dieselman, John
    Ahn, Jonathan
    Sandefer, Andrew
    Psoinos, Charles
    Ignotz, Ronald
    Lalikos, Janice
    Dunn, Raymond
    Billiar, Kristen
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 757 - 758
  • [5] Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    Seebeck, J
    Goldhahn, J
    Städele, H
    Messmer, P
    Morlock, MM
    Schneider, E
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1237 - 1242
  • [6] Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone
    Lee, Jae Hyup
    Nam, Hwa
    Ryu, Hyun-Seung
    Seo, Jun-Hyuk
    Chang, Bong-Soon
    Lee, Choon-Ki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (03) : 291 - 297
  • [7] The reinforcement of cancellous bone screws with calcium phosphate cement
    Mermelstein, LE
    Chow, LC
    Friedman, C
    Crisco, JJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (01) : 15 - 20
  • [8] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [9] Factors affecting the pullout strength of cancellous bone screws
    Chapman, J.R.
    Harrington, R.M.
    Lee, K.M.
    Anderson, P.A.
    Tencer, A.F.
    Kowalski, D.
    Journal of Biomechanical Engineering, 1996, 118 (03): : 391 - 398
  • [10] Pullout strengths of cannulated and noncannulated cancellous bone screws
    Thompson, JD
    Benjamin, JB
    Szivek, JA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (341) : 241 - 249