All-Polyethylene versus Metal-Backed Tibial Components in Total Knee Arthroplasty

被引:6
作者
AbuMoussa, Samuel [1 ]
White, Charles Cody [2 ]
Eichinger, Josef K. [1 ]
Friedman, Richard J. [1 ]
机构
[1] Med Univ South Carolina, Dept Orthopaed & Phys Med, Charleston, SC 29425 USA
[2] Med Univ South Carolina, Coll Med, Charleston, SC 29425 USA
关键词
total Knee Arthroplasty; all-polyethylene tibia; metal-backed tibia; COMPARING EARLY FIXATION; CEMENTED COMPONENTS; RANDOMIZED RSA; FOLLOW-UP; HIP; REVISION; FAILURE; AP;
D O I
10.1055/s-0039-1683979
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
All-polyethylene tibial (APT) implants were incorporated into the initial design of the first total knee arthroplasty (TKA) systems. Since then, a dynamic shift has taken place and metal-backed tibial (MBT) implants have become the gold standard in TKA. This has mostly been due to the theoretical advantages of intraoperative flexibility and improved biomechanics in addition to the heavy influence of device manufacturers. MBT implant comes not only with a higher cost but also with potential for complications such as osteolysis, backside wear, and thinning of the polyethylene insert, which were not previously seen with APT implant. The majority of studies comparing APT and MBT implants have shown no difference in clinical outcomes and survivorship. Newer studies from the past decade have begun highlighting the economic advantages of APT implant, especially in patients undergoing primary, uncomplicated TKA. Use of APT implants in younger patients and those with a body mass index > 35 has not been extensively studied, but the existing literature suggests the use of APT implant in these cohorts to be equally as acceptable. With modern implant design and instrumentation, rising utilization of TKA along with current and future economic strain on health care, the increased use of APT implant could result in massive savings without sacrificing positive patient outcomes.
引用
收藏
页码:714 / 718
页数:5
相关论文
共 24 条
[1]  
APEL DM, 1991, CLIN ORTHOP RELAT R, P243
[2]   STRESS DISTRIBUTIONS IN THE ACETABULAR REGION .2. EFFECTS OF CEMENT THICKNESS AND METAL BACKING OF THE TOTAL HIP ACETABULAR COMPONENT [J].
CARTER, DR ;
VASU, R ;
HARRIS, WH .
JOURNAL OF BIOMECHANICS, 1982, 15 (03) :165-170
[3]   All-Polyethylene Tibial Components in Obese Patients Are Associated With Low Failure at Midterm Followup [J].
Dalury, David F. ;
Tucker, Kimberly K. ;
Kelley, Todd C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :117-124
[4]   FAILURE OF TOTAL KNEE ARTHROPLASTY DUE TO LOOSENING AND DEFORMATION OF TIBIAL COMPONENT [J].
DUCHEYNE, P ;
KAGAN, A ;
LACEY, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :384-391
[5]   The AGC all-polyethylene tibial component: A ten-year clinical evaluation [J].
Faris, PM ;
Ritter, MA ;
Keating, EM ;
Meding, JB ;
Harty, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :489-493
[6]   Excellent survilval of all-polyethylene tibial components in a community joint registry [J].
Gioe, Terence J. ;
Sinner, Penny ;
Mehle, Susan ;
Ma, Wenjun ;
Killeen, Kathleen K. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) :88-92
[7]   The All-Polyethylene Tibial Component in Primary Total Knee Arthroplasty [J].
Gioe, Terence J. ;
Maheshwari, Aditya V. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (02) :478-487
[8]   All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register [J].
Gudnason, Asgeir ;
Hailer, Nils P. ;
W-Dahl, Annette ;
Sundberg, Martin ;
Robertsson, Otto .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (12) :994-999
[9]   UCI TOTAL KNEE REPLACEMENT - A FOLLOW-UP-STUDY [J].
HAMILTON, LR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (05) :740-744
[10]   Fixed or mobile-bearing total knee arthroplasty [J].
Huang C.-H. ;
Liau J.-J. ;
Cheng C.-K. .
Journal of Orthopaedic Surgery and Research, 2 (1)