共 50 条
Optimization of b-value distribution for biexponential diffusion-weighted MR imaging of normal prostate
被引:37
|作者:
Jambor, Ivan
[1
,2
,3
]
Merisaari, Harri
[4
,5
]
Aronen, Hannu J.
[1
,6
]
Jarvinen, Jukka
[1
,6
]
Saunavaara, Jani
[6
]
Kauko, Tommi
[7
]
Borra, Ronald
[1
,6
]
Pesola, Marko
[1
]
机构:
[1] Univ Turku, Dept Diagnost Radiol, FI-20521 Turku, Finland
[2] Comenius Univ, Dept Radiol 2, Bratislava, Slovakia
[3] St Elisabeth Oncol Inst, Bratislava, Slovakia
[4] Univ Turku, Turku PET Ctr, FI-20521 Turku, Finland
[5] Univ Turku, Dept Informat Technol, FI-20521 Turku, Finland
[6] Turku Univ Hosp, Med Imaging Ctr Southwest Finland, FIN-20520 Turku, Finland
[7] Univ Turku, Dept Biostat, FI-20521 Turku, Finland
关键词:
normal prostate;
diffusion-weighted imaging;
MRI;
Shrout-Fleiss analysis;
Monte-Carlo simulations;
CANCER;
NOISE;
COEFFICIENTS;
PERFUSION;
WATER;
AGGRESSIVENESS;
IMAGES;
D O I:
10.1002/jmri.24271
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose To determine the optimal b-value distribution for biexponential diffusion-weighted imaging (DWI) of normal prostate using both a computer modeling approach and in vivo measurements. Materials and Methods Optimal b-value distributions for the fit of three parameters (fast diffusion Df, slow diffusion Ds, and fraction of fast diffusion f) were determined using Monte-Carlo simulations. The optimal b-value distribution was calculated using four individual optimization methods. Eight healthy volunteers underwent four repeated 3 Tesla prostate DWI scans using both 16 equally distributed b-values and an optimized b-value distribution obtained from the simulations. The b-value distributions were compared in terms of measurement reliability and repeatability using Shrout-Fleiss analysis. Results Using low noise levels, the optimal b-value distribution formed three separate clusters at low (0-400 s/mm(2)), mid-range (650-1200 s/mm(2)), and high b-values (1700-2000 s/mm(2)). Higher noise levels resulted into less pronounced clustering of b-values. The clustered optimized b-value distribution demonstrated better measurement reliability and repeatability in Shrout-Fleiss analysis compared with 16 equally distributed b-values. Conclusion The optimal b-value distribution was found to be a clustered distribution with b-values concentrated in the low, mid, and high ranges and was shown to improve the estimation quality of biexponential DWI parameters of in vivo experiments. J. Magn. Reson. Imaging 2014;39:1213-1222. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1213 / 1222
页数:10
相关论文