An improved patch-based regularization method for PET image reconstruction

被引:6
作者
Gao, Juan [1 ,2 ,3 ,4 ]
Liu, Qiegen [5 ]
Zhou, Chao [6 ]
Zhang, Weiguang [6 ]
Wan, Qian [1 ,2 ,3 ]
Hu, Chenxi [4 ]
Gu, Zheng [7 ]
Liang, Dong [1 ,2 ,3 ]
Liu, Xin [1 ,2 ,3 ]
Yang, Yongfeng [1 ,2 ,3 ]
Zheng, Hairong [1 ,2 ,3 ]
Hu, Zhanli [1 ,2 ,3 ]
Zhang, Na [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Chinese Acad Sci, Key Lab Hlth Informat, Shenzhen, Peoples R China
[3] Key Lab Magnet Resonance & Multimodal Imaging Gua, Shenzhen, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[5] Nanchang Univ, Dept Elect Informat Engn, Nanchang, Peoples R China
[6] Sun Yat Sen Univ, Dept Nucl Med, Canc Ctr, Guangzhou, Peoples R China
[7] Inst Biomed Engn, Shenzhen Bay Lab, Shenzhen, Peoples R China
基金
中国国家自然科学基金;
关键词
Positron emission tomography (PET); image reconstruction; maximum likelihood; low-count; EMISSION; CANCER;
D O I
10.21037/qims-20-19
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Statistical reconstruction methods based on penalized maximum likelihood (PML) are being increasingly used in positron emission tomography (PET) imaging to reduce noise and improve image quality. Wang and Qi proposed a patch-based edge-preserving penalties algorithm that can be implemented in three simple steps: a maximum-likelihood expectation-maximization (MLEM) image update, an image smoothing step, and a pixel-by-pixel image fusion step. The pixel-by-pixel image fusion step, which fuses the MLEM updated image and the smoothed image, involves a trade-off between preserving the fine structural features of an image and suppressing noise. Particularly when reconstructing images from low-count data, this step cannot preserve fine structural features in detail. To better preserve these features and accelerate the algorithm convergence, we proposed to improve the patch-based regularization reconstruction method. Methods: Our improved method involved adding a total variation (TV) regularization step following the MLEM image update in the patch-based algorithm. A feature refinement (FR) step was then used to extract the lost fine structural features from the residual image between the TV regularized image and the fused image based on patch regularization. These structural features would then be added back to the fused image. With the addition of these steps, each iteration of the image should gain more structural information. A brain phantom simulation experiment and a mouse study were conducted to evaluate our proposed improved method. Brain phantom simulation with added noise were used to determine the feasibility of the proposed algorithm and its acceleration of convergence. Data obtained from the mouse study were divided into event count sets to validate the performance of the proposed algorithm when reconstructing images from low-count data. Five criteria were used for quantitative evaluation: signal-to-noise ratio (SNR), covariance (COV), contrast recovery coefficient (CRC), regional relative bias, and relative variance. Results: The bias and variance of the phantom brain image reconstructed using the patch-based method were 0.421 and 5.035, respectively, and this process took 83.637 seconds. The bias and variance of the image reconstructed by the proposed improved method, however, were 0.396 and 4.568, respectively, and this process took 41.851 seconds. This demonstrates that the proposed algorithm accelerated the reconstruction convergence. The CRC of the phantom brain image reconstructed using the patch-based method was iterated 20 times and reached 0.284, compared with the proposed method, which reached 0.446. When using a count of 5,000 K data obtained from the mouse study, both the patch-based method and the proposed method reconstructed images similar to the ground truth image. The intensity of the ground truth image was 88.3, and it was located in the 102nd row and the 116th column. However, when the count was reduced to below 40 K, and the patch-based method was used, image quality was significantly reduced. This effect was not observed when the proposed method was used. When a count of 40 K was used, the image intensity was 58.79 when iterated 100 times by the patch-based method, and it was located in the 102nd row and the 116th column, while the intensity when iterated 50 times by the proposed method was 63.83. This suggests that the proposed method improves image reconstruction from low-count data. Conclusions: This improved method of PET image reconstruction could potentially improve the quality of PET images faster than other methods and also produce better reconstructions from low-count data.
引用
收藏
页数:16
相关论文
共 32 条
[1]   Gap compensation during PET image reconstruction by constrained, total variation minimization [J].
Ahn, Seonmin ;
Kim, Soo Mee ;
Son, Jungah ;
Lee, Dong Soo ;
Lee, Jae Sung .
MEDICAL PHYSICS, 2012, 39 (02) :589-602
[2]   Intramedullary spinal cord metastases and whole body 18F-FDG PET-CT-A case report [J].
Bhatt, Geetika ;
Jain, Angita ;
Bhatt, Aashish ;
Civelek, Ali Cahid .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (03) :530-534
[3]   Site specific measurements of bone formation using [18F] sodium fluoride PET/CT [J].
Blake, Glen M. ;
Puri, Tanuj ;
Siddique, Musib ;
Frost, Michelle L. ;
Moore, Amelia E. B. ;
Fogelman, Ignac .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (01) :47-59
[4]   Primal and Dual Bregman Methods with Application to Optical Nanoscopy [J].
Brune, Christoph ;
Sawatzky, Alex ;
Burger, Martin .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2011, 92 (02) :211-229
[5]   Sparse representation and dictionary learning penalized image reconstruction for positron emission tomography [J].
Chen, Shuhang ;
Liu, Huafeng ;
Shi, Pengcheng ;
Chen, Yunmei .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) :807-823
[6]   A limited-angle CT reconstruction method based on anisotropic TV minimization [J].
Chen, Zhiqiang ;
Jin, Xin ;
Li, Liang ;
Wang, Ge .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07) :2119-2141
[7]  
Deidda D, 2017, IEEE NUCL SCI CONF R
[8]   PENALIZED WEIGHTED LEAST-SQUARES IMAGE-RECONSTRUCTION FOR POSITRON EMISSION TOMOGRAPHY [J].
FESSLER, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :290-300
[9]   Positron emission tomography image reconstruction using feature extraction [J].
Gao, Juan ;
Zhang, Qiyang ;
Liu, Qiegen ;
Zhang, Xuezhu ;
Zhang, Mengxi ;
Yang, Yongfeng ;
Liang, Dong ;
Liu, Xin ;
Zheng, Hairong ;
Hu, Zhanli .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) :949-963
[10]   Preoperative PET/CT score can predict complete resection in advanced epithelial ovarian cancer: a prospective study [J].
Gu, Bingxin ;
Xia, Lingfang ;
Ge, Huijuan ;
Liu, Shuai .
QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) :743-+