Shaping ability of GT™ Rotary Files in simulated resin root canals

被引:20
作者
Calberson, FLG
Deroose, CAJG
Hommez, GMG
Raes, H
De Moor, RJG
机构
[1] State Univ Ghent, State Univ Ghent Hosp, Sch Dent, Dept Operat Dent & Endodontol, B-9000 Ghent, Belgium
[2] State Univ Ghent, Dept Biol, B-9000 Ghent, Belgium
关键词
GT (TM) Rotary Files; nickel-titanium; root canal preparation;
D O I
10.1046/j.1365-2591.2002.00540.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study was to determine the shaping ability of GT(TM) Rotary Files in simulated root canals. Methodology Forty canals with four different shapes in terms of angle (40degrees and 60degrees) and position of curvature (straight section before curve: 8 and 12 mm) were prepared using a crown-down/stepback technique. Pre-operative and post-operative pictures, recorded using an image analysis system, were superimposed and aberrations recorded. Measurements were carried out at 5 different points: at the canal orifice (0); half-way to the orifice in the straight section (HO); the beginning of the curve (BC); the apex of the curve (AC); the endpoint (EP). Results Two instrument fractures occurred and 9 instruments were deformed. Overall, eight zips and one ledge were created. There were significant differences (P < 0.001) for the total width of the canals between the various canal shapes at AC, BC and HO. There were significant differences (P ≤ 0.001) for the amount of resin removed from the outer aspect of the curve at AC, BC and HO; and for the amount of resin removed from the inner aspect of the curve at all five measuring points (O, AC and EP (P < 0.05) and HO and BC (P < 0.001)). Mean transportation was towards the inner aspect of the canal in canals with straight sections of 12 mm regardless the curve angle: towards the outer aspect in canals with straight sections of 8 mm and 40° curves at all the five measuring points, and at AC, BC and HO when the curve was 60°, Conclusions Under the conditions of this study, GT(T)M Rotary Files produced acceptable canal shapes. in narrow and curved canals, the length of the straight section of the canal determines the direction of transportation more than the angle of the curve. In the 60° curves, a high incidence of instrument deformation was found when using the 0.04 tapered instruments.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 17 条
[1]   A COMPARISON OF THE ABILITY OF K-FILES AND HEDSTROM FILES TO SHAPE SIMULATED ROOT CANALS IN RESIN BLOCKS [J].
ALODEH, MHA ;
DUMMER, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1989, 22 (05) :226-235
[2]  
Bryant ST, 1998, INT ENDOD J, V31, P282
[3]   Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals [J].
Bryant, ST ;
Dummer, PMH ;
Pitoni, C ;
Bourba, M ;
Moghal, S .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (03) :155-164
[4]   A METHOD FOR THE CONSTRUCTION OF SIMULATED ROOT CANALS IN CLEAR RESIN BLOCKS [J].
DUMMER, PMH ;
ALODEH, MHA ;
ALOMARI, MAO .
INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (02) :63-66
[5]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[6]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[7]   Shaping ability of three profile rotary instrumentation techniques in simulated resin root canals [J].
Kum, KY ;
Spängberg, L ;
Cha, BY ;
Il-Young, J ;
Seung-Jong, L ;
Chan-Young, L .
JOURNAL OF ENDODONTICS, 2000, 26 (12) :719-723
[8]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[9]  
SCHILDER H, 1974, DENT CLIN N AM, V18, P269
[10]  
SCHILDER H, 1984, PATHWAYS PULP, P175