Ventricular Arrhythmia Inducibility Predicts Subsequent ICD Activation in Nonischemic Cardiomyopathy Patients: A DEFINITE Substudy

被引:26
作者
Daubert, James P. [1 ]
Winters, Stephen L. [4 ]
Subacius, Haris [5 ]
Berger, Ronald D. [3 ]
Ellenbogen, Kenneth A. [2 ]
Taylor, Sarah G. [1 ]
Schaechter, Andi [5 ]
Howard, Adam [5 ]
Kadish, Alan [5 ]
机构
[1] Univ Rochester, Med Ctr, Dept Med, Div Cardiol, Rochester, NY 14642 USA
[2] Virginia Commonwealth Univ, Med Coll Virginia, Dept Med, Richmond, VA 23298 USA
[3] Johns Hopkins Univ Hosp, Baltimore, MD 21287 USA
[4] Morristown Mem Hosp, Morristown, NJ USA
[5] Northwestern Univ, Sch Med, Dept Med, Div Cardiol, Chicago, IL 60611 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷 / 06期
关键词
sudden cardiac death; ICD; electrophysiology clinical; congestive heart failure; ventricular tachycardia; ventricular fibrillation; left ventricular dysfunction; dilated cardiomyopathy; physiopathology; IDIOPATHIC DILATED CARDIOMYOPATHY; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; CORONARY-ARTERY-DISEASE; RISK STRATIFICATION; PROGRAMMED STIMULATION; EJECTION FRACTION; HEART-FAILURE; TACHYCARDIA; DYSFUNCTION; TRIAL;
D O I
10.1111/j.1540-8159.2009.02362.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We evaluated whether electrophysiologic (EP) inducibility predicts the subsequent occurrence of spontaneous ventricular tachycardia (VT) or ventricular fibrillation (VF) in the Defibrillators in Nonischemic Cardiomyopathy Treatment Evaluation (DEFINITE) trial. Background: Inducibility of ventricular arrhythmias has been widely used as a risk marker to select implantable cardioverter defibrillator (ICD) candidates, but is believed not to be predictive in nonischemic cardiomyopathy patients. Methods: In DEFINITE, patients randomized to the ICD arm, but not the conventional arm, underwent noninvasive EP testing via the ICD shortly after ICD implantation using up to three extrastimuli at three cycle lengths plus burst pacing. Inducibility was defined as monomorphic or polymorphic VT or VF lasting 15 seconds. Patients were followed for a median of 29 +/- 14 months (interquartile range = 2-41). An independent committee, blinded to inducibility status, characterized the rhythm triggering ICD shocks. Results: Inducibility, found in 29 of 204 patients (VT in 13, VF in 16), was associated with diabetes (41.4% vs 20.6%, P = 0.014) and a slightly higher ejection fraction (23.2 +/- 5.9 vs 20.5 +/- 5.7, P = 0.021). In follow-up, 34.5% of the inducible group (10 of 29) experienced ICD therapy for VT or VF or arrhythmic death versus 12.0% (21 of 175) noninducible patients (hazard ratio = 2.60, P = 0.014). Conclusions: In DEFINITE patients, inducibility of either VT or VF was associated with an increased likelihood of subsequent ICD therapy for VT or VF, and should be one factor considered in risk stratifying nonischemic cardiomyopathy patients. (PACE 2009; 32:755-761).
引用
收藏
页码:755 / 761
页数:7
相关论文
共 18 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]   Role of nonsustained ventricular tachycardia and programmed ventricular stimulation for risk stratification in patients with idiopathic dilated cardiomyopathy [J].
Becker, R ;
Haass, M ;
Ick, D ;
Krueger, C ;
Bauer, A ;
Senges-Becker, JC ;
Voss, F ;
Hilbel, T ;
Niroomand, F ;
Katus, HA ;
Schoels, W .
BASIC RESEARCH IN CARDIOLOGY, 2003, 98 (04) :259-266
[3]   Differences in mechanisms and outcomes of syncope in patients with coronary disease or idiopathic left ventricular dysfunction as assessed by electrophysiologic testing [J].
Brembilla-Perrot, B ;
Suty-Selton, C ;
Beurrier, D ;
Houriez, P ;
Nippert, M ;
de la Chaise, AT ;
Louis, P ;
Claudon, O ;
Andronache, M ;
Abdelaah, A ;
Sadoul, N ;
Juillière, Y .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (03) :594-601
[4]   DIAGNOSTIC-VALUE OF VENTRICULAR STIMULATION IN PATIENTS WITH IDIOPATHIC DILATED CARDIOMYOPATHY [J].
BREMBILLAPERROT, B ;
DONETTI, J ;
DELACHAISE, AT ;
SADOUL, N ;
ALIOT, E ;
JUILLIERE, Y .
AMERICAN HEART JOURNAL, 1991, 121 (04) :1124-1131
[5]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[6]   Electrophysiologic testing to identify patients with coronary artery disease who are at risk for sudden death [J].
Buxton, AE ;
Lee, KL ;
DiCarlo, L ;
Gold, MR ;
Greer, GS ;
Prystowsky, EN ;
O'Toole, MF ;
Tang, A ;
Fisher, JD ;
Coromilas, J ;
Talajic, M ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (26) :1937-1945
[7]   Relation of ejection fraction and inducible ventricular tachycardia to mode of death in patients with coronary artery disease - An analysis of patients enrolled in the Multicenter Unsustained Tachycardia Trial [J].
Buxton, AE ;
Lee, KL ;
Hafley, GE ;
Wyse, DG ;
Fisher, JD ;
Lehmann, MH ;
Pires, LA ;
Gold, MR ;
Packer, DL ;
Josephson, ME ;
Prystowsky, EN ;
Talajic, MR .
CIRCULATION, 2002, 106 (19) :2466-2472
[8]   Role of implantable cardioverter defibrillators in dilated cardiomyopathy [J].
Cappato, R ;
Negroni, S ;
Bentivegna, S ;
Bianchetti, F ;
Pecora, D ;
Morandi, F ;
Furlanello, F .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (01) :S106-S109
[9]   PROGNOSTIC USEFULNESS OF PROGRAMMED VENTRICULAR STIMULATION IN IDIOPATHIC DILATED CARDIOMYOPATHY WITHOUT SYMPTOMATIC VENTRICULAR ARRHYTHMIAS [J].
DAS, SK ;
MORADY, F ;
DICARLO, L ;
BAERMAN, J ;
KROL, R ;
DEBUITLER, M ;
CREVEY, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (10) :998-1000
[10]   Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients [J].
Daubert, JP ;
Zareba, W ;
Hall, WJ ;
Schuger, C ;
Corsello, A ;
Leon, AR ;
Andrews, ML ;
McNitt, S ;
Huang, DT ;
Moss, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) :98-107