High accuracy method for isotope dilution mass spectrometry with application to the measurement of carbon dioxide

被引:27
作者
Milton, MJT [1 ]
Wang, JA [1 ]
机构
[1] Natl Phys Lab, Analyt Sci Grp, Teddington TW11 0LW, Middx, England
关键词
isotope dilution mass spectrometry (IDMS); two-step IDMS; isotope ratio mass spectrometry; carbon dioxide;
D O I
10.1016/S1387-3806(02)00663-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A new approach to the quantitative analysis by isotope dilution mass spectrometry (IDMS) has been developed that overcomes many of the limitations of established methods. It incorporates additional dilution steps that act as an internal calibration so that an independent isotopic reference material is not required. It avoids the need to measure the isotope ratio of the highly enriched spike directly, and enables the final results to be arranged as a combination of measurements that are largely insensitive to instrumental bias and drift. Consequently, it has the potential to extend the scope of application of IDMS to include analyses for which reference materials with certified isotope ratios are not available or where contamination of the instrument by the highly-enriched spike causes difficulty. The new method has been demonstrated by measuring the mass ratio of an isotopically-enriched sample of carbon dioxide in a natural sample of carbon dioxide with a relative uncertainty of 0.02%. Crown Copyright (C) 2002 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 22 条
[1]  
[Anonymous], 2001, 6142 ISO
[2]   Measuring amount ratios of gas isotopes by two primary methods [J].
Aregbe, Y ;
Valkiers, S ;
Mayer, K ;
De Bievre, P ;
Wessel, RM ;
Alink, A .
METROLOGIA, 1998, 35 (01) :7-16
[3]  
*BIPM IEC IFCC ISO, 1995, GUID EXPR UNC MEAS
[4]   Validation of methylmercury determinations in aquatic systems by alkyl derivatization methods for GC analysis using ICP-IDMS [J].
Demuth, N ;
Heumann, KG .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :4020-4027
[5]   A THEORETICAL STUDY OF USE OF INTERNAL STANDARDS FOR PRECISE ISOTOPIC ANALYSIS BY SURFACE IONIZATION TECHNIQUE .1. GENERAL FIRST-ORDER ALGEBRAIC SOLUTIONS [J].
DODSON, MH .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1963, 40 (06) :289-&
[6]   High accuracy analysis of low level sulfur in diesel fuel by isotope dilution high resolution ICP-MS, using silicon for mass bias correction of natural isotope ratios [J].
Evans, P ;
Wolff-Briche, C ;
Fairman, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :964-969
[7]   REDUCTION OF SYSTEMATIC-ERRORS IN QUANTITATIVE-ANALYSIS BY ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) - AN ITERATIVE METHOD [J].
HENRION, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (12) :657-658
[8]  
Heumann K.G, 1988, INORGANIC MASS SPECT
[9]   Correction of instrumentally produced mass fractionation during isotopic analysis of Fe by thermal ionization mass spectrometry [J].
Johnson, CM ;
Beard, BL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 193 (01) :87-99
[10]   Development of an ICP-HRIDMS method for accurate determination of traces of silicon in biological and clinical samples [J].
Klemens, P ;
Heumann, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (06) :758-763