Magnetic Resonance Assessment of Pulmonary (QP) to Systemic (QS) Flows Using 4D Phase-contrast Imaging: Pilot Study Comparison with Standard Through-plane 2D Phase-contrast Imaging

被引:46
|
作者
Hanneman, Kate [1 ]
Sivagnanam, Milani [1 ]
Nguyen, Elsie T. [1 ]
Wald, Rachel [1 ,2 ]
Greiser, Andreas [3 ]
Crean, Andrew M. [1 ,2 ]
Ley, Sebastian [1 ]
Wintersperger, Bernd J. [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Dept Med Imaging, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto Gen Hosp, Peter Munk Cardiac Ctr,Div Cardiol, Toronto, ON, Canada
[3] Siemens AG Healthcare Sect, Erlangen, Germany
关键词
Magnetic resonance imaging; magnetic resonance angiography; heart septal defects; atrial; ventricular; heart defects; congenital; CONGENITAL HEART-DISEASE; TO-RIGHT SHUNT; BLOOD-FLOW; HEALTHY-VOLUNTEERS; GREAT-VESSELS; QUANTIFICATION; MRI; VISUALIZATION; HEMODYNAMICS; CIRCULATION;
D O I
10.1016/j.acra.2014.04.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate four-dimensional (4D) phase-contrast(PC) magnetic resonance (MR) in the evaluation of intracardiac shunts by simultaneous assessment of pulmonary (Q(P)) and systemic (Q(S)) flows in a pilot study and to compare results to through-plane two-dimensional (2D) PC MR. Materials and Methods: Institutional review board approval and written informed consent were obtained. Nineteen patients with suspected intracardiac shunts underwent cardiac MR at 1.5T. Assessments of Q(P) and Q(S) were performed using free-breathing retrospectively gated 2D PC gradient recalled echo (GRE; 1.6 x 1.6 X 5 mm(3)) imaging with one-dimensional through-plane velocity encoding gradient (v(enc) = 150 cm/s) in consecutive measurements for the Main pulmonary artery (MPA) and ascending aorta (M), respectively. A prospectively triggered 4D PC GRE technique (2.4 x 1.8 x 3 mm(3)) with three orthogonal v(enc) directions was also used with volume coverage-of both MPA and AA. Results: Q(P) and Q(S) assessed by 4D PC correlated with 2D PC acquisitions (r = 0.92 and r = 0.67 respectively; P < .0001 for both) but demonstrated significant underestimation of individual flow volumes (-21.9 +/- 12.2 mL; P < .0001 and -10.7 +/- 13.1 mL; P = .0023, respectively). Calculated Q(P):Q(S) ratios demonstrated high correlation (r = 0.78; P < .0001) and no significant differences between 4D PC and 2D PC acquisitions (-0.09 +/- 0.24, P = .14). Image acquisition times for 2D PC assessment of Q(P) and Q(S) Were 2.98 +/- 0.52 and 2.84 +/- 0.50 minutes, respectively (P = .038), whereas time to acquire 4D PC images was significantly longer, 18.75 +/- 4.58 minutes (P < .001). Conclusions: Four-dimeneional PC MR imaging allows for accurate assessment of Q(P):Q(S) ratios in the evaluation of intracardiac shunts while absolute flow volumes demonstrate offsets. Further refinement of the technique with improvement in acquisition times may be required before widespread clinical implementation:
引用
收藏
页码:1002 / 1008
页数:7
相关论文
共 42 条
  • [1] Carotid Phase-Contrast Magnetic Resonance before Treatment: 4D-Flow versus Standard 2D Imaging
    Secchi, Francesco
    Monti, Caterina Beatrice
    Capra, Davide
    Vitale, Renato
    Mazzaccaro, Daniela
    Conti, Michele
    Jin, Ning
    Giese, Daniel
    Nano, Giovanni
    Sardanelli, Francesco
    Marrocco-Trischitta, Massimiliano M.
    TOMOGRAPHY, 2021, 7 (04) : 513 - 522
  • [2] Noninvasive 4D Flow Characterization in a Stirred Tank via Phase-Contrast Magnetic Resonance Imaging
    Janiga, Gabor
    Stucht, Daniel
    Bordas, Robert
    Temmel, Erik
    Seidel-Morgenstern, Andreas
    Thevenin, Dominique
    Speck, Oliver
    CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (07) : 1370 - 1377
  • [3] Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging
    Yokosawa, S
    Nakamura, M
    Wada, S
    Isoda, H
    Takeda, H
    Yamaguchi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 459 - 467
  • [4] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Gabbour, Maya
    Schnell, Susanne
    Jarvis, Kelly
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    PEDIATRIC RADIOLOGY, 2015, 45 (06) : 804 - 813
  • [5] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Maya Gabbour
    Susanne Schnell
    Kelly Jarvis
    Joshua D. Robinson
    Michael Markl
    Cynthia K. Rigsby
    Pediatric Radiology, 2015, 45 : 804 - 813
  • [6] Measuring Pulsatile Flow in Cerebral Arteries Using 4D Phase-Contrast MR Imaging
    Wahlin, A.
    Ambarki, K.
    Birgander, R.
    Wieben, O.
    Johnson, K. M.
    Malm, J.
    Eklund, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (09) : 1740 - 1745
  • [7] Velocity Measurements in the Middle Cerebral Arteries of Healthy Volunteers Using 3D Radial Phase-Contrast HYPRFlow: Comparison with Transcranial Doppler Sonography and 2D Phase-Contrast MR Imaging
    Chang, W.
    Landgraf, B.
    Johnson, K. M.
    Kecskemeti, S.
    Wu, Y.
    Velikina, J.
    Rowley, H.
    Wieben, O.
    Mistretta, C.
    Turski, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 54 - 59
  • [8] 4D UTE Flow: A Phase-Contrast MRI Technique for Assessment and Visualization of Stenotic Flows
    Kadbi, Mo
    Negahdar, M. J.
    Cha, Jung Won
    Traughber, Melanie
    Martin, Peter
    Stoddard, Marcus F.
    Amini, Amir A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 939 - 950
  • [9] One and a Half Ventricle Repair in Adults: Postoperative Hemodynamic Assessment Using Phase-Contrast Magnetic Resonance Imaging
    Chung, Jin Woo
    Goo, Hyun Woo
    Im, Yu-Mi
    Shin, Hong-Ju
    Jhang, Won Kyoung
    Ko, Jae-Kon
    Yun, Tae-Jin
    ANNALS OF THORACIC SURGERY, 2011, 92 (01) : 193 - 199
  • [10] Hemodynamics in normal cerebral arteries: qualitative comparison of 4D phase-contrast magnetic resonance and image-based computational fluid dynamics
    Cebral, Juan R.
    Putman, Christopher M.
    Alley, Marcus T.
    Hope, Thomas
    Bammer, Roland
    Calamante, Fernando
    JOURNAL OF ENGINEERING MATHEMATICS, 2009, 64 (04) : 367 - 378