Increased prevalence of neural monitoring during thyroidectomy: Global surgical survey

被引:41
作者
Feng, Allen L. [1 ]
Puram, Sidharth, V [1 ]
Singer, Michael C. [4 ]
Modi, Rahul [2 ]
Kamani, Dipti [2 ]
Randolph, Gregory W. [2 ,3 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Dept Otolaryngol, Boston, MA 02115 USA
[2] Harvard Med Sch, Massachusetts Eye & Ear, Dept Otolaryngol, Div Thyroid & Parathyroid Endocrine Surg, Boston, MA 02115 USA
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Surg, Div Surg Oncol, Boston, MA 02115 USA
[4] Henry Ford Hlth Syst, Dept Otolaryngol Head & Neck Surg, Div Thyroid & Parathyroid Surg, Detroit, MI USA
关键词
Intraoperative monitoring; thyroidectomy; thyroid and parathyroid surgery; recurrent laryngeal nerve; RECURRENT LARYNGEAL NERVE; PARATHYROID SURGERY; ASSOCIATION STATEMENT; MANAGEMENT; GUIDELINES; PATTERNS; CANCER; HEAD;
D O I
10.1002/lary.28210
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective To investigate intraoperative nerve monitoring (IONM) use among thyroid surgeons. Methods A 25-question survey was used to assess attitudes regarding IONM use. Surveys were sent to surgeons registered to the American Academy of Otolaryngology-Head and Neck Surgery, International Association of Endocrine Surgeons, and American Head and Neck Society. Results Among 1,015 respondents, 83% reported using IONM (65.1% always using IONM and 18.1% reporting selective use). For selective users, a majority reported using IONM for reoperative cases (95.1%) and in cases with preoperative vocal cord paralysis (59.8%). When comparing location, there was a significant difference in IONM implementation (P < 0.001), with 70.4% of North American responders using it ubiquitously compared to 27.4% of non-North American responders. Preoperative laryngeal exam was performed more universally by North American surgeons and more selectively by non-North American surgeons (P < 0.001). Other attitudes toward their implementation and the postoperative laryngeal exam were similar. Surgeons <= 45 years of age and those with <= 15 years of practice used IONM more than their peers (P < 0.001). Thyroid surgery volume, fellowship training, and type of practice had no bearing on IONM use. Conclusion The prevalence of IONM in thyroid and parathyroid surgeries has increased significantly over the past decade, with 83% of surgeons using IONM in some or all cases. Although IONM use may be more ubiquitous in North America, attitudes toward its implementation and pre- and postoperative laryngeal exams are fairly uniform. IONM use is more prevalent among younger surgeons, whereas its use has no correlation with thyroid surgery volume or type of practice. Level of Evidence 4 Laryngoscope, 2019
引用
收藏
页码:1097 / 1104
页数:8
相关论文
共 34 条
[1]   Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy [J].
Barczynski, M. ;
Konturek, A. ;
Cichon, S. .
BRITISH JOURNAL OF SURGERY, 2009, 96 (03) :240-246
[2]   External branch of the superior laryngeal nerve monitoring during thyroid and parathyroid surgery: International Neural Monitoring Study Group standards guideline statement [J].
Barczynski, Marcin ;
Randolph, Gregory W. ;
Cernea, Claudio R. ;
Dralle, Henning ;
Dionigi, Gianlorenzo ;
Alesina, Piero F. ;
Mihai, Radu ;
Finck, Camille ;
Lombardi, Davide ;
Hartl, Dana M. ;
Miyauchi, Akira ;
Serpell, Jonathan ;
Snyder, Samuel ;
Volpi, Erivelto ;
Woodson, Gayle ;
Kraimps, Jean Louis ;
Hisham, Abdullah N. .
LARYNGOSCOPE, 2013, 123 :S1-S14
[3]   Risk of recurrent laryngeal nerve palsy in patients undergoing thyroidectomy with and without intraoperative nerve monitoring [J].
Bergenfelz, A. ;
Salem, A. F. ;
Jacobsson, H. ;
Nordenstroem, E. ;
Almquist, M. .
BRITISH JOURNAL OF SURGERY, 2016, 103 (13) :1828-1838
[4]   Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy [J].
Brennan, J ;
Moore, EJ ;
Shuler, KJ .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2001, 124 (05) :537-543
[5]   Clinical Practice Guideline: Improving Voice Outcomes after Thyroid Surgery [J].
Chandrasekhar, Sujana S. ;
Randolph, Gregory W. ;
Seidman, Michael D. ;
Rosenfeld, Richard M. ;
Angelos, Peter ;
Barkmeier-Kraemer, Julie ;
Benninger, Michael S. ;
Blumin, Joel H. ;
Dennis, Gregory ;
Hanks, John ;
Haymart, Megan R. ;
Kloos, Richard T. ;
Seals, Brenda ;
Schreibstein, Jerry M. ;
Thomas, Mack A. ;
Waddington, Carolyn ;
Warren, Barbara ;
Robertson, Peter J. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2013, 148 :S1-S37
[6]   American Thyroid Association Statement on Optimal Surgical Management of Goiter [J].
Chen, Amy Y. ;
Bernet, Victor J. ;
Carty, Sally E. ;
Davies, Terry F. ;
Ganly, Ian ;
Inabnet, William B., III ;
Shaha, Ashok R. .
THYROID, 2014, 24 (02) :181-189
[7]   Protective effect of intraoperative nerve monitoring against recurrent laryngeal nerve injury during re-exploration of the thyroid [J].
Chuang, Yu-Chuan ;
Huang, Shih-Ming .
WORLD JOURNAL OF SURGICAL ONCOLOGY, 2013, 11
[8]   Neck Incision Planning for Total Laryngectomy with Pharyngectomy [J].
Clark, James H. ;
Feng, Allen L. ;
Morton, Katie ;
Agrawal, Nishant ;
Richmon, Jeremy D. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 154 (04) :650-656
[9]   Intraoperative neuromonitoring in thyroid surgery: a point prevalence survey on utilization, management, and documentation in Italy [J].
Dionigi G. ;
Lombardi D. ;
Lombardi C.P. ;
Carcoforo P. ;
Boniardi M. ;
Innaro N. ;
Chiofalo M.G. ;
Cavicchi O. ;
Biondi A. ;
Basile F. ;
Zaccaroni A. ;
Mangano A. ;
Leotta A. ;
Lavazza M. ;
Calò P.G. ;
Nicolosi A. ;
Castelnuovo P. ;
Nicolai P. ;
Pezzullo L. ;
De Toma G. ;
Bellantone R. ;
Sacco R. .
Updates in Surgery, 2014, 66 (4) :269-276
[10]   Laryngeal Force Sensor: Quantifying Extralaryngeal Complications after Suspension Microlaryngoscopy [J].
Feng, Allen L. ;
Song, Phillip C. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (02) :328-334