ANALYSIS OF COMPLICATIONS IN PATIENTS TREATED WITH THE X-STOP INTERSPINOUS PROCESS DECOMPRESSION SYSTEM: PROPOSAL FOR A NOVEL ANATOMIC SCORING SYSTEM FOR PATIENT SELECTION AND REVIEW OF THE LITERATURE

被引:75
作者
Barbagallo, Giuseppe M. V. [1 ]
Olindo, Giuseppe [1 ]
Corbino, Leonardo [1 ]
Albanese, Vincenzo [1 ]
机构
[1] Univ Policlin G Rodolico, Dept Neurosurg, Azienda Osped, Catania, Italy
关键词
Complication; Distractor/interspinous device; Lumbar stenosis; Neurogenic claudication; Sandwich phenomenon; Spondylolisthesis; X-Stop; LUMBAR SPINAL STENOSIS; NEUROGENIC INTERMITTENT CLAUDICATION; DEGENERATIVE SPONDYLOLISTHESIS; DISTRACTION DEVICE; PROCESS IMPLANT; MULTICENTER; KINEMATICS; INSERTION;
D O I
10.1227/01.NEU.0000346254.07116.31
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The X-Stop Interspinous Process Decompression System (St. Francis Medical Technologies, Concord, CA) is an interspinous device used with increasing frequency in the treatment of degenerative lumbar spine conditions. To date, limited data are available on complications observed in association with X-Stop procedures, and even less information exists on their underlying causes. The aim of this study was to analyze a series of complications occurring at a single institution and their potential causes and propose an anatomic scoring system that may help to classify patients and prevent complications. METHODS: Sixty-nine patients were treated with the X-Stop. Forty-six single-level and 23 double-level operations (92 devices) were performed according to recommended indications. The mean follow-up duration was 23 months. RESULTS: Eight complications were recorded: 4 device dislocations and 4 spinous process (SP) fractures, including 2 spontaneous fractures of the L4 SP in patients treated at L3-L4 and L4-L5. The following anatomic variants were demonstrated: markedly decreased interspinous distance (kissing spine-like), with concomitant facet joint hypertrophy, a posterior V-shaped interspinous area, limited accessibility of the space between the base and the tip of the SP because of facet joint hypertrophy and variations in the shape of the inferior surface of the cranial SP. CONCLUSION: This is the first study focusing on interspinous distractor complications and the anatomic features of the SP and interspinous areas of the patients, which could potentially be the underlying causes for those complications. The X-Stop can be an effective treatment option, but it is not a panacea for all patients with degenerative lumbar spine conditions. Not only do the clinical indications deserve attention, but also, and most importantly, the patient's anatomic characteristics.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 27 条
[1]   Treatment of neurogenic claudication by interspinous decompression: application of the X STOP device in patients with lumbar degenerative spondylolisthesis [J].
Anderson, Paul A. ;
Tribus, Cliff B. ;
Kitchel, Scott H. .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (06) :463-471
[2]  
BARBAGALLO G, 2007, 7 ANN SAS GLOB S MOT
[3]   KISSING SPINES - FACT OR FANCY [J].
BEKS, JWF .
ACTA NEUROCHIRURGICA, 1989, 100 (3-4) :134-135
[4]   Self-rated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication [J].
Brussee, Paul ;
Hauth, Jakob ;
Donk, Roland D. ;
Verbeek, Andre L. M. ;
Bartels, Ronald H. M. A. .
EUROPEAN SPINE JOURNAL, 2008, 17 (02) :200-203
[5]  
Chiu John C, 2006, Surg Technol Int, V15, P265
[6]   Dynamic interspinous process technology [J].
Christie, SD ;
Song, JK ;
Fessler, RG .
SPINE, 2005, 30 (16) :S73-S78
[7]   The use of an interspinous implant in conjunction with a graded facetectomy procedure [J].
Fuchs, PD ;
Lindsey, DP ;
Hsu, KY ;
Zucherman, JF ;
Yerby, SA .
SPINE, 2005, 30 (11) :1266-1272
[8]   The conservative surgical treatment of lumbar spinal stenosis in the elderly [J].
Gunzburg, R ;
Szpalski, M .
EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) :S176-S180
[9]  
HEIJNEN SAF, 2004, NED TIJDSCHR ORTHOP, V11, P199
[10]   Quality of life of lumbar stenosis-treated patients in whom the X STOP interspinous device was implanted [J].
Hsu, Ken Y. ;
Zucherman, James F. ;
Hartjen, Charles A. ;
Mehalic, Thomas F. ;
Implicito, Dante A. ;
Martin, Michael J. ;
Johnson, Donald R., II ;
Skidmore, Grant A. ;
Vessa, Paul P. ;
Dwyer, James W. ;
Cauthen, Joseph C. ;
Ozuna, Richard M. .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (06) :500-507