Magnetic Resonance Assessment of Pulmonary (QP) to Systemic (QS) Flows Using 4D Phase-contrast Imaging: Pilot Study Comparison with Standard Through-plane 2D Phase-contrast Imaging

被引:46
|
作者
Hanneman, Kate [1 ]
Sivagnanam, Milani [1 ]
Nguyen, Elsie T. [1 ]
Wald, Rachel [1 ,2 ]
Greiser, Andreas [3 ]
Crean, Andrew M. [1 ,2 ]
Ley, Sebastian [1 ]
Wintersperger, Bernd J. [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Dept Med Imaging, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Div Cardiol, Toronto, ON, Canada
[3] Siemens AG Healthcare Sect, Erlangen, Germany
关键词
Magnetic resonance imaging; magnetic resonance angiography; heart septal defects; atrial; ventricular; heart defects; congenital; CONGENITAL HEART-DISEASE; TO-RIGHT SHUNT; BLOOD-FLOW; HEALTHY-VOLUNTEERS; GREAT-VESSELS; QUANTIFICATION; MRI; VISUALIZATION; HEMODYNAMICS; CIRCULATION;
D O I
10.1016/j.acra.2014.04.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate four-dimensional (4D) phase-contrast(PC) magnetic resonance (MR) in the evaluation of intracardiac shunts by simultaneous assessment of pulmonary (Q(P)) and systemic (Q(S)) flows in a pilot study and to compare results to through-plane two-dimensional (2D) PC MR. Materials and Methods: Institutional review board approval and written informed consent were obtained. Nineteen patients with suspected intracardiac shunts underwent cardiac MR at 1.5T. Assessments of Q(P) and Q(S) were performed using free-breathing retrospectively gated 2D PC gradient recalled echo (GRE; 1.6 x 1.6 X 5 mm(3)) imaging with one-dimensional through-plane velocity encoding gradient (v(enc) = 150 cm/s) in consecutive measurements for the Main pulmonary artery (MPA) and ascending aorta (M), respectively. A prospectively triggered 4D PC GRE technique (2.4 x 1.8 x 3 mm(3)) with three orthogonal v(enc) directions was also used with volume coverage-of both MPA and AA. Results: Q(P) and Q(S) assessed by 4D PC correlated with 2D PC acquisitions (r = 0.92 and r = 0.67 respectively; P < .0001 for both) but demonstrated significant underestimation of individual flow volumes (-21.9 +/- 12.2 mL; P < .0001 and -10.7 +/- 13.1 mL; P = .0023, respectively). Calculated Q(P):Q(S) ratios demonstrated high correlation (r = 0.78; P < .0001) and no significant differences between 4D PC and 2D PC acquisitions (-0.09 +/- 0.24, P = .14). Image acquisition times for 2D PC assessment of Q(P) and Q(S) Were 2.98 +/- 0.52 and 2.84 +/- 0.50 minutes, respectively (P = .038), whereas time to acquire 4D PC images was significantly longer, 18.75 +/- 4.58 minutes (P < .001). Conclusions: Four-dimeneional PC MR imaging allows for accurate assessment of Q(P):Q(S) ratios in the evaluation of intracardiac shunts while absolute flow volumes demonstrate offsets. Further refinement of the technique with improvement in acquisition times may be required before widespread clinical implementation:
引用
收藏
页码:1002 / 1008
页数:7
相关论文
共 42 条
  • [21] Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging
    Silber, HA
    Ouyang, P
    Bluemke, DA
    Gupta, SN
    Foo, TK
    Lima, JAC
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (02): : H822 - H828
  • [22] Intraaneurysmal flow visualization by using phase-contrast magnetic resonance imaging:: feasibility study based on a geometrically realistic in vitro aneurysm model
    Tateshima, S
    Grinstead, J
    Sinha, S
    Nien, YL
    Murayama, Y
    Villablanca, JP
    Tanishita, K
    Viñuela, F
    JOURNAL OF NEUROSURGERY, 2004, 100 (06) : 1041 - 1048
  • [23] Portal hypertension in patients with cirrhosis: indirect assessment of hepatic venous pressure gradient by measuring azygos flow with 2D-cine phase-contrast magnetic resonance imaging
    Hervé Gouya
    Sophie Grabar
    Olivier Vignaux
    Anastasia Saade
    Stanislas Pol
    Paul Legmann
    Philippe Sogni
    European Radiology, 2016, 26 : 1981 - 1990
  • [24] Low-dose in situ prelocation of protein microcrystals by 2D X-ray phase-contrast imaging for serial crystallography
    Martiel, Isabelle
    Huang, Chia-Ying
    Villanueva-Perez, Pablo
    Panepucci, Ezequiel
    Basu, Shibom
    Caffrey, Martin
    Pedrini, Bill
    Bunk, Oliver
    Stampanoni, Marco
    Wang, Meitian
    IUCRJ, 2020, 7 : 1131 - 1141
  • [25] Investigation of phase-contrast magnetic resonance imaging underestimation of turbulent flow through the aortic valve phantom: experimental and computational study using lattice Boltzmann method
    Fucik, Radek
    Galabov, Radek
    Paus, Petr
    Eichler, Pavel
    Klinkovsky, Jakub
    Straka, Robert
    Tintera, Jaroslav
    Chabiniok, Radomir
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (05) : 649 - 662
  • [26] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Karolina Dorniak
    Einar Heiberg
    Marcin Hellmann
    Dorota Rawicz-Zegrzda
    Maria Wesierska
    Rafal Galaska
    Agnieszka Sabisz
    Edyta Szurowska
    Maria Dudziak
    Erik Hedström
    BMC Cardiovascular Disorders, 16
  • [27] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Dorniak, Karolina
    Heiberg, Einar
    Hellmann, Marcin
    Rawicz-Zegrzda, Dorota
    Wesierska, Maria
    Galaska, Rafal
    Sabisz, Agnieszka
    Szurowska, Edyta
    Dudziak, Maria
    Hedstrom, Erik
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [28] 4D cardiac magnetic resonance imaging, 4D and 2D transthoracic echocardiography: a comparison of in-vivo assessment of ventricular function in rats
    Stegmann, Hedwig
    Baeuerle, Tobias
    Kienle, Katharina
    Dittrich, Sven
    Alkassar, Muhannad
    LABORATORY ANIMALS, 2019, 53 (02) : 169 - 179
  • [29] Lower extremity occlusive disease: Diagnostic imaging with a combination of cardiac-gated 2D phase-contrast and cardiac-gated 2D time-of-flight MRA
    Steffens, JC
    Link, J
    Schwarzenberg, H
    Mueller-Huelsbeck, S
    Brinkmann, G
    Heller, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) : 7 - 12
  • [30] Clinical Evaluation of Left Ventricular Diastolic Function Using Phase-contrast Cine Cardiovascular Magnetic Resonance Imaging: A Comparison With Steady-state Free Precession Cine Cardiovascular Magnetic Resonance Imaging and Echocardiography
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Miyatake, Hiroki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 56 - 63