The outcome of intra-articular distal radius fractures treated with fragment-specific fixation

被引:55
作者
Benson, Leon S.
Minihane, Keith P.
Stern, Laura D.
Eller, Erik
Seshadri, Roopa
机构
[1] Evanston Northwestern Healthcare, Illinois Bone & Joint Inst, Dept Orthopaed Surg, Glenview, IL 60025 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 08期
关键词
distal radius; fracture; fragment-specific fixation;
D O I
10.1016/j.jhsa.2006.07.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To assess the clinical, radiographic, and functional outcome of treating intra-articular distal radius fractures with fragment-specific fixation. Methods: A retrospective review of 81 patients with 85 intra-articular distal radius fractures who were treated with fragment-specific fixation was performed. Minimum time to follow-up evaluation was 1 year, with a mean time of 32 months. The immediate postoperative films were compared with those taken at the final follow-up evaluation. Radiographs of the uninjured wrist were also obtained at the final follow-up evaluation for comparison. Patients were examined for wrist and finger range of motion, deformity, and grip strength, and they completed a standard Disabilities of the Arm, Shoulder, and Hand outcome survey. Results: According to Gartland and Werley scoring there were 61 excellent and 24 good results. Flexion and extension of the surgically treated wrist at the final follow-up evaluation averaged 85% and 91%, respectively, of the uninjured wrist; grip strength averaged 92% compared with the uninjured side. The average Disabilities of the Arm, Shoulder, and Hand outcome score for the injured wrist was 9. Sixty-two percent of patients achieved a 100 degrees arc of flexion and extension and normal forearm rotation by postoperative week 6. Radiographic alignment was maintained between immediate postoperative and final follow-up films, and there were no cases of symptomatic arthritis at the final follow-up evaluation. Conclusions: Fragment-specific fixation is a reasonable alternative for treating intra-articular fractures of the distal radius. At final follow-up evaluations, patients had good to excellent results with respect to range of motion, grip strength, radiographic alignment, and satisfaction scores. Stable fixation allowed starting active and passive motion of the wrist without compromising postoperative alignment.
引用
收藏
页码:1333 / 1339
页数:7
相关论文
共 26 条
[11]   Fractures of the distal radius treated by internal fixation and early function - A prospective study of 73 consecutive patients [J].
Jakob, M ;
Rikli, DA ;
Regazzoni, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03) :340-344
[12]   Comparative classification for fractures of the distal end of the radius [J].
Jupiter, JB ;
Fernandez, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22 (04) :563-571
[13]   INTRAARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS IN YOUNG-ADULTS [J].
KNIRK, JL ;
JUPITER, JB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :647-659
[14]   Open reduction and internal fixation of unstable distal radius fractures: Results using the trimed fixation system [J].
Konrath, GA ;
Bahler, S .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (08) :578-585
[15]  
MELONE CP, 1984, ORTHOP CLIN N AM, V15, P217
[16]   OPEN REDUCTION AND INTERNAL-FIXATION FOR DISTAL RADIUS FRACTURES [J].
MISSAKIAN, ML ;
COONEY, WP ;
AMADIO, PC ;
GLIDEWELL, HL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (04) :745-755
[17]  
Muller M E., 1990, The Comprehensive Classification of Fractures of Long Bones, P106
[18]   Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient [J].
Orbay, JL ;
Fernandez, DL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (01) :96-102
[19]   EXTERNAL FIXATION OF DISTAL RADIAL FRACTURES - RESULTS AND COMPLICATIONS [J].
SANDERS, RA ;
KEPPEL, FL ;
WALDROP, JI .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (03) :385-391
[20]  
Schumer Evan D, 2005, Tech Hand Up Extrem Surg, V9, P74, DOI 10.1097/01.bth.0000158974.15897.1b