Impact of attenuation and scatter correction in SPECT for quantification of cerebral blood flow using 99mTc-ethyl cysteinate dimer

被引:4
作者
Shidahara, M [1 ]
Watabe, H
Kim, KM
Hachiya, T
Sayama, I
Kanno, I
Nakamura, T
Iida, H
机构
[1] Natl Cardiovasc Ctr, Dept Investigat Radiol, Suita, Osaka 5658565, Japan
[2] Radiol Rehabil & Psychiat Ctr, Kyowa 0192413, Japan
[3] Res Inst Brain & Blood Vessels, Dept Nucl Med, Akita 0100874, Japan
[4] Tohoku Univ, Dept Quantum Energy Engn, Sendai, Miyagi 9808579, Japan
关键词
attenuation correction; scatter correction;
D O I
10.1109/TNS.2002.998673
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation and scatter of photons are the main causes that binder the quantification of regional cerebral blood flow (rCBF) value by single photon emission computed tomography (SPECT), using Tc-99m-Ethyl cysteinate dimer (ECD). We investigated the effects of attenuation correction and scatter correction on rCBF values with Tc-99m-ECD SPECT. In particular, the applicability of uniform attenuation maps (mu maps) was evaluated in terms of errors on the estimated CBF values and the optimal threshold levels for extracting brain contours. SPECT scans were performed on seven subjects, in the presence of Tc-99m-ECD. Quantitative K-1 images were computed using the reconstructed images and the input function obtained with the frequent arterial blood sampling method. The images were reconstructed by the ordered subset expectation maximization (OSEM) reconstruction in which uniform and segmented mu maps were used for attenuation correction with and without scatter correction. The transmission-dependent convolution subtraction technique was utilized for scatter correction. Segmented and uniform mu maps were generated from magnetic resonance (MR) images. We also produced uniform mu maps using ECD images obtained at various threshold levels and mu values (0.11, 0.15, and 0.172 cm(-1)). Scatter correction improved the image contrast dramatically. There were no significant differences between K-1 images with attenuation and scatter corrections assuming a uniform mu map (not 0.15 but 0.172 cm(-1)) and those corrected with segmented mu maps for most regions. However, in the former images, values were overestimated for deep structures (e.g., overestimation of 9.5% in the striatum and 7.3% in the central semi oval). This small but significant error was also observed in phantom studies and Monte Carlo simulations. We show that the overestimation using uniform mu maps is due to the weight of the path length in the bone. Absolute K-1 values were sensitive to the threshold level when the edge of the brain was determined from the ECD images, but the variation of the estimated K-1 was +/-9.0% when the optimal threshold level was selected. This study suggests that the use of uniform attenuation mu maps provides reasonable accuracy, despite a small but significant error in deep structure regions, and that uniform mu maps may be provided from the emission data alone in this patient population.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 13 条
  • [1] Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT
    Iida, H
    Narita, Y
    Kado, H
    Kashikura, A
    Sugawara, S
    Shoji, Y
    Kinoshita, T
    Ogawa, T
    Eberl, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (01) : 181 - 189
  • [2] Optimization of regularization of attenuation and scatter-corrected 99mTc cardiac SPECT studies for defect detection using hybrid images
    Narayanan, MV
    King, MA
    Leppo, J
    Dahlberg, S
    Pretorius, PH
    Gifford, HC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 785 - 789
  • [3] Effects of scatter correction on regional distribution of cerebral blood flow using I-123-IMP and SPECT
    Ito, H
    Iida, H
    Kinoshita, T
    Hatazawa, J
    Okudera, T
    Uemura, K
    ANNALS OF NUCLEAR MEDICINE, 1999, 13 (05) : 331 - 336
  • [4] Effects of scatter correction on regional distribution of cerebral blood flow using I-123-IMP and SPECT
    Hiroshi Ito
    Hidehiro Iida
    Toshibumi Kinoshita
    Jun Hatazawa
    Toshio Okudera
    Kazuo Uemura
    Annals of Nuclear Medicine, 1999, 13 : 331 - 336
  • [5] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Bailly, Matthieu
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Ribeiro, Maria Joao
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2560 - 2568
  • [6] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Matthieu Bailly
    Frédérique Thibault
    Maxime Courtehoux
    Gilles Metrard
    Maria Joao Ribeiro
    Journal of Nuclear Cardiology, 2021, 28 : 2560 - 2568
  • [7] Clinical Impact of Nonuniform CT-Based Attenuation Correction in Brain Perfusion SPECT/CT Using 99mTc-ECD
    Farid, Karim
    Petras, Slavomir
    Poullias, Xavier
    Caillat-Vigneron, Nadine
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (06) : E343 - E345
  • [8] Transfer learning‑based attenuation correction in 99mTc-TRODAT-1 SPECT for Parkinson’s disease using realistic simulation and clinical data
    Wenbo Huang
    Han Jiang
    Yu Du
    Haiyan Wang
    Hao Sun
    Guang-Uei Hung
    Greta S. P. Mok
    EJNMMI Physics, 12 (1)
  • [9] Imaging Behind the Plaque: Improved Blood Flow Quantification Using an Iterative Scheme for Active Attenuation Correction
    Plomp, Jelle
    Ghanbarzadeh-Dagheyan, Ashkan
    Versluis, Michel
    Lajoinie, Guillaume
    Jebbink, Erik Groot
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (06) : 984 - 998
  • [10] Reliability and advantages of using non-uniform Chang’s attenuation correction method using a CT-based attenuation coefficient map in 99mTc-GSA SPECT/CT hepatic imaging
    Nakamura Y.
    Tomiguchi S.
    Tanaka M.
    EJNMMI Physics, 2 (1) : 1 - 9