Smart polygeneration grids: experimental performance curves of different prime movers

被引:44
作者
Ferrari, Mario L. [1 ]
Traverso, Alberto [1 ]
Massardo, Aristide F. [1 ]
机构
[1] Univ Genoa, DIME, TPG, I-16126 Genoa, Italy
关键词
Measured performance curves; Smart grids; Polygeneration; Trigeneration; Test rig; POWER-GENERATION; HYBRID SYSTEMS; OPTIMAL-DESIGN; GAS-TURBINES; FUEL; PLANTS; MICROTURBINE; INTEGRATION; MANAGEMENT; HEAT;
D O I
10.1016/j.apenergy.2015.10.144
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper shows the performance curves obtained with an experimental campaign on the following different prime movers: a 100 kW microturbine, a 20 kW internal combustion engine, a 450 kW SOFC-based hybrid system and a 100 kW absorption chiller. While the size related to the microturbine and the engine are actual electrical power values, the hybrid system size is an electrical virtual power (an emulator rig was used for this plant) and the chiller value is a cooling thermal power. These experimental results were obtained with a smart polygeneration facility installed in the Innovative Energy Systems Laboratory by the Thermochemical Power Group of the University of Genoa. This facility was designed to perform tests on smart grids equipped with different generation technologies to develop and improve innovative control and optimization tools. The performance curves were obtained with two different approaches: tests on real prime movers (for the microturbine, the engine and the chiller) or measurements on an emulator rig (for the hybrid system). In this second case, the tests were carried out using an experimental facility based on the coupling of a second microturbine with a modular vessel. A real-time simulation software was used for components not physically present in the experimental plant. These results are a significant improvement in comparison with the available data, because experimental results are presented for different prime movers in different operative conditions (both design and part-load operations). Moreover, since both manufacturers and users are not usually able to control air inlet temperature, special attention was devoted to the ambient temperature impact on the 100 kW microturbine because this property has a strong influence on the performance of this machine. For this reason, empirical correlations on the ambient temperature effect were obtained from the experiments with the objective to perform an easy implementation of the optimization tools. Experimental performance curves (including several off-design conditions) are essential for smart grid management because (if they are implemented in optimization tools) they allow to find real optimal solutions (while tools based on linear or calculated correlations can obtain results affected by significant errors). (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:622 / 630
页数:9
相关论文
共 43 条
  • [1] Development, validation and application of a fixed district heating model structure that requires small amounts of input data
    Aberg, Magnus
    Widen, Joakim
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 74 - 85
  • [2] Externally fired gas turbine technology: A review
    Al-attab, K. A.
    Zainal, Z. A.
    [J]. APPLIED ENERGY, 2015, 138 : 474 - 487
  • [3] Development of Anode Gas Recycle System Using Ejector for 1 kW Solid Oxide Fuel Cell
    Baba, Soumei
    Kobayashi, Nariyoshi
    Takahashi, Sanyo
    Hirano, Satoshi
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2015, 137 (02):
  • [4] Incorporating available micro gas turbines and fuel cell: Matching considerations and performance evaluation
    Bakalis, Diamantis P.
    Stamatis, Anastassios G.
    [J]. APPLIED ENERGY, 2013, 103 : 607 - 617
  • [5] Sustainable energy systems: Role of optimization modeling techniques in power generation and supply-A review
    Bazmi, Aqeel Ahmed
    Zahedi, Gholamreza
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (08) : 3480 - 3500
  • [6] Emulator Rig for SOFC Hybrid Systems: Temperature and Power Control with a Real-Time Software
    Caratozzolo, F.
    Ferrari, M. L.
    Traverso, A.
    Massardo, A. F.
    [J]. FUEL CELLS, 2013, 13 (06) : 1123 - 1130
  • [7] Microturbogas cogeneration systems for distributed generation: Effects of ambient temperature on global performance and components' behavior
    Caresana, F.
    Pelagalli, L.
    Comodi, G.
    Renzi, M.
    [J]. APPLIED ENERGY, 2014, 124 : 17 - 27
  • [8] Integration of absorption cooling systems into micro gas turbine trigeneration systems using biogas: Case study of a sewage treatment plant
    Caries Bruno, Joan
    Ortega-Lopez, Victor
    Coronas, Alberto
    [J]. APPLIED ENERGY, 2009, 86 (06) : 837 - 847
  • [9] State of charge estimation of thermal storages for distributed generation systems
    Cuneo, A.
    Ferrari, M. L.
    Pascenti, M.
    Traverso, A.
    [J]. INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 254 - 257
  • [10] Low-energy district heating in energy-efficient building areas
    Dalla Rosa, A.
    Christensen, J. E.
    [J]. ENERGY, 2011, 36 (12) : 6890 - 6899