Simulation of Hp(10) and effective dose received by the medical staff in interventional radiology procedures

被引:16
作者
Ferrari, P. [1 ]
Becker, F. [2 ]
Jovanovic, Z. [3 ]
Khan, S. [4 ]
Bakhanova, E. [5 ]
Principi, S. [6 ]
Kristic, D. [3 ]
Pierotti, L. [7 ]
Mariotti, F. [1 ]
Faj, D. [8 ]
Turk, T. [8 ,9 ]
Nikezic, D. [3 ]
Bertolini, M. [10 ]
机构
[1] ENEA IRP, Radiat Protect Inst, 4 Via Martini di Monte Sole, I-40129 Bologna, Italy
[2] Karlsruhe Inst Technol, Inst Nucl Waste Disposal, Hermann von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafen, Germany
[3] Univ Kragujevac, Fac Sci, R Domanov 12, Kragujevac 34000, Serbia
[4] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[5] Natl Res Ctr Radiat Med, Melnikova St 53, UA-04050 Kiev, Ukraine
[6] Biomed Engn Dept, 8701 W Watertown Plank Rd, Milwaukee, WI USA
[7] AOSP S Orsola Malpighi Hosp, Via Massarenti 9, I-40138 Bologna, BO, Italy
[8] Univ Osijek UNIOS, Fac Med, Josipa Huttlera 4, HR-31000 Osijek, Croatia
[9] Univ Hosp Osijek, Josipa Huttlera 4, HR-31000 Osijek, Croatia
[10] AUSL Reggio Emilia IRCCS, Viale Risorgimento 80, I-42123 Reggio Emilia, RE, Italy
关键词
interventional radiology; H-p(10); effective dose; medical staff exposure; Monte Carlo simualtions; anthropomorphic model; MONTE-CARLO CALCULATIONS; PATIENT; RADIATION; EYE; EXPOSURE; OPERATOR; HOSPITALS; EXTREMITY; DOSIMETRY; HEIGHT;
D O I
10.1088/1361-6498/ab2c42
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Interventional radiology and cardiology are widespread employed techniques for diagnosis and treatment of several pathologies because they avoid the majority of the side-effects associated with surgical treatments, but are known to increase the radiation exposure to patient and operators. In recent years many studies treated the exposure of the operators performing cardiological procedures. The aim of this work is to study the exposure condition of the medical staff in some selected interventional radiology procedures. The Monte Carlo simulations have been employed with anthropomorphic mathematical phantoms reproducing the irradiation scenario of the medical staff with two operators and the patient. A personal dosemeter, put on apron, was modelled for comparison with measurements performed in hospitals, done with electronic dosemeters, in a reduced number of interventional radiology practices. Within the limits associated to the use of numerical anthropomorphic models to mimic a complex interventional procedure, the personal dose equivalent, H-p(10), was evaluated and normalised to the simulated Kerma-Area Product, KAP, value, indeed the effective dose has been calculated. The H-p(10)/KAP(value) of the first operator is about 10 mu Sv/Gy.cm(2), when ceiling shielding is not used. This value is calculated on the trunk and it varies of +/-30% moving the dosemeter to the waist or to the neck. The effective dose, normalised to the KAP value, varies between 0.03 and 0.4 mu Sv/Gy.cm(2). Considering all the unavoidable approximation of this kind of investigations, the comparisons with hospital measurement and literature data showed a good agreement allowing to use of the present results for dosimetric characterisation of interventional radiology procedures.
引用
收藏
页码:809 / 824
页数:16
相关论文
共 34 条
  • [1] ASSESSMENT OF THE OCCUPATIONAL EXPOSURE IN REAL TIME DURING INTERVENTIONAL CARDIOLOGY PROCEDURES
    Baptista, M.
    Figueira, C.
    Teles, P.
    Cardoso, G.
    Zankl, M.
    Vaz, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 304 - 309
  • [2] Briesmeister J.F., 1997, ALAMOS NATL LAB REPO
  • [3] MONTE CARLO CALCULATIONS ON EXTREMITY AND EYE LENS DOSIMETRY FOR MEDICAL STAFF AT INTERVENTIONAL RADIOLOGY PROCEDURES
    Carinou, E.
    Ferrari, P.
    Koukorava, C.
    Krim, S.
    Struelens, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 492 - 496
  • [4] Personal dose monitoring in hospitals: Global assessment, critical applications and future needs
    Covens, P.
    Berus, D.
    Buls, N.
    Clerinx, P.
    Vanhavere, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 124 (03) : 250 - 259
  • [5] EXTREMITY AND EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY PROCEDURES: FIRST RESULTS OF THE ORAMED PROJECT
    Domienik, J.
    Brodecki, M.
    Carinou, E.
    Donadille, L.
    Jankowski, J.
    Koukorava, C.
    Krim, S.
    Nikodemova, D.
    Ruiz-Lopez, N.
    Sans-Merce, M.
    Struelens, L.
    Vanhavere, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 442 - 447
  • [6] Reduction in exposure of interventional cardiologists to ionising radiation over a 10-year period
    Faroux, Laurent
    Blanpain, Thierry
    Nazeyrollas, Pierre
    Tassan-Mangina, Sophie
    Heroguelle, Virginie
    Tourneux, Christophe
    Baudin, Florian
    Metz, Damien
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 259 : 57 - 59
  • [7] EURADOS Working Group 12 studies in interventional radiology for medical staff dosimetry
    Ferrari, P.
    Bakhanova, E.
    Becker, F.
    Campani, L.
    Chumak, V
    Jansen, J.
    Jovanovic, Z.
    Khan, S.
    Krstic, D.
    Mariotti, F.
    O'Connor, U.
    Pierotti, L.
    Principi, S.
    Clairand, I
    Knezevic, Z.
    [J]. NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2018, 41 (06):
  • [8] Evaluation of the dose to the patient and medical staff in interventional cardiology employing computational models
    Ferrari, P.
    Venturi, G.
    Gualdrini, G.
    Rossi, P. L.
    Mariselli, M.
    Zannoli, R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 141 (01) : 82 - 85
  • [9] Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures
    Ferrari, Paolo
    Becker, Frank
    Carinou, Eleftheria
    Chumak, Vadim
    Farah, Jad
    Jovanovic, Zoran
    Krstic, Dragana
    Morgun, Artem
    Principi, Sara
    Teles, Pedro
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : 902 - 921
  • [10] ICRU, 1993, 51 ICRU