Metabolic studies of tetrazepam based on electrochemical simulation in comparison to in vivo and in vitro methods

被引:76
作者
Baumann, Anne [1 ]
Lohmann, Wiebke [1 ]
Schubert, Birthe [2 ]
Oberacher, Herbert [2 ]
Karst, Uwe [1 ]
机构
[1] Univ Munster, Inst Inorgan & Analyt Chem, D-48149 Munster, Germany
[2] Innsbruck Med Univ, Inst Legal Med, A-6020 Innsbruck, Austria
关键词
Electrochemistry; Oxidative metabolism; Tetrazepam; Liquid chromatography; Mass spectrometry; TANDEM MASS-SPECTROMETRY; BENZODIAZEPINE ACTIVITIES; DISSOCIATES SEDATION; OXIDATION; DIAZEPAM; URINE;
D O I
10.1016/j.chroma.2009.02.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
During the last 2 years, the knowledge on the metabolic pathway of tetrazepam, a muscle relaxant drug, was expanded by the fact that diazepam was identified as a degradation product of tetrazepam. The present study demonstrates that this metabolic conversion, recently discovered by in vivo studies, can also be predicted on the basis of a purely instrumental method, consisting of an electrochemical cell (EC) coupled to online liquid chromatography (LC) and mass spectrometry (MS). By implementing a new electrochemical cell type into the EC-LC-MS set-up and by an enhanced oxidation potential range up to 2V, one limitation of the electrochemical metabolism simulation, the hydroxylation of alkanes and alkenes, has been overcome. Instead of commonly used flow-through cell with a porous glassy carbon working electrode, a wall-jet cell with exchangeable electrode material was used for this study. Thereby, the entire metabolic pathway of tetrazepam, in particular including the hydroxylation of the tetrazepam cyclohexenyl moiety, was simulated. The electrochemical results were not only compared to microsomal incubations, but also to in vivo experiments, by analysing urine samples from a patient after tetrazepam delivery. For structure elucidation of the detected metabolites, MS/MS experiments were performed. The comparison of electrochemistry to in vitro as well as to in vivo experiments underlines the high potential of electrochemistry as a fast screening tool in the prediction of metabolic transformations in drug development. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3192 / 3198
页数:7
相关论文
共 22 条
  • [1] An update on in vitro test methods in human hepatic drug biotransformation research: pros and cons
    Brandon, EFA
    Raap, CD
    Meijerman, I
    Beijnen, JH
    Schellens, JHM
    [J]. TOXICOLOGY AND APPLIED PHARMACOLOGY, 2003, 189 (03) : 233 - 246
  • [2] UTILITY OF SOLUTION ELECTROCHEMISTRY MASS-SPECTROMETRY FOR INVESTIGATING THE FORMATION AND DETECTION OF BIOLOGICALLY IMPORTANT CONJUGATES OF ACETAMINOPHEN
    GETEK, TA
    KORFMACHER, WA
    MCRAE, TA
    HINSON, JA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 474 (01): : 245 - 256
  • [3] Guengerich FP, 2008, ACTA CHIM SLOV, V55, P7
  • [4] ELECTROCHEMICAL THERMOSPRAY MASS-SPECTROMETRY
    HAMBITZER, G
    HEITBAUM, J
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (06) : 1067 - 1070
  • [5] Jurva U, 2000, RAPID COMMUN MASS SP, V14, P529, DOI 10.1002/(SICI)1097-0231(20000331)14:6<529::AID-RCM904>3.0.CO
  • [6] 2-H
  • [7] KEANE PE, 1988, J PHARMACOL EXP THER, V245, P699
  • [8] KEANE PE, 1988, J PHARMACOL EXP THER, V245, P692
  • [9] Detection of diazepam in urine, hair and preserved oral fluid samples with LC-MS-MS after single and repeated administration of Myolastan® and Valium®
    Laloup, Marleen
    Fernandez, Maria del Mar Ramirez
    Wood, Michelle
    Maes, Viviane
    De Boeck, Gert
    Vanbeckevoort, Yvan
    Samyn, Nele
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (07) : 1545 - 1556
  • [10] Biomimetic modeling of oxidative drug metabolism
    Lohmann, Wiebke
    Karst, Uwe
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) : 79 - 96