Performance of clinically available deep learning image reconstruction in computed tomography: a phantom study
被引:21
作者:
Kawashima, Hiroki
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Kawashima, Hiroki
[1
]
Ichikawa, Katsuhiro
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Ichikawa, Katsuhiro
[1
]
Takata, Tadanori
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Takata, Tadanori
[2
]
Mitsui, Wataru
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Mitsui, Wataru
[2
]
Ueta, Hiroshi
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Ueta, Hiroshi
[2
]
Yoneda, Norihide
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Dept Radiol, Grad Sch Med Sci, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Yoneda, Norihide
[3
]
Kobayashi, Satoshi
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, JapanKanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
Kobayashi, Satoshi
[1
]
机构:
[1] Kanazawa Univ, Fac Hlth Sc, Inst Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
[2] Kanazawa Univ Hosp, Radiol Div, Kanazawa, Ishikawa, Japan
[3] Kanazawa Univ, Dept Radiol, Grad Sch Med Sci, Kanazawa, Ishikawa, Japan
Purpose: To assess the physical performance of deep learning image reconstruction (DLIR) compared with those of filtered back projection (FBP) and iterative reconstruction (IR) and to estimate the dose reduction potential of the technique. Approach: A cylindrical water bath phantom with a diameter of 300 mm including two rods composed of acrylic and soft tissue-equivalent material was scanned using a clinical computed tomography (CT) scanner at four dose levels (CT dose index of 20, 15, 10, and 5 mGy). Phantom images were reconstructed using FBP, DLIR, and IR. The in-plane and z axis task transfer functions (TTFs) and in-plane noise power spectrum (NPS) were measured. The dose reduction potential was estimated by evaluating the system performance function calculated from TTF and NPS. The visibilities of a bar pattern phantom placed in the same water bath phantom were compared. Results: The use of DLIR resulted in a notable decrease in noise magnitude. The shift in peak NPS frequency was reduced compared with IR. Preservation of in-plane TTF was superior using DLIR than using IR. The estimated dose reduction potentials of DLIR and IR were 39% to 54% and 19% to 29%, respectively. However, the z axis resolution was decreased with DLIR by 6% to 21% compared with FBP. The bar pattern visibilities were approximately consistent with the TTF results in both planes. Conclusions: The in-plane edge-preserving noise reduction performance of DLIR is superior to that of IR. Moreover, DLIR enables approximately half-dose acquisitions with no deterioration in noise texture in cases that permit some z axis resolution reduction. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE).
机构:
Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Chen, Baiyu
;
Christianson, Olav
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Christianson, Olav
;
Wilson, Joshua M.
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Wilson, Joshua M.
;
Samei, Ehsan
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USA
Duke Univ, Dept Phys, Durham, NC 27705 USA
Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
Duke Univ, Dept Elect & Comp Engn, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
机构:
Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Chen, Baiyu
;
Christianson, Olav
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Christianson, Olav
;
Wilson, Joshua M.
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Wilson, Joshua M.
;
Samei, Ehsan
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
Duke Univ, Dept Radiol, Durham, NC 27705 USA
Duke Univ, Dept Phys, Durham, NC 27705 USA
Duke Univ, Dept Biomed Engn, Durham, NC 27705 USA
Duke Univ, Dept Elect & Comp Engn, Durham, NC 27705 USADuke Univ, Med Phys Grad Program, Durham, NC 27705 USA