Development of a High Pressure Xe Ionization Chamber for Environmental Radiation Spectroscopy

被引:0
|
作者
Kim, Han Soo [2 ]
Kim, Yong Kyun [1 ]
Park, Se Hwan [2 ]
Ha, Jang Ho [2 ]
Kim, Jong Kyung [1 ]
Kang, Sang Mook [1 ]
Cho, Seung Yeon [3 ]
Kim, Do Hyun [3 ]
Chung, Eui Kwon [3 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
[2] Korea Atom Energy Res Inst, Taejon, South Korea
[3] Yonsei Univ, Dept Environm Engn, Wonju, South Korea
关键词
high-pressure Xe; ionization chamber; environmental radiation; shadow shielding technique; EGSnrc; Garfield; shielding mesh;
D O I
10.1080/00223131.2008.10875869
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A High Pressure Xenon ionization chamber is a promising radiation detector for environmental radiation measurement due to its radiation hardness, its physical rigidity, and its capability of operation at a high temperature up to about 170 degrees C. A cylindrical high pressure xenon ionization chamber, which was configured with a shielding mesh to improve its energy resolution, was designed on the basis of an electron transfer simulation code (EGSnrc) to extract an optimal density of Xe gas and a thickness of the chamber wall. An electron drift simulation code, Garfield, which was coupled with a Maxwell electric filed calculator, was also employed for the electron drift simulations due to the geometry of the shielding mesh. Shielding inefficiency was also calculated. A spherical ionization chamber was also designed and fabricated to monitor environmental radiation. A noble gas system was constructed to create a noble gas with a high purity and to inject the noble gas Lip to 60 atm. The combination of an oxygen absorbent (Oxisorb), a molecular sieve, and a high temperature getter can minimize the electro-negative impurities, such as the O-2 and N-2 gas, to below about several ppb levels. Preliminary tests such as leakage currents, saturation currents, and gas leak test were performed. The performance of the two fabricated ionization chambers at a low dose rate was tested by using a conventional shadow technique with a NIST certified 33.52 MBq Ra-226 source in the calibration room at KAERI.
引用
收藏
页码:383 / 386
页数:4
相关论文
共 50 条
  • [21] Use of the ionization chamber with high pressure for the study of gamma radiations and neutrons
    Savel, P
    JOURNAL DE PHYSIQUE ET LE RADIUM, 1933, 4 : 609 - 612
  • [22] A NOTE ON A SELF-SEALING INSULATOR FOR A HIGH PRESSURE IONIZATION CHAMBER
    READ, J
    BRITISH JOURNAL OF RADIOLOGY, 1948, 21 (248): : 425 - 426
  • [23] A new method for measuring the response time of the high pressure ionization chamber
    Wang, Zhentao
    Shen, Yixiong
    An, Jigang
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1718 - 1722
  • [24] High vacuum ionization chamber with high spatial resolution for monitoring synchrotron radiation beams
    Kosov, A. V.
    Kuper, E. A.
    Sheromov, M. A.
    JOURNAL OF SURFACE INVESTIGATION-X-RAY SYNCHROTRON AND NEUTRON TECHNIQUES, 2011, 5 (06) : 1063 - 1067
  • [25] High vacuum ionization chamber with high spatial resolution for monitoring synchrotron radiation beams
    A. V. Kosov
    E. A. Kuper
    M. A. Sheromov
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2011, 5 : 1063 - 1067
  • [26] Development of an a grid ionization chamber
    China Institute of Atomic Energy, Beijing 102413, China
    Hedianzixue Yu Tance Jishue, 2006, 3 (331-334):
  • [27] Device to increase the dynamic range of high-pressure ionization chambers used in environmental radiation monitoring
    Balagi, V
    Prasad, KR
    Jakati, RK
    Kataria, SK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (12): : 5062 - 5064
  • [28] RESONANCE IONIZATION SPECTROSCOPY SCHEMES FOR AR, KR AND XE
    PAYNE, MG
    CHEN, CH
    HURST, GS
    KRAMER, SD
    GARRETT, WR
    PINDZOLA, M
    CHEMICAL PHYSICS LETTERS, 1981, 79 (01) : 142 - 148
  • [29] EFFECT OF THE INTENSITY OF EXTERNAL IONIZATION ON CHARACTERISTICS OF HIGH-PRESSURE ELECTRICAL IONIZATION AR-XE LASER
    BARANOV, VV
    DANILYCHEV, VA
    DUDIN, AY
    ZAYARNYI, DA
    ROMANOV, AV
    USTINOVSKII, NN
    KHOLIN, IV
    CHUGUNOV, AY
    ZHURNAL TEKHNICHESKOI FIZIKI, 1988, 58 (11): : 2187 - 2193
  • [30] Virtual Frisch-grid ionization chambers filled with high-pressure Xe
    Bolotnikov, AE
    Austin, R
    Bolozdynya, A
    Richards, J
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS VI, 2004, 5540 : 216 - 224