Magnetic Resonance Assessment of Pulmonary (QP) to Systemic (QS) Flows Using 4D Phase-contrast Imaging: Pilot Study Comparison with Standard Through-plane 2D Phase-contrast Imaging

被引:46
|
作者
Hanneman, Kate [1 ]
Sivagnanam, Milani [1 ]
Nguyen, Elsie T. [1 ]
Wald, Rachel [1 ,2 ]
Greiser, Andreas [3 ]
Crean, Andrew M. [1 ,2 ]
Ley, Sebastian [1 ]
Wintersperger, Bernd J. [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Dept Med Imaging, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Div Cardiol, Toronto, ON, Canada
[3] Siemens AG Healthcare Sect, Erlangen, Germany
关键词
Magnetic resonance imaging; magnetic resonance angiography; heart septal defects; atrial; ventricular; heart defects; congenital; CONGENITAL HEART-DISEASE; TO-RIGHT SHUNT; BLOOD-FLOW; HEALTHY-VOLUNTEERS; GREAT-VESSELS; QUANTIFICATION; MRI; VISUALIZATION; HEMODYNAMICS; CIRCULATION;
D O I
10.1016/j.acra.2014.04.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate four-dimensional (4D) phase-contrast(PC) magnetic resonance (MR) in the evaluation of intracardiac shunts by simultaneous assessment of pulmonary (Q(P)) and systemic (Q(S)) flows in a pilot study and to compare results to through-plane two-dimensional (2D) PC MR. Materials and Methods: Institutional review board approval and written informed consent were obtained. Nineteen patients with suspected intracardiac shunts underwent cardiac MR at 1.5T. Assessments of Q(P) and Q(S) were performed using free-breathing retrospectively gated 2D PC gradient recalled echo (GRE; 1.6 x 1.6 X 5 mm(3)) imaging with one-dimensional through-plane velocity encoding gradient (v(enc) = 150 cm/s) in consecutive measurements for the Main pulmonary artery (MPA) and ascending aorta (M), respectively. A prospectively triggered 4D PC GRE technique (2.4 x 1.8 x 3 mm(3)) with three orthogonal v(enc) directions was also used with volume coverage-of both MPA and AA. Results: Q(P) and Q(S) assessed by 4D PC correlated with 2D PC acquisitions (r = 0.92 and r = 0.67 respectively; P < .0001 for both) but demonstrated significant underestimation of individual flow volumes (-21.9 +/- 12.2 mL; P < .0001 and -10.7 +/- 13.1 mL; P = .0023, respectively). Calculated Q(P):Q(S) ratios demonstrated high correlation (r = 0.78; P < .0001) and no significant differences between 4D PC and 2D PC acquisitions (-0.09 +/- 0.24, P = .14). Image acquisition times for 2D PC assessment of Q(P) and Q(S) Were 2.98 +/- 0.52 and 2.84 +/- 0.50 minutes, respectively (P = .038), whereas time to acquire 4D PC images was significantly longer, 18.75 +/- 4.58 minutes (P < .001). Conclusions: Four-dimeneional PC MR imaging allows for accurate assessment of Q(P):Q(S) ratios in the evaluation of intracardiac shunts while absolute flow volumes demonstrate offsets. Further refinement of the technique with improvement in acquisition times may be required before widespread clinical implementation:
引用
收藏
页码:1002 / 1008
页数:7
相关论文
共 42 条
  • [41] Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
    Peper, Eva S.
    Strijkers, Gustav J.
    Gazzola, Katja
    Potters, Wouter V.
    Motaal, Abdallah G.
    Luirink, Ilse K.
    Hutten, Barbara A.
    Wiegman, Albert
    van Ooij, Pim
    van den Born, Bert-Jan H.
    Nederveen, Aart J.
    Coolen, Bram F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [42] Time-resolved 3-dimensional magnetic resonance phase contrast imaging (4D Flow MRI) analysis of hemodynamics in valve-sparing aortic root repair with an anatomically shaped sinus prosthesis
    Oechtering, Thekla H.
    Hons, Carl F.
    Sieren, Malte
    Hunold, Peter
    Hennemuth, Anja
    Huellebrand, Markus
    Drexl, Johann
    Scharfschwerdt, Michael
    Richardt, Doreen
    Sievers, Hans-Hinrich
    Barkhausen, Joerg
    Frydrychowicz, Alex
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (02) : 418 - +