Increased prevalence of neural monitoring during thyroidectomy: Global surgical survey

被引:40
|
作者
Feng, Allen L. [1 ]
Puram, Sidharth, V [1 ]
Singer, Michael C. [4 ]
Modi, Rahul [2 ]
Kamani, Dipti [2 ]
Randolph, Gregory W. [2 ,3 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Dept Otolaryngol, Boston, MA 02115 USA
[2] Harvard Med Sch, Massachusetts Eye & Ear, Dept Otolaryngol, Div Thyroid & Parathyroid Endocrine Surg, Boston, MA 02115 USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Surg, Div Surg Oncol, Boston, MA 02115 USA
[4] Henry Ford Hlth Syst, Dept Otolaryngol Head & Neck Surg, Div Thyroid & Parathyroid Surg, Detroit, MI USA
关键词
Intraoperative monitoring; thyroidectomy; thyroid and parathyroid surgery; recurrent laryngeal nerve; RECURRENT LARYNGEAL NERVE; PARATHYROID SURGERY; ASSOCIATION STATEMENT; MANAGEMENT; GUIDELINES; PATTERNS; CANCER; HEAD;
D O I
10.1002/lary.28210
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To investigate intraoperative nerve monitoring (IONM) use among thyroid surgeons. Methods A 25-question survey was used to assess attitudes regarding IONM use. Surveys were sent to surgeons registered to the American Academy of Otolaryngology-Head and Neck Surgery, International Association of Endocrine Surgeons, and American Head and Neck Society. Results Among 1,015 respondents, 83% reported using IONM (65.1% always using IONM and 18.1% reporting selective use). For selective users, a majority reported using IONM for reoperative cases (95.1%) and in cases with preoperative vocal cord paralysis (59.8%). When comparing location, there was a significant difference in IONM implementation (P < 0.001), with 70.4% of North American responders using it ubiquitously compared to 27.4% of non-North American responders. Preoperative laryngeal exam was performed more universally by North American surgeons and more selectively by non-North American surgeons (P < 0.001). Other attitudes toward their implementation and the postoperative laryngeal exam were similar. Surgeons <= 45 years of age and those with <= 15 years of practice used IONM more than their peers (P < 0.001). Thyroid surgery volume, fellowship training, and type of practice had no bearing on IONM use. Conclusion The prevalence of IONM in thyroid and parathyroid surgeries has increased significantly over the past decade, with 83% of surgeons using IONM in some or all cases. Although IONM use may be more ubiquitous in North America, attitudes toward its implementation and pre- and postoperative laryngeal exams are fairly uniform. IONM use is more prevalent among younger surgeons, whereas its use has no correlation with thyroid surgery volume or type of practice. Level of Evidence 4 Laryngoscope, 2019
引用
收藏
页码:1097 / 1104
页数:8
相关论文
共 50 条
  • [1] International Survey on the Identification and Neural Monitoring of the EBSLN During Thyroidectomy
    Barczynski, Marcin
    Randolph, Gregory W.
    Cernea, Claudio
    LARYNGOSCOPE, 2016, 126 (01) : 285 - 291
  • [2] Intraoperative nerve monitoring during thyroidectomy: evaluation of signal loss, prognostic value and surgical strategy
    Gur, E. O.
    Haciyanli, M.
    Karaisli, S.
    Haciyanli, S.
    Acar, E. Kamer T.
    Kumkumoglu, Y.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2019, 101 (08) : 589 - 595
  • [3] Thyroidectomy in the Professional Singer-Neural Monitored Surgical Outcomes
    Randolph, Gregory W.
    Sritharan, Niranjan
    Song, Phil
    Franco, Ramon
    Kamani, Dipti
    Woodson, Gayle
    THYROID, 2015, 25 (06) : 665 - 671
  • [4] A Prospective Study of Electromyographic Amplitude Changes During Intraoperative Neural Monitoring for Open Thyroidectomy
    Lian, Tony
    Leong, David
    Ng, Karl
    Bajenov, Sonya
    Sywak, Mark
    WORLD JOURNAL OF SURGERY, 2023, 47 (08) : 1971 - 1977
  • [5] Thyroidectomy facilitated with Harmonic Caliper and intraoperative neural monitoring in three horses
    Al Naem, M.
    Litzke, L. F.
    Mourad, A. A. G.
    EQUINE VETERINARY EDUCATION, 2023, 35 (01) : E45 - E51
  • [6] Recurrent laryngeal nerve monitoring during thyroidectomy and parathyroidectomy in children
    Legre, M.
    Bois, E.
    Bernard, S.
    Teissier, N.
    Van Den Abbeele, T.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 131
  • [7] Early detection of recurrent laryngeal nerve damage using intraoperative nerve monitoring during thyroidectomy
    Yu, Tian
    Wang, Fei-liang
    Meng, Ling-bing
    Li, Jian-kun
    Miao, Gang
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (01)
  • [8] Drawbacks of neural monitoring troubleshooting algorithms in transoral endoscopic thyroidectomy
    Zhang, Daqi
    Wu, Che-Wei
    Wang, Tie
    Zhao, Yishen
    Kim, Hoon Yub
    Pino, Antonella
    Dionigi, Gianlorenzo
    Sun, Hui
    LANGENBECKS ARCHIVES OF SURGERY, 2021, 406 (07) : 2433 - 2440
  • [9] Drawbacks of neural monitoring troubleshooting algorithms in transoral endoscopic thyroidectomy
    Daqi Zhang
    Che-Wei Wu
    Tie Wang
    Yishen Zhao
    Hoon Yub Kim
    Antonella Pino
    Gianlorenzo Dionigi
    Hui Sun
    Langenbeck's Archives of Surgery, 2021, 406 : 2433 - 2440
  • [10] Contralateral surgery in patients scheduled for total thyroidectomy with initial loss or absence of signal during neural monitoring
    Sitges-Serra, A.
    Gallego-Otaegui, L.
    Fontane, J.
    Trillo, L.
    Lorente-Poch, L.
    Sancho, J.
    BRITISH JOURNAL OF SURGERY, 2019, 106 (04) : 404 - 411